MessageIdVersionQualifiersLevelTaskOpcodeKeywordsRecordIdProviderNameProviderIdLogNameProcessIdThreadIdMachineNameUserIdTimeCreatedActivityIdRelatedActivityIdContainerLogMatchedQueryIdsBookmarkLevelDisplayNameOpcodeDisplayNameTaskDisplayNameKeywordsDisplayNamesProperties
The Software Protection service has stopped. 90301638400036028797018963968591Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-02-18T16:27:42Z. Reason: TBL.1638401638440036028797018963968590Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968589Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259144 minutes.103703276840036028797018963968588Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259144)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968587Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968586Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968585Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 4:28:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968584neutron-ovs-agentApplicationhv-osbrick-77622/17/2021 4:26:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968583cinder-volumeApplicationhv-osbrick-77622/17/2021 4:26:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968582nova-computeApplicationhv-osbrick-77622/17/2021 4:26:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808581Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application49003912hv-osbrick-7762S-1-5-182/17/2021 3:59:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968580Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-02-18T15:57:41Z. Reason: TBL.1638401638440036028797018963968579Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968578Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259174 minutes.103703276840036028797018963968577Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968576Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968575Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968574Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:58:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea9c5 Analysis symbol: Rechecking for solution: 0 Report Id: c24ef13c-086b-4ac2-9ffe-3d8c10555a48 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968573Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea8fa Analysis symbol: Rechecking for solution: 0 Report Id: 3d1b3aa6-300b-4790-a9ab-caaaf082f183 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968572Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea82f Analysis symbol: Rechecking for solution: 0 Report Id: c9de9994-10f7-4cb4-ab4c-85057f7984e2 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968571Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea764 Analysis symbol: Rechecking for solution: 0 Report Id: 86ddaa89-4815-4af9-aad4-fd15555181c3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968570Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10faa6b8 Analysis symbol: Rechecking for solution: 0 Report Id: 5377789c-2293-43ee-b107-1a60e2269615 Report Status: 4 Hashed bucket: 100104036028797018963968569Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea679 Analysis symbol: Rechecking for solution: 0 Report Id: 761dd502-2283-4756-903d-099b01729a7f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968568Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x390 Faulting application start time: 0x01d705444ba08e6e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5377789c-2293-43ee-b107-1a60e2269615 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968567Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0472a5fc Analysis symbol: Rechecking for solution: 0 Report Id: 2441109d-ea5b-4477-9737-fe147d1d2a25 Report Status: 4 Hashed bucket: 100104036028797018963968566Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x3d0 Faulting application start time: 0x01d705444b83d8d4 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2441109d-ea5b-4477-9737-fe147d1d2a25 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968565Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea58f Analysis symbol: Rechecking for solution: 0 Report Id: 55fb96c2-14a1-4810-becb-2f853bcd71b8 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968564Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10d6a550 Analysis symbol: Rechecking for solution: 0 Report Id: a51f5aca-629e-40b0-90ea-0d6f629cefa8 Report Status: 4 Hashed bucket: 100104036028797018963968563Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc48 Faulting application start time: 0x01d705444b6a7298 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a51f5aca-629e-40b0-90ea-0d6f629cefa8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968562Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea4d3 Analysis symbol: Rechecking for solution: 0 Report Id: ba032263-9c3a-47dd-b69f-520ce600764f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968561Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13eea4b4 Analysis symbol: Rechecking for solution: 0 Report Id: 645ecead-0ac3-45d2-8ab7-1a1092fbb0ee Report Status: 4 Hashed bucket: 100104036028797018963968560Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1314 Faulting application start time: 0x01d705444b513dd9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 645ecead-0ac3-45d2-8ab7-1a1092fbb0ee Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968559Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea408 Analysis symbol: Rechecking for solution: 0 Report Id: 9d8f14ec-6102-4ef6-b73d-3edd7a1178d1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968558Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05bea3f9 Analysis symbol: Rechecking for solution: 0 Report Id: 9a2f6548-d0a3-4f19-ba4b-deda5314dfba Report Status: 4 Hashed bucket: 100104036028797018963968557Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1064 Faulting application start time: 0x01d705444b3461d8 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9a2f6548-d0a3-4f19-ba4b-deda5314dfba Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968556Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea31e Analysis symbol: Rechecking for solution: 0 Report Id: 1006748e-eeed-464b-a5ea-d1ff734f99c6 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968555Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_096aa33d Analysis symbol: Rechecking for solution: 0 Report Id: 2118c445-5279-4e6a-bce6-d4fb525dbbfd