Message | Id | Version | Qualifiers | Level | Task | Opcode | Keywords | RecordId | ProviderName | ProviderId | LogName | ProcessId | ThreadId | MachineName | UserId | TimeCreated | ActivityId | RelatedActivityId | ContainerLog | MatchedQueryIds | Bookmark | LevelDisplayName | OpcodeDisplayName | TaskDisplayName | KeywordsDisplayNames | Properties |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 602 | neutron-ovs-agent | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:24:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 601 | cinder-volume | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:24:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 600 | nova-compute | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:24:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 599 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:16:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-16T06:15:11Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 598 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:16:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 597 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:15:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259174 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 596 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:15:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 595 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:15:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 594 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:15:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 593 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 6:15:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 592 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 956 | 3968 | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 6:10:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a8ab7
Analysis symbol:
Rechecking for solution: 0
Report Id: 78d4ae45-24e8-4f02-b85b-9ecf819ba384
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 591 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:01:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a89ae
Analysis symbol:
Rechecking for solution: 0
Report Id: c54d6cd1-a852-4a68-94ed-f8b391d449e3
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 590 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:01:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a88a4
Analysis symbol:
Rechecking for solution: 0
Report Id: a4472bdb-be81-4d3b-8e7f-63b95435336f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 589 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:01:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a878b
Analysis symbol:
Rechecking for solution: 0
Report Id: 0d862c66-87e2-4777-9f36-74e54701247b
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 588 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:01:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1236397a
Analysis symbol:
Rechecking for solution: 0
Report Id: 8e889c01-4073-4a1d-a9ec-82506d59f812
Report Status: 96
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 587 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:01:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_121253c9
Analysis symbol:
Rechecking for solution: 0
Report Id: 8dfeb696-ff63-4869-9d08-ac352514cde8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 586 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xea0
Faulting application start time: 0x01d7035fee0e32f1
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 8dfeb696-ff63-4869-9d08-ac352514cde8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 585 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c56534c
Analysis symbol:
Rechecking for solution: 0
Report Id: 49a17cec-8ace-4632-92a2-55ae0e37672f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 584 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x4dc
Faulting application start time: 0x01d7035fedfa4619
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 49a17cec-8ace-4632-92a2-55ae0e37672f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 583 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_00a652cf
Analysis symbol:
Rechecking for solution: 0
Report Id: fd6d05c4-b7dc-48b0-8e0e-ca1960d22acb
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 582 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1058
Faulting application start time: 0x01d7035fede69425
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: fd6d05c4-b7dc-48b0-8e0e-ca1960d22acb
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 581 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ca5252
Analysis symbol:
Rechecking for solution: 0
Report Id: fcbcf28b-7c4f-401e-bba4-e7de62352f61
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 580 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x5bc
Faulting application start time: 0x01d7035fedd320cb
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: fcbcf28b-7c4f-401e-bba4-e7de62352f61
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 579 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_118e51d5
Analysis symbol:
Rechecking for solution: 0
Report Id: 4dadaddd-5012-4e9f-89f7-e97e24015e10
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 578 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1120
Faulting application start time: 0x01d7035fedbedb59
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4dadaddd-5012-4e9f-89f7-e97e24015e10
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 577 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08f25138
Analysis symbol:
Rechecking for solution: 0
Report Id: 35e8619a-7631-4b7a-99a4-c3ffa0a7d7c6
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 576 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1034
Faulting application start time: 0x01d7035feda749cb
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 35e8619a-7631-4b7a-99a4-c3ffa0a7d7c6
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 575 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12e250ac
Analysis symbol:
Rechecking for solution: 0
Report Id: b56ef87f-d867-4c24-9719-7e8638c6df10
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 574 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10ec
Faulting application start time: 0x01d7035fed93cd42
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b56ef87f-d867-4c24-9719-7e8638c6df10
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 573 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0832502f
Analysis symbol:
Rechecking for solution: 0
Report Id: 28ef2904-9530-4957-a53c-d5c2550e311b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 572 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x136c
Faulting application start time: 0x01d7035fed80d8e0
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 28ef2904-9530-4957-a53c-d5c2550e311b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 571 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06e64fa2
Analysis symbol:
Rechecking for solution: 0
Report Id: f49c16f7-068e-4fe6-8723-dc2ee13cd001