Report Status: 4 Hashed bucket: 100104036028797018963968554Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x588 Faulting application start time: 0x01d705444b199b9e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2118c445-5279-4e6a-bce6-d4fb525dbbfd Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968553Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5ea291 Analysis symbol: Rechecking for solution: 0 Report Id: 0db04799-f1f1-48cc-a8c9-b4201eff7939 Report Status: 4 Hashed bucket: 100104036028797018963968552Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea243 Analysis symbol: Rechecking for solution: 0 Report Id: d5867c93-b84c-461b-8334-a02bfa44b9e5 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968551Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xd18 Faulting application start time: 0x01d705444afdb50f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0db04799-f1f1-48cc-a8c9-b4201eff7939 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968550Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1336a1e5 Analysis symbol: Rechecking for solution: 0 Report Id: eae63ae5-76bc-4e82-98d7-ef8854138999 Report Status: 4 Hashed bucket: 100104036028797018963968549Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x9a4 Faulting application start time: 0x01d705444ae35d1a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: eae63ae5-76bc-4e82-98d7-ef8854138999 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968548Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea188 Analysis symbol: Rechecking for solution: 0 Report Id: 6c10b93b-9cc1-422d-a183-efffa156bc08 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968547Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ef2a12a Analysis symbol: Rechecking for solution: 0 Report Id: 331ef13e-096a-47b0-a2ad-a0eaf454c385 Report Status: 4 Hashed bucket: 100104036028797018963968546Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x394 Faulting application start time: 0x01d705444ac90b0b Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 331ef13e-096a-47b0-a2ad-a0eaf454c385 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968545Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cea0bc Analysis symbol: Rechecking for solution: 0 Report Id: 9108c086-1a6f-4e3c-b026-645c0192f7c8 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968544Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0da6a08e Analysis symbol: Rechecking for solution: 0 Report Id: 2ee7531f-8207-4b08-91da-4ad9126849d3 Report Status: 4 Hashed bucket: 100104036028797018963968543Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x5c0 Faulting application start time: 0x01d705444aaf8da6 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2ee7531f-8207-4b08-91da-4ad9126849d3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968542Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ce9fd2 Analysis symbol: Rechecking for solution: 0 Report Id: f1a17a80-c459-401f-b7d7-c3577c0d2898 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968541Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11f69ff1 Analysis symbol: Rechecking for solution: 0 Report Id: 7bbccc1b-93c7-4c55-9893-d0954aa33a23 Report Status: 4 Hashed bucket: 100104036028797018963968540Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x468 Faulting application start time: 0x01d705444a97e4bf Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7bbccc1b-93c7-4c55-9893-d0954aa33a23 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968539Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10de9f45 Analysis symbol: Rechecking for solution: 0 Report Id: be551a18-dd49-4b0e-b7d2-52dd9c4f5e6a Report Status: 4 Hashed bucket: 100104036028797018963968538Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ce9ee8 Analysis symbol: Rechecking for solution: 0 Report Id: c5eba1e2-9b51-4631-b7fa-31cf7d4ccaec Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968537Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe40 Faulting application start time: 0x01d705444a7f32be Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: be551a18-dd49-4b0e-b7d2-52dd9c4f5e6a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968536Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_016a9e9a Analysis symbol: Rechecking for solution: 0 Report Id: eb946328-697e-4dc3-92ef-a5724c74c8a1 Report Status: 4 Hashed bucket: 100104036028797018963968535Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x103c Faulting application start time: 0x01d705444a64521d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: eb946328-697e-4dc3-92ef-a5724c74c8a1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968534Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ce9dfd Analysis symbol: Rechecking for solution: 0 Report Id: 265d1a11-9760-45e3-97e5-a8bf410b8479 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968533Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13e69dfd Analysis symbol: Rechecking for solution: 0 Report Id: 40d27dfc-103a-4856-84ba-3c4e8860ac69 Report Status: 4 Hashed bucket: 100104036028797018963968532Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13bc Faulting application start time: 0x01d705444a4c32ea Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 40d27dfc-103a-4856-84ba-3c4e8860ac69 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968531Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08ee9d71 Analysis symbol: Rechecking for solution: 0 Report Id: 2e048f7b-738f-4f35-a5d6-aa0b046bf049 Report Status: 4 Hashed bucket: 100104036028797018963968530Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ce9d42 Analysis symbol: Rechecking for solution: 0 Report Id: 597efe52-1e5b-4421-9d26-5c126a064edf Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968529Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12c4 Faulting application start time: 0x01d705444a340bae Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2e048f7b-738f-4f35-a5d6-aa0b046bf049 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968528Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_033a9cb5 Analysis symbol: Rechecking for solution: 0 Report Id: 5846ebdb-d6b3-4e00-859b-0aeb0f115b2b Report Status: 4 Hashed bucket: 100104036028797018963968527Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ce9c57 Analysis symbol: Rechecking for solution: 0 Report Id: 