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 570 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe58
Faulting application start time: 0x01d7035fed6b5c08
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f49c16f7-068e-4fe6-8723-dc2ee13cd001
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 569 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e8a4ef6
Analysis symbol:
Rechecking for solution: 0
Report Id: ea96d455-006c-434f-b0c2-2cca415d420d
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 568 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10f0
Faulting application start time: 0x01d7035fed543c8d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ea96d455-006c-434f-b0c2-2cca415d420d
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 567 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13224e79
Analysis symbol:
Rechecking for solution: 0
Report Id: c99572fd-e846-4706-8aa5-fc59aa87fd1b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 566 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1104
Faulting application start time: 0x01d7035fed406e63
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c99572fd-e846-4706-8aa5-fc59aa87fd1b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 565 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10d24dfc
Analysis symbol:
Rechecking for solution: 0
Report Id: 2a8c4812-5c81-40e7-8e49-ca4d514d02f4
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 564 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x13a4
Faulting application start time: 0x01d7035fed2af3df
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2a8c4812-5c81-40e7-8e49-ca4d514d02f4
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 563 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12764d60
Analysis symbol:
Rechecking for solution: 0
Report Id: 759c315c-fe30-424c-86be-e974e84a1d0b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 562 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xb40
Faulting application start time: 0x01d7035fed1318cc
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 759c315c-fe30-424c-86be-e974e84a1d0b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 561 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bb24cd3
Analysis symbol:
Rechecking for solution: 0
Report Id: e219955e-68fb-40e7-8f22-c9f9801f6260
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 560 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xa38
Faulting application start time: 0x01d7035fecfc7b1a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e219955e-68fb-40e7-8f22-c9f9801f6260
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 559 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06de4c37
Analysis symbol:
Rechecking for solution: 0
Report Id: 1a5c53eb-05b3-4631-9df6-ef795bfe07d5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 558 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x390
Faulting application start time: 0x01d7035fece8498b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1a5c53eb-05b3-4631-9df6-ef795bfe07d5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 557 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_051e4bd9
Analysis symbol:
Rechecking for solution: 0
Report Id: 2297f983-cfdb-4b55-9266-7f4cad55ecd0
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 556 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x29c
Faulting application start time: 0x01d7035fecd5eee9
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2297f983-cfdb-4b55-9266-7f4cad55ecd0
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 555 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a4b6c
Analysis symbol:
Rechecking for solution: 0
Report Id: bd636f89-0957-4792-9302-523690793b63
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 554 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10064b4d
Analysis symbol:
Rechecking for solution: 0
Report Id: d5822231-6cf3-4bff-bee1-24c402ba94b3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 553 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1240
Faulting application start time: 0x01d7035fecc217bc
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d5822231-6cf3-4bff-bee1-24c402ba94b3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 552 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11124ac0
Analysis symbol:
Rechecking for solution: 0
Report Id: 388ca404-9389-4f24-adf6-31a553f38c7e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 551 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xc04
Faulting application start time: 0x01d7035fecac9c57
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 388ca404-9389-4f24-adf6-31a553f38c7e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 550 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a4a62
Analysis symbol:
Rechecking for solution: 0
Report Id: 746c242a-35cf-4e19-abe1-239a156b1a8c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 549 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13424a24
Analysis symbol:
Rechecking for solution: 0
Report Id: 0c1f5650-b0c4-48df-8d42-50e4dbb2b4e3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 548 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12c4
Faulting application start time: 0x01d7035fec94ca9f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0c1f5650-b0c4-48df-8d42-50e4dbb2b4e3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 547 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12f249a7
Analysis symbol:
Rechecking for solution: 0
Report Id: 31123688-5106-4fac-9408-c6b6b55c5101
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 546 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x830
Faulting application start time: 0x01d7035fec81b0fc
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 31123688-5106-4fac-9408-c6b6b55c5101
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 545 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a4949
Analysis symbol:
Rechecking for solution: 0
Report Id: cd340680-9609-41e1-9c19-546a58f1d94b
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 544 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1366492a
Analysis symbol:
Rechecking for solution: 0
Report Id: b810aa1d-89a3-42a6-a7e4-b141d129915f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 543 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x644
Faulting application start time: 0x01d7035fec6de57e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b810aa1d-89a3-42a6-a7e4-b141d129915f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 542 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_120248ad
Analysis symbol:
Rechecking for solution: 0
Report Id: 1ad6315f-97fd-406a-8457-93e6e9654946
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 541 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x230
Faulting application start time: 0x01d7035fec5bad40
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1ad6315f-97fd-406a-8457-93e6e9654946
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 540 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a4840
Analysis symbol:
Rechecking for solution: 0
Report Id: 5e995150-00c1-4c64-803a-2acbc40e0e0b