0a12f0ac-b6eb-48a5-a1da-7ad557e2b5de Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968526Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1050 Faulting application start time: 0x01d705444a19d319 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5846ebdb-d6b3-4e00-859b-0aeb0f115b2b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968525Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_130e9c29 Analysis symbol: Rechecking for solution: 0 Report Id: a78d71ea-bc20-4d22-a240-393478866f71 Report Status: 4 Hashed bucket: 100104036028797018963968524Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1090 Faulting application start time: 0x01d705444a02bdaf Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a78d71ea-bc20-4d22-a240-393478866f71 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968523Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06769b8c Analysis symbol: Rechecking for solution: 0 Report Id: 23f3e275-7700-492a-ae3f-ad4fa04beb3d Report Status: 4 Hashed bucket: 100104036028797018963968522Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x370 Faulting application start time: 0x01d7054449eb580c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 23f3e275-7700-492a-ae3f-ad4fa04beb3d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968521Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c7a9ae0 Analysis symbol: Rechecking for solution: 0 Report Id: 28cd78de-b5bb-4393-ba71-0dda5e59b691 Report Status: 4 Hashed bucket: 100104036028797018963968520Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe7c Faulting application start time: 0x01d7054449d17bef Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 28cd78de-b5bb-4393-ba71-0dda5e59b691 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968519Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11fa9a35 Analysis symbol: Rechecking for solution: 0 Report Id: 468775f0-2c26-4771-91f9-09b363ceed7b Report Status: 4 Hashed bucket: 100104036028797018963968518Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xa14 Faulting application start time: 0x01d7054449b62568 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 468775f0-2c26-4771-91f9-09b363ceed7b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968517Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_104a9989 Analysis symbol: Rechecking for solution: 0 Report Id: c24ef13c-086b-4ac2-9ffe-3d8c10555a48 Report Status: 4 Hashed bucket: 100104036028797018963968516Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x121c Faulting application start time: 0x01d70544499dc792 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c24ef13c-086b-4ac2-9ffe-3d8c10555a48 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968515Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e98dd Analysis symbol: Rechecking for solution: 0 Report Id: 4eb9bb3d-1e6f-424a-a981-6ebd9a361a1e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968514Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_112e98dd Analysis symbol: Rechecking for solution: 0 Report Id: 3d1b3aa6-300b-4790-a9ab-caaaf082f183 Report Status: 4 Hashed bucket: 100104036028797018963968513Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1110 Faulting application start time: 0x01d70544498261ca Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 3d1b3aa6-300b-4790-a9ab-caaaf082f183 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968512Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:08 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0dae9831 Analysis symbol: Rechecking for solution: 0 Report Id: c9de9994-10f7-4cb4-ab4c-85057f7984e2 Report Status: 4 Hashed bucket: 100104036028797018963968511Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e9802 Analysis symbol: Rechecking for solution: 0 Report Id: 81bd2b6d-ecc0-46e7-b87f-6de29af489b7 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968510Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x634 Faulting application start time: 0x01d705444968c5db Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c9de9994-10f7-4cb4-ab4c-85057f7984e2 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968509Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_109e9795 Analysis symbol: Rechecking for solution: 0 Report Id: 86ddaa89-4815-4af9-aad4-fd15555181c3 Report Status: 4 Hashed bucket: 100104036028797018963968508Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xdd8 Faulting application start time: 0x01d7054449506d81 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 86ddaa89-4815-4af9-aad4-fd15555181c3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968507Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e9708 Analysis symbol: Rechecking for solution: 0 Report Id: 0eed7e8f-b546-4fdd-afb9-469565d0fd1f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968506Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_138696e9 Analysis symbol: Rechecking for solution: 0 Report Id: 761dd502-2283-4756-903d-099b01729a7f Report Status: 4 Hashed bucket: 100104036028797018963968505Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x928 Faulting application start time: 0x01d70544493630ec Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 761dd502-2283-4756-903d-099b01729a7f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968504Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e962d Analysis symbol: Rechecking for solution: 0 Report Id: 93d9bf99-ca8e-4c41-8052-ed41a5c60b2a Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968503Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03de962d Analysis symbol: Rechecking for solution: 0 Report Id: 55fb96c2-14a1-4810-becb-2f853bcd71b8 Report Status: 4 Hashed bucket: 100104036028797018963968502Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1320 Faulting application start time: 0x01d70544491a45e1 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 55fb96c2-14a1-4810-becb-2f853bcd71b8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968501Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_135a9591 Analysis symbol: Rechecking for solution: 0 Report Id: ba032263-9c3a-47dd-b69f-520ce600764f Report Status: 4 Hashed bucket: 100104036028797018963968500Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e9572 Analysis symbol: Rechecking for solution: 0 Report Id: 6f426945-a3b4-4c55-97be-1f82c561a551 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968499Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x128c Faulting application start time: 0x01d7054449028cc5 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ba032263-9c3a-47dd-b69f-520ce600764f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968498Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_098694f5 Analysis symbol: Rechecking for solution: 0 Report Id: 9d8f14ec-6102-4ef6-b73d-3edd7a1178d1 Report Status: 4 Hashed bucket: 100104036028797018963968497Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x480 Faulting application start time: 0x01d7054448e94d85 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9d8f14ec-6102-4ef6-b73d-3edd7a1178d1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968496Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e9497 Analysis symbol: Rechecking for solution: 0 Report Id: df0d16cc-46f7-4799-9c84-6808c810cf31 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968495Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bca9439 Analysis symbol: Rechecking for solution: 0 Report Id: 1006748e-eeed-464b-a5ea-d1ff734f99c6 Report Status: 4 Hashed bucket: 100104036028797018963968494Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x508 Faulting application start time: 0x01d7054448cf4b06 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1006748e-eeed-464b-a5ea-d1ff734f99c6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968493Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e93cc Analysis symbol: Rechecking for solution: 0 Report Id: 5978a435-e375-4a36-be5b-613a1b0d01e4 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968492Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05d2939d Analysis symbol: Rechecking for solution: 0 Report Id: d5867c93-b84c-461b-8334-a02bfa44b9e5 Report Status: 4 Hashed bucket: 100104036028797018963968491Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x2a8 Faulting application start time: 0x01d7054448b6a605 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d5867c93-b84c-461b-8334-a02bfa44b9e5 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968490Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e92f1 Analysis symbol: Rechecking for solution: 0 Report Id: 0761f438-055b-4848-88b5-bd43444cf9de Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968489Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13f69301 Analysis symbol: Rechecking for solution: 0 Report Id: 6c10b93b-9cc1-422d-a183-efffa156bc08 Report Status: 4 Hashed bucket: 100104036028797018963968488Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13a0 Faulting application start time: 0x01d70544489b9c8b Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6c10b93b-9cc1-422d-a183-efffa156bc08 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968487Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108e9245 Analysis symbol: Rechecking for solution: 0 Report Id: 9108c086-1a6f-4e3c-b026-645c0192f7c8 Report Status: 4 Hashed bucket: 100104036028797018963968486Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e9207 Analysis symbol: Rechecking for solution: 0 Report Id: 5e26a69e-6447-4d15-9ee2-ac8e82599a0d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968485Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x798 Faulting application start time: 0x01d70544487ecfef Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9108c086-1a6f-4e3c-b026-645c0192f7c8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968484Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_121e918a Analysis symbol: Rechecking for solution: 0 Report Id: f1a17a80-c459-401f-b7d7-c3577c0d2898 Report Status: 4 Hashed bucket: 100104036028797018963968483Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b4e910d Analysis symbol: Rechecking for solution: 0 Report Id: 1b53780a-4303-41b1-9f32-f77b7ce405c7 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968482Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x574 Faulting application start time: 0x01d7054448632c72 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f1a17a80-c459-401f-b7d7-c3577c0d2898 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968481Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c0290de Analysis symbol: Rechecking for solution: 0 Report Id: c5eba1e2-9b51-4631-b7fa-31cf7d4ccaec Report Status: 4 Hashed bucket: 100104036028797018963968480Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13f4 Faulting application start time: 0x01d705444848c333 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c5eba1e2-9b51-4631-b7fa-31cf7d4ccaec Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968479Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f0e9013 Analysis symbol: Rechecking for solution: 0 Report Id: 265d1a11-9760-45e3-97e5-a8bf410b8479 Report Status: 4 Hashed bucket: 100104036028797018963968478Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x454 Faulting application start time: 0x01d70544482d859e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 265d1a11-9760-45e3-97e5-a8bf410b8479 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968477Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_125e8f86 Analysis symbol: Rechecking for solution: 0 Report Id: 597efe52-1e5b-4421-9d26-5c126a064edf Report Status: 4 Hashed bucket: 100104036028797018963968476Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11dc Faulting application start time: 0x01d7054448156618 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 597efe52-1e5b-4421-9d26-5c126a064edf Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968475Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11d28ebb Analysis symbol: Rechecking for solution: 0 Report Id: 0a12f0ac-b6eb-48a5-a1da-7ad557e2b5de Report Status: 4 Hashed bucket: 100104036028797018963968474Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe80 Faulting application start time: 0x01d7054447f9193e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0a12f0ac-b6eb-48a5-a1da-7ad557e2b5de Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968473Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03568e2e Analysis symbol: Rechecking for solution: 0 Report Id: 4eb9bb3d-1e6f-424a-a981-6ebd9a361a1e Report Status: 4 Hashed bucket: 100104036028797018963968472Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x728 Faulting application start time: 0x01d7054447e18d34 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 