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 539 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f0e4830
Analysis symbol:
Rechecking for solution: 0
Report Id: 6a725c53-ed07-4e20-9484-cd6af3cd36c5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 538 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe7c
Faulting application start time: 0x01d7035fec4891d4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 6a725c53-ed07-4e20-9484-cd6af3cd36c5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 537 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12d247a3
Analysis symbol:
Rechecking for solution: 0
Report Id: efc33488-bcbc-4fe8-9241-9d2b664c8709
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 536 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x494
Faulting application start time: 0x01d7035fec3580da
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: efc33488-bcbc-4fe8-9241-9d2b664c8709
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 535 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12464736
Analysis symbol:
Rechecking for solution: 0
Report Id: bae1ca61-eea1-4cdf-af38-a938e2597aaa
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 534 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x560
Faulting application start time: 0x01d7035fec226207
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: bae1ca61-eea1-4cdf-af38-a938e2597aaa
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 533 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_103646a9
Analysis symbol:
Rechecking for solution: 0
Report Id: 9cdface4-5edd-481a-92d1-9f238d9ec30c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 532 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x83c
Faulting application start time: 0x01d7035fec0cec35
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9cdface4-5edd-481a-92d1-9f238d9ec30c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 531 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c72460d
Analysis symbol:
Rechecking for solution: 0
Report Id: 3952c965-f9dc-4b6a-9c15-12afa3b7a499
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 530 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a45cf
Analysis symbol:
Rechecking for solution: 0
Report Id: 0b32bf73-1311-4cb9-9e62-937e53ad681e
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 529 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11b0
Faulting application start time: 0x01d7035febf59496
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 3952c965-f9dc-4b6a-9c15-12afa3b7a499
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 528 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12224590
Analysis symbol:
Rechecking for solution: 0
Report Id: 4f952c05-c96b-4d30-869d-563362e6f39b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 527 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1314
Faulting application start time: 0x01d7035febe202b7
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4f952c05-c96b-4d30-869d-563362e6f39b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 526 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_058a4503
Analysis symbol:
Rechecking for solution: 0
Report Id: b344b5cb-8f3e-43b2-bfeb-aeccc9c9c252
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 525 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a44c5
Analysis symbol:
Rechecking for solution: 0
Report Id: 2fff2ec0-c889-40b4-a7e7-888db6afec3f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 524 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x398
Faulting application start time: 0x01d7035febccb4e1
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b344b5cb-8f3e-43b2-bfeb-aeccc9c9c252
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 523 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06b24477
Analysis symbol:
Rechecking for solution: 0
Report Id: 4ccd0adb-7da0-4ee2-862c-cda3934a6a09
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 522 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x23c
Faulting application start time: 0x01d7035febb76b1f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4ccd0adb-7da0-4ee2-862c-cda3934a6a09
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 521 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_090a43fa
Analysis symbol:
Rechecking for solution: 0
Report Id: 718f0aa2-6bb2-41e6-934d-c5791ce7c4c7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 520 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a43ac
Analysis symbol:
Rechecking for solution: 0
Report Id: 33a24b47-dec3-4be8-b6aa-9c3fd39e0e21
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 519 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1158
Faulting application start time: 0x01d7035feba4002e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 718f0aa2-6bb2-41e6-934d-c5791ce7c4c7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 518 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10be436d
Analysis symbol:
Rechecking for solution: 0
Report Id: 78061afe-51df-4c8f-b025-6bd90a6a170c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 517 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x74c
Faulting application start time: 0x01d7035feb8ebfa1
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 78061afe-51df-4c8f-b025-6bd90a6a170c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 516 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a3642e1
Analysis symbol:
Rechecking for solution: 0
Report Id: 4e2201f1-9ccc-408f-ae6a-076c3fff2e68
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 515 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a42a2
Analysis symbol:
Rechecking for solution: 0
Report Id: e5b1595c-3447-4612-90f4-7638a48a1843
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 514 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x135c
Faulting application start time: 0x01d7035feb791dda
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4e2201f1-9ccc-408f-ae6a-076c3fff2e68
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 513 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_111a4264
Analysis symbol:
Rechecking for solution: 0
Report Id: 51a17ae7-2cb1-43ec-85a9-2d1605676858
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 512 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x390
Faulting application start time: 0x01d7035feb667a9e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 51a17ae7-2cb1-43ec-85a9-2d1605676858
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 511 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_029241e7
Analysis symbol:
Rechecking for solution: 0
Report Id: 12f599bc-d688-4e03-9046-f40a6a7e6d27
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 510 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12e8
Faulting application start time: 0x01d7035feb52f791
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 12f599bc-d688-4e03-9046-f40a6a7e6d27
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 509 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a4189
Analysis symbol:
Rechecking for solution: 0