4eb9bb3d-1e6f-424a-a981-6ebd9a361a1e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968471Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c4a8d92 Analysis symbol: Rechecking for solution: 0 Report Id: b0745fad-4b18-4941-b1c8-5b037a5cb822 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968470Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ea8d92 Analysis symbol: Rechecking for solution: 0 Report Id: 81bd2b6d-ecc0-46e7-b87f-6de29af489b7 Report Status: 4 Hashed bucket: 100104036028797018963968469Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xb64 Faulting application start time: 0x01d7054447ca56e2 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 81bd2b6d-ecc0-46e7-b87f-6de29af489b7 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968468Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06768cf6 Analysis symbol: Rechecking for solution: 0 Report Id: 0eed7e8f-b546-4fdd-afb9-469565d0fd1f Report Status: 4 Hashed bucket: 100104036028797018963968467Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x65c Faulting application start time: 0x01d7054447b1f3f4 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0eed7e8f-b546-4fdd-afb9-469565d0fd1f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968466Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c7a8c5a Analysis symbol: Rechecking for solution: 0 Report Id: 93d9bf99-ca8e-4c41-8052-ed41a5c60b2a Report Status: 4 Hashed bucket: 100104036028797018963968465Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1060 Faulting application start time: 0x01d705444798ff34 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 93d9bf99-ca8e-4c41-8052-ed41a5c60b2a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968464Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06228bbd Analysis symbol: Rechecking for solution: 0 Report Id: 6f426945-a3b4-4c55-97be-1f82c561a551 Report Status: 4 Hashed bucket: 100104036028797018963968463Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10bc Faulting application start time: 0x01d705444781c157 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6f426945-a3b4-4c55-97be-1f82c561a551 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968462Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2021?-?02?-?17T15:47:58.961593700Z.100010400-9223372036854775808461Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application48243904hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12368b21 Analysis symbol: Rechecking for solution: 0 Report Id: df0d16cc-46f7-4799-9c84-6808c810cf31 Report Status: 4 Hashed bucket: 100104036028797018963968460Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1084 Faulting application start time: 0x01d705444768a810 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: df0d16cc-46f7-4799-9c84-6808c810cf31 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968459Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_120e8a56 Analysis symbol: Rechecking for solution: 0 Report Id: 5978a435-e375-4a36-be5b-613a1b0d01e4 Report Status: 4 Hashed bucket: 100104036028797018963968458Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x438 Faulting application start time: 0x01d70544474cf1f9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5978a435-e375-4a36-be5b-613a1b0d01e4 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968457Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_110289ba Analysis symbol: Rechecking for solution: 0 Report Id: 0761f438-055b-4848-88b5-bd43444cf9de Report Status: 4 Hashed bucket: 100104036028797018963968456Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe90 Faulting application start time: 0x01d70544473591ec Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0761f438-055b-4848-88b5-bd43444cf9de Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968455Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0592892d Analysis symbol: Rechecking for solution: 0 Report Id: 5e26a69e-6447-4d15-9ee2-ac8e82599a0d Report Status: 4 Hashed bucket: 100104036028797018963968454Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13c8 Faulting application start time: 0x01d70544471d9d25 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5e26a69e-6447-4d15-9ee2-ac8e82599a0d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968453Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_096a8891 Analysis symbol: Rechecking for solution: 0 Report Id: 1b53780a-4303-41b1-9f32-f77b7ce405c7 Report Status: 4 Hashed bucket: 100104036028797018963968452Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x704 Faulting application start time: 0x01d7054447069319 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1b53780a-4303-41b1-9f32-f77b7ce405c7 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968451Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_082287f5 Analysis symbol: Rechecking for solution: 0 Report Id: b0745fad-4b18-4941-b1c8-5b037a5cb822 Report Status: 4 Hashed bucket: 100104036028797018963968450Windows Error ReportingApplicationhv-osbrick-77622/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4352.104204036028797018963968449MsiInstallerApplicationhv-osbrick-7762S-1-5-182/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0.103304036028797018963968448MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully.1170704036028797018963968447MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x994 Faulting application start time: 0x01d7054446c29d11 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: b0745fad-4b18-4941-b1c8-5b037a5cb822 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968446Application ErrorApplicationhv-osbrick-77622/17/2021 3:48:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?02?