Report Id: a832c409-bd38-4c7d-ae53-045a23c6761c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 508 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11ca416a
Analysis symbol:
Rechecking for solution: 0
Report Id: 337a3594-b317-441d-bc98-f6c2a2a5644e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 507 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1048
Faulting application start time: 0x01d7035feb400850
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 337a3594-b317-441d-bc98-f6c2a2a5644e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 506 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c0a40ed
Analysis symbol:
Rechecking for solution: 0
Report Id: 417df2ec-ad25-4d54-8d78-586bbe975f97
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 505 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x4e8
Faulting application start time: 0x01d7035feb2ccf55
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 417df2ec-ad25-4d54-8d78-586bbe975f97
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 504 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_123a4070
Analysis symbol:
Rechecking for solution: 0
Report Id: 063ce8c5-92f4-4fd0-b649-3ba8cc481801
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 503 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xf6c
Faulting application start time: 0x01d7035feb173c17
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 063ce8c5-92f4-4fd0-b649-3ba8cc481801
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 502 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139a3ff3
Analysis symbol:
Rechecking for solution: 0
Report Id: 1e9efb77-e5b4-4bca-9e5b-7784aeda4701
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 501 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12963fe3
Analysis symbol:
Rechecking for solution: 0
Report Id: 08540c9f-85f0-4479-87c0-0bd9ce6aa41f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 500 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xdc
Faulting application start time: 0x01d7035feb043086
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 08540c9f-85f0-4479-87c0-0bd9ce6aa41f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 499 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_083e3f66
Analysis symbol:
Rechecking for solution: 0
Report Id: 7388977a-04fc-45ab-b071-eccc8a79255f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 498 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12d0
Faulting application start time: 0x01d7035feaf1fe6a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7388977a-04fc-45ab-b071-eccc8a79255f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 497 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06623ef9
Analysis symbol:
Rechecking for solution: 0
Report Id: 25a01f27-48d3-42e0-b39d-83db62c4d4b3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 496 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1068
Faulting application start time: 0x01d7035feadfcec4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 25a01f27-48d3-42e0-b39d-83db62c4d4b3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 495 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e923e7c
Analysis symbol:
Rechecking for solution: 0
Report Id: 3fa3f7b1-3d0d-4208-8baa-64c470150fa4
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 494 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xf14
Faulting application start time: 0x01d7035feacd4478
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 3fa3f7b1-3d0d-4208-8baa-64c470150fa4
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 493 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_064a3dff
Analysis symbol:
Rechecking for solution: 0
Report Id: 451519c8-36dd-4c55-a216-33470d5cbd23
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 492 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x8a8
Faulting application start time: 0x01d7035feaba7692
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 451519c8-36dd-4c55-a216-33470d5cbd23
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 491 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11863d72
Analysis symbol:
Rechecking for solution: 0
Report Id: 2e70407b-313d-4389-bb6a-6204cc700e13
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 490 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1050
Faulting application start time: 0x01d7035feaa57439
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2e70407b-313d-4389-bb6a-6204cc700e13
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 489 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_01663ce5
Analysis symbol:
Rechecking for solution: 0
Report Id: d41081fe-5a84-4a65-813c-c03b360be8a5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 488 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11ec
Faulting application start time: 0x01d7035fea8ecc94
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d41081fe-5a84-4a65-813c-c03b360be8a5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 487 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10023c68
Analysis symbol:
Rechecking for solution: 0
Report Id: 48be9eda-d3a8-4cff-95da-fde60eb561d0
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 486 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xedc
Faulting application start time: 0x01d7035fea7c68ea
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 48be9eda-d3a8-4cff-95da-fde60eb561d0
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 485 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10b23bdc
Analysis symbol:
Rechecking for solution: 0
Report Id: 78d4ae45-24e8-4f02-b85b-9ecf819ba384
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 484 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11b8
Faulting application start time: 0x01d7035fea6702c9
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 78d4ae45-24e8-4f02-b85b-9ecf819ba384
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 483 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ba63b20
Analysis symbol:
Rechecking for solution: 0
Report Id: b251175a-3568-4995-8031-4fb2a5b4e315
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 482 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f663b5f
Analysis symbol:
Rechecking for solution: 0
Report Id: c54d6cd1-a852-4a68-94ed-f8b391d449e3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 481 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe84
Faulting application start time: 0x01d7035fea550f21
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c54d6cd1-a852-4a68-94ed-f8b391d449e3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 480 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08e23af1
Analysis symbol:
Rechecking for solution: 0
Report Id: a4472bdb-be81-4d3b-8e7f-63b95435336f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 479 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe08
Faulting application start time: 0x01d7035fea432c41
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a4472bdb-be81-4d3b-8e7f-63b95435336f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 478 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12923a65
Analysis symbol:
Rechecking for solution: 0
Report Id: 0d862c66-87e2-4777-9f36-74e54701247b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 477 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10b8
Faulting application start time: 0x01d7035fea2d1dbb
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0d862c66-87e2-4777-9f36-74e54701247b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 476 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b9239e8
Analysis symbol:
Rechecking for solution: 0
Report Id: 1b00cc10-bc83-43db-947d-7ea1e8060e5c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 475 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x858
Faulting application start time: 0x01d7035fea1af958
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1b00cc10-bc83-43db-947d-7ea1e8060e5c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 474 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1236397a
Analysis symbol:
Rechecking for solution: 0
Report Id: 8e889c01-4073-4a1d-a9ec-82506d59f812
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 473 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe40
Faulting application start time: 0x01d7035fea0888ef
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 8e889c01-4073-4a1d-a9ec-82506d59f812
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 472 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13be38ee
Analysis symbol:
Rechecking for solution: 0
Report Id: bd636f89-0957-4792-9302-523690793b63
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 471 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xee4
Faulting application start time: 0x01d7035fe9f35ea5
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: bd636f89-0957-4792-9302-523690793b63
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 470 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_087a3871
Analysis symbol:
Rechecking for solution: 0
Report Id: 746c242a-35cf-4e19-abe1-239a156b1a8c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 469 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10b4
Faulting application start time: 0x01d7035fe9e161d2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 746c242a-35cf-4e19-abe1-239a156b1a8c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 468 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13f237d4
Analysis symbol:
Rechecking for solution: 0
Report Id: cd340680-9609-41e1-9c19-546a58f1d94b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 467 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe88
Faulting application start time: 0x01d7035fe9cbe47a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: cd340680-9609-41e1-9c19-546a58f1d94b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 466 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_065e3767
Analysis symbol:
Rechecking for solution: 0
Report Id: 5e995150-00c1-4c64-803a-2acbc40e0e0b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 465 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x29c
Faulting application start time: 0x01d7035fe9b7e7ff
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5e995150-00c1-4c64-803a-2acbc40e0e0b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 464 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?15T06:00:45.150449400Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 463 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 736 | 2140 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 6:00:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ce36da
Analysis symbol:
Rechecking for solution: 0
Report Id: 0b32bf73-1311-4cb9-9e62-937e53ad681e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 462 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11c4
Faulting application start time: 0x01d7035fe9a36dbd
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0b32bf73-1311-4cb9-9e62-937e53ad681e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 461 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1342363e
Analysis symbol:
Rechecking for solution: 0
Report Id: 2fff2ec0-c889-40b4-a7e7-888db6afec3f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 460 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xc04
Faulting application start time: 0x01d7035fe98e265a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2fff2ec0-c889-40b4-a7e7-888db6afec3f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 459 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_09da35e0
Analysis symbol:
Rechecking for solution: 0
Report Id: 33a24b47-dec3-4be8-b6aa-9c3fd39e0e21
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 458 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x20
Faulting application start time: 0x01d7035fe97d38be
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 33a24b47-dec3-4be8-b6aa-9c3fd39e0e21
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 457 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02123554
Analysis symbol:
Rechecking for solution: 0
Report Id: e5b1595c-3447-4612-90f4-7638a48a1843
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 456 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe14
Faulting application start time: 0x01d7035fe967e2f2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e5b1595c-3447-4612-90f4-7638a48a1843
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 455 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_056634d7
Analysis symbol:
Rechecking for solution: 0
Report Id: a832c409-bd38-4c7d-ae53-045a23c6761c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 454 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12e4
Faulting application start time: 0x01d7035fe954b847
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a832c409-bd38-4c7d-ae53-045a23c6761c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 453 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_122e344a
Analysis symbol:
Rechecking for solution: 0
Report Id: 1e9efb77-e5b4-4bca-9e5b-7784aeda4701
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 452 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10e0
Faulting application start time: 0x01d7035fe940250f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1e9efb77-e5b4-4bca-9e5b-7784aeda4701
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 451 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06a633cd
Analysis symbol:
Rechecking for solution: 0
Report Id: b251175a-3568-4995-8031-4fb2a5b4e315
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 450 | Windows Error Reporting | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 1892. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 449 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 6:00:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 448 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 6:00:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 447 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 6:00:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10d4
Faulting application start time: 0x01d7035fe8f8d9fe
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b251175a-3568-4995-8031-4fb2a5b4e315