-?17T15:47:58.961593700Z.100000400-9223372036854775808445Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application48244744hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root list with effective date: ?Friday, ?January ?15, ?2021 12:42:37 AM.411100400-9187343239835811840444Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>.410900400-9187343239835811840443Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.410900400-9187343239835811840442Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>.410900400-9187343239835811840441Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>.410900400-9187343239835811840440Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.410900400-9187343239835811840439Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.410900400-9187343239835811840438Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>.410900400-9187343239835811840437Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.410900400-9187343239835811840436Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4352.104004036028797018963968435MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:47:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.409700400-9187343239835811840434Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241756hv-osbrick-77622/17/2021 3:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808433Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application49364120hv-osbrick-7762S-1-5-182/17/2021 3:33:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2021?-?02?-?17T15:33:41.321220600Z.100010400-9223372036854775808432Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47844760hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 1728.104204036028797018963968431MsiInstallerApplicationhv-osbrick-7762S-1-5-182/17/2021 3:33:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968430MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968429MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?02?-?17T15:33:41.321220600Z.100000400-9223372036854775808428Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47844912hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2021?-?02?-?17T15:33:40.786625100Z.100010400-9223372036854775808427Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47844760hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?02?-?17T15:33:40.786625100Z.100000400-9223372036854775808426Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47844544hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 1728.104004036028797018963968425MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 1728.104204036028797018963968424MsiInstallerApplicationhv-osbrick-7762S-1-5-182/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968423MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968422MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 1728.104004036028797018963968421MsiInstallerApplicationhv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:33:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0.103504036028797018963968420MsiInstallerApplicationhv-osbrick-7762S-1-5-182/17/2021 3:33:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?02?-?17T15:32:57.279289600Z.100000400-9223372036854775808419Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application39444044hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:32:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?02?-?17T15:32:57.247225500Z.100000400-9223372036854775808418Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application39444044hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10012/17/2021 3:32:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968417Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:32:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-02-18T15:31:19Z. Reason: TBL.1638401638440036028797018963968416Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:32:19 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.409700400-9187343239835811840415Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241760hv-osbrick-77622/17/2021 3:32:16 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent819704915240036028797018963968414Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/08/16:15:31:49;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968413Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968412Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259200 minutes.103703276840036028797018963968411Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968410Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968409Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
These policies are being excluded since they are only defined with override-only attribute. Policy Names=(Security-SPP-Reserved-EnableNotificationMode) App Id=55c92734-d682-4d71-983e-d6ec3f16059f Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4103301638440036028797018963968408Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100103401638440036028797018963968407Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Validity period has been started. Validity minutes=259200 Grace type=9.103601638440036028797018963968406Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MSA client has been successfully triggered to update the Device License1231101638440036028797018963968405Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f}1230401638440036028797018963968404Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f1230501638440036028797018963968403Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection ended. 2048904915240036028797018963968402Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968401Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check passed. 2048204915240036028797018963968400Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check initiated. 2048104915240036028797018963968399Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection started. 2048804915240036028797018963968398Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS. 106703276840036028797018963968397Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE} License Id=31071f50-f149-4f55-b16d-289319e61baa100401638440036028797018963968396Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC} License Id=02087849-e3ae-4f1c-b918-7ff9b980e702100401638440036028797018963968395Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Acquisition of End User License was successful. Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4101301638400036028797018963968394Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.409700400-9187343239835811840393Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13242308hv-osbrick-77622/17/2021 3:31:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/02/27:15:26:39;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968392Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:31:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968391Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00hv-osbrick-77622/17/2021 3:30:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968390cloudbase-initApplicationhv-osbrick-77622/17/2021 3:29:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968389Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:28:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied. . 15340300-9223372036854775808388Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5842500hv-osbrick-7762S-1-5-21-1067976199-3020732521-2983816633-10002/17/2021 3:28:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7762\Admin' in response to user profile creation. Error code 0x80070005. Access is denied. .604915220036028797018963968387Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00hv-osbrick-77622/17/2021 3:28:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968386cloudbase-initApplicationhv-osbrick-77622/17/2021 3:28:16 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7762\cloudbase-init' . 501638440036028797018963968385Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00hv-osbrick-77622/17/2021 3:28:14 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.409700400-9187343239835811840384Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13241820hv-osbrick-77622/17/2021 3:28:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808383Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5842040hv-osbrick-7762S-1-5-182/17/2021 3:28:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808382Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5841228hv-osbrick-7762S-1-5-182/17/2021 3:28:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Delete for component {D63AA156-D534-4BAC-9BF1-55359CF5EC30} failed, error code is The system cannot find the path specified. . 15340300-9223372036854775808381Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application584792hv-osbrick-7762S-1-5-182/17/2021 3:28:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808380Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5841664hv-osbrick-7762S-1-5-182/17/2021 3:28:09 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968379Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:28:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968378Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:28:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Proof of Purchase installed successfully. ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845101601638440036028797018963968377Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-77622/17/2021 3:28:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog.462501638440036028797018963968376Microsoft-Windows-EventSystem899daace-4868-4295-afcd-9eb8fb497561Application00hv-osbrick-77622/17/2021 3:28:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808375Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5401496WIN-5T344G8GM1HS-1-5-182/17/2021 3:27:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968374Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H2/17/2021 3:27:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Name: Microsoft Hyper-V VSS Writer821204036028797018963968373VSSApplicationWIN-5T344G8GM1H2/17/2021 3:26:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM.411200400-9187343239835811840372Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication17361824WIN-5T344G8GM1H2/17/2021 3:26:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808371Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication540580WIN-5T344G8GM1HS-1-5-182/17/2021 3:26:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808370Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5401608WIN-5T344G8GM1HS-1-5-182/17/2021 3:26:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808369Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5401496WIN-5T344G8GM1HS-1-5-182/17/2021 3:26:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} Writer Name: Shadow Copy Optimization Writer821204036028797018963968368VSSApplicationWIN-5T344G8GM1H2/17/2021 3:26:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4} Writer Name: ASR Writer821204036028797018963968367VSSApplicationWIN-5T344G8GM1H2/17/2021 3:26:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f} Writer Name: COM+ REGDB Writer821204036028797018963968366VSSApplicationWIN-5T344G8GM1H2/17/2021 3:26:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485} Writer Name: Registry Writer821204036028797018963968365VSSApplicationWIN-5T344G8GM1H2/17/2021 3:26:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808364Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9761228WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:13 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required. DETAIL - 9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500: Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security 15300400-9223372036854775808363Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9763432WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The winlogon notification subscriber <SessionEnv> failed a notification event.600103276830036028797018963968362Microsoft-Windows-Winlogondbe9b383-7cf3-4331-91cc-a3cb16a3b538Application00WIN-5T344G8GM1H1/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968361Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448823001638440036028797018963968360Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )] 100301638440036028797018963968359Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining.1230601638440036028797018963968358Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968357Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968356Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Grace period has been started. Grace days=10 Grace type=6.102501638440036028797018963968355Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968354Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The hardware has changed.102403276840036028797018963968353Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Hardware has changed from previous boot. AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4.104001638440036028797018963968352Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968351Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=Sysprep.exe90001638440036028797018963968350Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968349Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00WIN-5T344G8GM1H1/19/2018 9:47:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]