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 446 | Application Error | | Application | | | hv-osbrick-7755 | | 2/15/2021 6:00:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?15T06:00:45.150449400Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 445 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 736 | 692 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 6:00:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root list with effective date: ?Friday, ?January ?15, ?2021 12:42:37 AM. | 4111 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 444 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 443 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 442 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 441 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 440 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 439 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 438 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 437 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 436 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1816 | hv-osbrick-7755 | | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 1892. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 435 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 6:00:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 434 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1812 | hv-osbrick-7755 | | 2/15/2021 6:00:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 433 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 2976 | 4256 | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:51:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?15T05:51:20.576602400Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 432 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2380 | 1172 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4308. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 431 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 430 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 429 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?15T05:51:20.576602400Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 428 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2380 | 692 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?15T05:51:20.061326600Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 427 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2380 | 1172 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?15T05:51:20.061326600Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 426 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2380 | 5028 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4308. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 425 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4308. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 424 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 423 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 422 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4308. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 421 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:51:19 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0. | 1035 | | 0 | 4 | 0 | | 36028797018963968 | 420 | MsiInstaller | | Application | | | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:51:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?15T05:50:37.656412500Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 419 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 1704 | 5024 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:50:37 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?15T05:50:37.640725900Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 418 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 1704 | 5024 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1001 | 2/15/2021 5:50:37 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 417 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1372 | hv-osbrick-7755 | | 2/15/2021 5:49:59 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 416 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-16T05:48:54Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 415 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 414 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:24 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/08/14:05:49:23;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 413 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 412 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259200 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 411 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 410 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 409 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
These policies are being excluded since they are only defined with override-only attribute.
Policy Names=(Security-SPP-Reserved-EnableNotificationMode)
App Id=55c92734-d682-4d71-983e-d6ec3f16059f
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1033 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 408 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 407 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Validity period has been started. Validity minutes=259200 Grace type=9. | 1036 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 406 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MSA client has been successfully triggered to update the Device License | 12311 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 405 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:22 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f} | 12304 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 404 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:22 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f | 12305 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 403 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:22 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection ended.
| 20489 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 402 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 401 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check passed.
| 20482 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 400 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check initiated.
| 20481 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 399 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:19 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection started.
| 20488 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 398 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:19 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS.
| 1067 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 397 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE}
License Id=b784e57e-d2b6-4e6f-a164-90db5192cf89 | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 396 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC}
License Id=0752b08c-caba-4da4-82f6-305316778afa | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 395 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Acquisition of End User License was successful.
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1013 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 394 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 393 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1808 | hv-osbrick-7755 | | 2/15/2021 5:49:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/02/25:05:44:08;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 392 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:49:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
MSDTC started with the following settings:
Security Configuration (OFF = 0 and ON = 1):
Allow Remote Administrator = 0,
Network Clients = 0,
Transaction Manager Communication:
Allow Inbound Transactions = 0,
Allow Outbound Transactions = 0,
Transaction Internet Protocol (TIP) = 0,
Enable XA Transactions = 0,
Enable SNA LU 6.2 Transactions = 1,
MSDTC Communications Security = Mutual Authentication Required,
Account = NT AUTHORITY\NetworkService,
Firewall Exclusion Detected = 0
Transaction Bridge Installed = 0
Filtering Duplicate Events = 1
| 4202 | 0 | 16384 | 4 | 2 | 0 | 36028797018963968 | 391 | Microsoft-Windows-MSDTC 2 | 5d9e0020-3761-4f36-90c8-38ce6511bd12 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:47:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | TM | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 390 | cloudbase-init | | Application | | | hv-osbrick-7755 | | 2/15/2021 5:46:31 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 389 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:46:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 388 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 584 | 2872 | hv-osbrick-7755 | S-1-5-21-2528364749-2435346785-3759239727-1000 | 2/15/2021 5:46:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7755\Admin' in response to user profile creation. Error code 0x80070005.
Access is denied.
. | 6 | 0 | 49152 | 2 | 0 | 0 | 36028797018963968 | 387 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:46:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 386 | cloudbase-init | | Application | | | hv-osbrick-7755 | | 2/15/2021 5:45:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7755\cloudbase-init' .
| 5 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 385 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:45:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 384 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1336 | 1368 | hv-osbrick-7755 | | 2/15/2021 5:45:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 383 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 584 | 2032 | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:45:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 382 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 584 | 1292 | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:45:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Delete for component {D63AA156-D534-4BAC-9BF1-55359CF5EC30} failed, error code is The system cannot find the path specified.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 381 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 584 | 792 | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:45:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 380 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 584 | 1700 | hv-osbrick-7755 | S-1-5-18 | 2/15/2021 5:45:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 379 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:45:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 378 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:45:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Proof of Purchase installed successfully.
ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4
PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845 | 1016 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 377 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:45:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 376 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | hv-osbrick-7755 | | 2/15/2021 5:45:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 375 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 528 | 1516 | WIN-5T344G8GM1H | S-1-5-18 | 2/15/2021 5:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 374 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 2/15/2021 5:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de}
Writer Name: Microsoft Hyper-V VSS Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 373 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/15/2021 5:44:27 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM. | 4112 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 372 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1720 | 1848 | WIN-5T344G8GM1H | | 2/15/2021 5:44:22 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 371 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 528 | 580 | WIN-5T344G8GM1H | S-1-5-18 | 2/15/2021 5:44:17 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 370 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 528 | 1584 | WIN-5T344G8GM1H | S-1-5-18 | 2/15/2021 5:44:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 369 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 528 | 1516 | WIN-5T344G8GM1H | S-1-5-18 | 2/15/2021 5:44:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f}
Writer Name: Shadow Copy Optimization Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 368 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/15/2021 5:44:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4}
Writer Name: ASR Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 367 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/15/2021 5:44:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f}
Writer Name: COM+ REGDB Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 366 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/15/2021 5:44:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485}
Writer Name: Registry Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 365 | VSS | | Application | | | WIN-NF4A8KG2C0P | | 2/15/2021 5:44:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 364 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 1228 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required.
DETAIL -
9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500:
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore
Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main
Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security
| 1530 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 363 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 3432 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The winlogon notification subscriber <SessionEnv> failed a notification event. | 6001 | 0 | 32768 | 3 | 0 | 0 | 36028797018963968 | 362 | Microsoft-Windows-Winlogon | dbe9b383-7cf3-4331-91cc-a3cb16a3b538 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 361 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448 | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 360 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 359 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining. | 12306 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 358 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 357 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 356 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Grace period has been started. Grace days=10 Grace type=6. | 1025 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 355 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 354 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The hardware has changed. | 1024 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 353 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Hardware has changed from previous boot.
AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4. | 1040 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 352 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 351 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=Sysprep.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 350 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MS DTC service is stopping. | 4111 | 0 | 16384 | 4 | 1 | 0 | 36028797018963968 | 349 | Microsoft-Windows-MSDTC | 719be4ed-e9bc-4dd8-a7cf-c85ce8e4975d | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:47:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | SVC | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |