Message | Id | Version | Qualifiers | Level | Task | Opcode | Keywords | RecordId | ProviderName | ProviderId | LogName | ProcessId | ThreadId | MachineName | UserId | TimeCreated | ActivityId | RelatedActivityId | ContainerLog | MatchedQueryIds | Bookmark | LevelDisplayName | OpcodeDisplayName | TaskDisplayName | KeywordsDisplayNames | Properties |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 551 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:54:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-03T09:53:11Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 550 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:54:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 549 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:53:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259174 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 548 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:53:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 547 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:53:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 546 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:53:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 545 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:53:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc248e
Analysis symbol:
Rechecking for solution: 0
Report Id: 89eed9e5-4673-419d-8a56-a34073adcef8
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 544 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2365
Analysis symbol:
Rechecking for solution: 0
Report Id: 2bc4b9ef-155f-417f-a94f-0306c1fa8b32
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 543 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc225b
Analysis symbol:
Rechecking for solution: 0
Report Id: 66501514-db12-472d-960a-7fd9401f0cac
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 542 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2152
Analysis symbol:
Rechecking for solution: 0
Report Id: 2abb12d3-2829-4dba-b808-da8c780bd0ba
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 541 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2038
Analysis symbol:
Rechecking for solution: 0
Report Id: 7719b409-cf39-4d5f-bdd5-f3a16df838fb
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 540 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:14 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1f00
Analysis symbol:
Rechecking for solution: 0
Report Id: f70d0603-8032-4efe-8fc4-0c0dacbb8ab6
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 539 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:14 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1c50
Analysis symbol:
Rechecking for solution: 0
Report Id: 7ea6062a-a3ac-444a-b524-651270c4a3b8
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 538 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139c1b76
Analysis symbol:
Rechecking for solution: 0
Report Id: ecb41c4f-3b67-447c-b64c-902fe2b0622d
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 537 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1aca
Analysis symbol:
Rechecking for solution: 0
Report Id: 2ff492b9-f50b-4eae-9ba2-5e48d9545ef4
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 536 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x508
Faulting application start time: 0x01d6f9481aa33faf
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ecb41c4f-3b67-447c-b64c-902fe2b0622d
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 535 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5c1a6c
Analysis symbol:
Rechecking for solution: 0
Report Id: 5db9a3ba-1307-4770-acd0-fb793fbffc05
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 534 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x568
Faulting application start time: 0x01d6f9481a78ab45
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5db9a3ba-1307-4770-acd0-fb793fbffc05
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 533 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1982
Analysis symbol:
Rechecking for solution: 0
Report Id: 1fda18ee-a218-4ff9-bcc0-2b294991015d
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 532 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11701943
Analysis symbol:
Rechecking for solution: 0
Report Id: cb6910f1-f19f-46c6-9d9f-81a7671a34cb
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 531 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x77c
Faulting application start time: 0x01d6f9481a49e95c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: cb6910f1-f19f-46c6-9d9f-81a7671a34cb
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 530 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d34182a
Analysis symbol:
Rechecking for solution: 0
Report Id: 56663ae0-f093-4f2a-8056-80c63c743038
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 529 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc17bc
Analysis symbol:
Rechecking for solution: 0
Report Id: 1d1f4601-9957-4393-be4f-f921f05a111a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 528 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10d4
Faulting application start time: 0x01d6f9481a21d776
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 56663ae0-f093-4f2a-8056-80c63c743038
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 527 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04641730
Analysis symbol:
Rechecking for solution: 0
Report Id: 791f1e26-1eea-4729-8fd1-7499fc778922
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 526 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x9e8
Faulting application start time: 0x01d6f94819fccb4c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 791f1e26-1eea-4729-8fd1-7499fc778922
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 525 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc15c8
Analysis symbol:
Rechecking for solution: 0
Report Id: 67224c84-4e89-44ff-9e65-90e0521687f7
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 524 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08cc1636
Analysis symbol:
Rechecking for solution: 0
Report Id: 11ce1451-b5e0-42eb-a8a2-11844fce700c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 523 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1218
Faulting application start time: 0x01d6f94819d96a3a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 11ce1451-b5e0-42eb-a8a2-11844fce700c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 522 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1000154b
Analysis symbol:
Rechecking for solution: 0
Report Id: 3211f747-2ebe-4870-be0d-845ce4da1573
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 521 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xae0
Faulting application start time: 0x01d6f94819b40590
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 3211f747-2ebe-4870-be0d-845ce4da1573
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 520 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1461
Analysis symbol:
Rechecking for solution: 0
Report Id: f0fd91b0-a280-4488-9122-1bca739cb2cf
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 519 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_121c1432
Analysis symbol:
Rechecking for solution: 0
Report Id: 5654933d-9137-4a14-8a5a-b239334706d8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 518 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x100c
Faulting application start time: 0x01d6f948198805aa
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5654933d-9137-4a14-8a5a-b239334706d8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 517 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11d81329
Analysis symbol:
Rechecking for solution: 0
Report Id: e91656b0-0780-42a8-98f3-2f20d1b2d9d0
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 516 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xca4
Faulting application start time: 0x01d6f948195cb3d1
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e91656b0-0780-42a8-98f3-2f20d1b2d9d0
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 515 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0cfc121f
Analysis symbol:
Rechecking for solution: 0
Report Id: 6729fc6c-9af8-4b2c-ac72-b0b4099a5285
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 514 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1010
Faulting application start time: 0x01d6f9481936dae2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 6729fc6c-9af8-4b2c-ac72-b0b4099a5285
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 513 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:11 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11641106
Analysis symbol:
Rechecking for solution: 0
Report Id: 89eed9e5-4673-419d-8a56-a34073adcef8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 512 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe40
Faulting application start time: 0x01d6f948190a7417
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 89eed9e5-4673-419d-8a56-a34073adcef8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 511 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c103b
Analysis symbol:
Rechecking for solution: 0
Report Id: c16ef8dc-fe06-47c0-8a03-9dcf6a257ed7
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 510 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13800fdd
Analysis symbol:
Rechecking for solution: 0
Report Id: 2bc4b9ef-155f-417f-a94f-0306c1fa8b32
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 509 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1f8
Faulting application start time: 0x01d6f94818e030f4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2bc4b9ef-155f-417f-a94f-0306c1fa8b32
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 508 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c0e95
Analysis symbol:
Rechecking for solution: 0
Report Id: 2922782c-48db-4283-8be4-9b6a88c5feb1
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 507 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0dc00ed3
Analysis symbol:
Rechecking for solution: 0
Report Id: 66501514-db12-472d-960a-7fd9401f0cac
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 506 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1248
Faulting application start time: 0x01d6f94818b6835b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 66501514-db12-472d-960a-7fd9401f0cac
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 505 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_01600de9
Analysis symbol:
Rechecking for solution: 0
Report Id: 2abb12d3-2829-4dba-b808-da8c780bd0ba
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 504 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c0d0e
Analysis symbol:
Rechecking for solution: 0
Report Id: 2f6284ed-b430-49cd-8109-61489e7029e1
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 503 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1320
Faulting application start time: 0x01d6f94818954af4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2abb12d3-2829-4dba-b808-da8c780bd0ba
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 502 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d200cef
Analysis symbol:
Rechecking for solution: 0
Report Id: 7719b409-cf39-4d5f-bdd5-f3a16df838fb
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 501 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11c4
Faulting application start time: 0x01d6f948186d0c73
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7719b409-cf39-4d5f-bdd5-f3a16df838fb
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 500 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05b80c14
Analysis symbol:
Rechecking for solution: 0
Report Id: f70d0603-8032-4efe-8fc4-0c0dacbb8ab6
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 499 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c0bb6
Analysis symbol:
Rechecking for solution: 0
Report Id: 65c645a3-9f8a-44b8-8a40-593aa54e6152
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 498 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x8c4
Faulting application start time: 0x01d6f9481845beab
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f70d0603-8032-4efe-8fc4-0c0dacbb8ab6
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 497 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12400b0a
Analysis symbol:
Rechecking for solution: 0
Report Id: 7ea6062a-a3ac-444a-b524-651270c4a3b8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 496 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c0a9d
Analysis symbol:
Rechecking for solution: 0
Report Id: f5ad2a4c-0592-44c4-90ab-7914156c4aba
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 495 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe34
Faulting application start time: 0x01d6f948181dbbb2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7ea6062a-a3ac-444a-b524-651270c4a3b8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 494 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_080c0a01
Analysis symbol:
Rechecking for solution: 0
Report Id: 2ff492b9-f50b-4eae-9ba2-5e48d9545ef4
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 493 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c0955
Analysis symbol:
Rechecking for solution: 0
Report Id: fd1cfc6a-3be6-49c3-8e25-f35c6b931c2a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 492 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12d4
Faulting application start time: 0x01d6f94817f990b3
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2ff492b9-f50b-4eae-9ba2-5e48d9545ef4
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 491 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ea008f7
Analysis symbol:
Rechecking for solution: 0
Report Id: 1fda18ee-a218-4ff9-bcc0-2b294991015d
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 490 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12a0
Faulting application start time: 0x01d6f94817d1655d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1fda18ee-a218-4ff9-bcc0-2b294991015d
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 489 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c083c
Analysis symbol:
Rechecking for solution: 0
Report Id: 9652d979-57d9-4ee1-b82a-be85b11e2ca5
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 488 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a0807fd
Analysis symbol:
Rechecking for solution: 0
Report Id: 1d1f4601-9957-4393-be4f-f921f05a111a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 487 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x568
Faulting application start time: 0x01d6f94817aa9254
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1d1f4601-9957-4393-be4f-f921f05a111a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 486 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f7c06f4
Analysis symbol:
Rechecking for solution: 0
Report Id: 67224c84-4e89-44ff-9e65-90e0521687f7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 485 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1378
Faulting application start time: 0x01d6f9481782d4d7
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 67224c84-4e89-44ff-9e65-90e0521687f7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 484 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0fd005ea
Analysis symbol:
Rechecking for solution: 0
Report Id: f0fd91b0-a280-4488-9122-1bca739cb2cf
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 483 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:08 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11ec
Faulting application start time: 0x01d6f9481759c6fd
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f0fd91b0-a280-4488-9122-1bca739cb2cf
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 482 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11e00500
Analysis symbol:
Rechecking for solution: 0
Report Id: c16ef8dc-fe06-47c0-8a03-9dcf6a257ed7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 481 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03d80425
Analysis symbol:
Rechecking for solution: 0
Report Id: a6e1a3e3-967f-4468-8ecc-c26b4de6d748
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 480 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x470
Faulting application start time: 0x01d6f94817338a06
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c16ef8dc-fe06-47c0-8a03-9dcf6a257ed7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 479 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_116003f6
Analysis symbol:
Rechecking for solution: 0
Report Id: 2922782c-48db-4283-8be4-9b6a88c5feb1
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 478 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x115c
Faulting application start time: 0x01d6f948170fccd9
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2922782c-48db-4283-8be4-9b6a88c5feb1
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 477 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03d8033a
Analysis symbol:
Rechecking for solution: 0
Report Id: acb93df9-63e7-44cd-ad51-ca87128bb573
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 476 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1338030c
Analysis symbol:
Rechecking for solution: 0
Report Id: 2f6284ed-b430-49cd-8109-61489e7029e1
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 475 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1218
Faulting application start time: 0x01d6f94816ec081a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2f6284ed-b430-49cd-8109-61489e7029e1
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 474 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03d80212
Analysis symbol:
Rechecking for solution: 0
Report Id: f874cbf3-5467-4ff0-9606-c898fe442b79
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 473 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c780212
Analysis symbol:
Rechecking for solution: 0
Report Id: 65c645a3-9f8a-44b8-8a40-593aa54e6152
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 472 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x914
Faulting application start time: 0x01d6f94816c35f22
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 65c645a3-9f8a-44b8-8a40-593aa54e6152
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 471 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03d800f8
Analysis symbol:
Rechecking for solution: 0
Report Id: 00281941-4699-4147-99d4-1fa3bb30c7bb
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 470 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e700137
Analysis symbol:
Rechecking for solution: 0
Report Id: f5ad2a4c-0592-44c4-90ab-7914156c4aba
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 469 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x88c
Faulting application start time: 0x01d6f948169c46ae
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f5ad2a4c-0592-44c4-90ab-7914156c4aba
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 468 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b40001e
Analysis symbol:
Rechecking for solution: 0
Report Id: fd1cfc6a-3be6-49c3-8e25-f35c6b931c2a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 467 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11cc
Faulting application start time: 0x01d6f948167416b6
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: fd1cfc6a-3be6-49c3-8e25-f35c6b931c2a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 466 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0863ff04
Analysis symbol:
Rechecking for solution: 0
Report Id: 9652d979-57d9-4ee1-b82a-be85b11e2ca5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 465 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x6b4
Faulting application start time: 0x01d6f948164c721a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9652d979-57d9-4ee1-b82a-be85b11e2ca5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 464 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12abfdeb
Analysis symbol:
Rechecking for solution: 0
Report Id: a6e1a3e3-967f-4468-8ecc-c26b4de6d748
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 463 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11b8
Faulting application start time: 0x01d6f948161eb128
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a6e1a3e3-967f-4468-8ecc-c26b4de6d748
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 462 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05a3fcd2
Analysis symbol:
Rechecking for solution: 0
Report Id: 84934453-7792-4a17-b03b-69cd5801ab1a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 461 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0dd3fce1
Analysis symbol:
Rechecking for solution: 0
Report Id: acb93df9-63e7-44cd-ad51-ca87128bb573
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 460 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x50c
Faulting application start time: 0x01d6f94815f7dd11
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: acb93df9-63e7-44cd-ad51-ca87128bb573
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 459 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?02T09:44:57.335896100Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 458 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 5036 | 4316 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:45:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b3fbc8
Analysis symbol:
Rechecking for solution: 0
Report Id: f874cbf3-5467-4ff0-9606-c898fe442b79
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 457 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x770
Faulting application start time: 0x01d6f94815cb8770
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f874cbf3-5467-4ff0-9606-c898fe442b79
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 456 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b5ffaaf
Analysis symbol:
Rechecking for solution: 0
Report Id: 00281941-4699-4147-99d4-1fa3bb30c7bb
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 455 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xbe8
Faulting application start time: 0x01d6f94815a20bd4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 00281941-4699-4147-99d4-1fa3bb30c7bb
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 454 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d53f948
Analysis symbol:
Rechecking for solution: 0
Report Id: 84934453-7792-4a17-b03b-69cd5801ab1a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 453 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4204. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 452 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:45:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 451 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:45:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 450 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:45:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe38
Faulting application start time: 0x01d6f948152e5a43
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 84934453-7792-4a17-b03b-69cd5801ab1a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 449 | Application Error | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:45:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?02T09:44:57.335896100Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 448 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 5036 | 4252 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root list with effective date: ?Friday, ?January ?15, ?2021 12:42:37 AM. | 4111 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 447 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 446 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 445 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 444 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 443 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 442 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 441 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 440 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 439 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4012 | hv-osbrick-7736 | | 2/2/2021 9:44:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4204. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 438 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:44:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 437 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 1372 | hv-osbrick-7736 | | 2/2/2021 9:44:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?02T09:30:39.519809800Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 436 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4920 | 4860 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 1496. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 435 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:30:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 434 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 433 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?02T09:30:39.519809800Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 432 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4920 | 3180 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?02T09:30:38.798445800Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 431 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4920 | 4860 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 1496. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 430 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 1496. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 429 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:30:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 428 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 427 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?02T09:30:38.798445800Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 426 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4920 | 4588 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 425 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 4552 | 4416 | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:30:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 1496. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 424 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:30:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0. | 1035 | | 0 | 4 | 0 | | 36028797018963968 | 423 | MsiInstaller | | Application | | | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:30:29 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?02T09:29:44.463424800Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 422 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3900 | 2900 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:29:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?02T09:29:44.443668500Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 421 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3900 | 2900 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1001 | 2/2/2021 9:29:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 420 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 2032 | hv-osbrick-7736 | | 2/2/2021 9:28:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 419 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:27:25 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-03T09:26:25Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 418 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:27:25 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 417 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/08/01:09:26:53;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 416 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:55 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 415 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259200 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 414 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 413 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 412 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:53 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
These policies are being excluded since they are only defined with override-only attribute.
Policy Names=(Security-SPP-Reserved-EnableNotificationMode)
App Id=55c92734-d682-4d71-983e-d6ec3f16059f
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1033 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 411 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 410 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Validity period has been started. Validity minutes=259200 Grace type=9. | 1036 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 409 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MSA client has been successfully triggered to update the Device License | 12311 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 408 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f} | 12304 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 407 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f | 12305 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 406 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection ended.
| 20489 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 405 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 404 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check passed.
| 20482 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 403 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check initiated.
| 20481 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 402 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection started.
| 20488 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 401 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS.
| 1067 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 400 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE}
License Id=20b838df-def3-47e6-b74e-f8eaea28354a | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 399 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC}
License Id=d5050964-f3c4-4565-b1a1-02c89bb15d07 | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 398 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Acquisition of End User License was successful.
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1013 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 397 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 396 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 2948 | hv-osbrick-7736 | | 2/2/2021 9:26:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/02/12:09:21:34;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 395 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:26:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: PnPDeviceProblemCode
Response: Not available
Cab Id: 0
Problem signature:
P1: x64
P2: vms_vsmp
P3: {4d36e972-e325-11ce-bfc1-08002be10318}
P4: 0000000A
P5: vmswitch.sys
P6: 10.0.14393.2007
P7: 01-19-2018
P8:
P9:
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\NonCritical_x64_7ec78536c71350a62c57cbdeaeaef385ea94692b_00000000_0a0a910b
Analysis symbol:
Rechecking for solution: 0
Report Id: a9ae1dc8-6538-11eb-8785-fa163e5ef461
Report Status: 8192
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 394 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:26:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: PnPDeviceProblemCode
Response: Not available
Cab Id: 0
Problem signature:
P1: x64
P2: vms_vsmp
P3: {4d36e972-e325-11ce-bfc1-08002be10318}
P4: 0000000A
P5: vmswitch.sys
P6: 10.0.14393.2007
P7: 01-19-2018
P8:
P9:
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\NonCritical_x64_7ec78536c71350a62c57cbdeaeaef385ea94692b_00000000_08da8727
Analysis symbol:
Rechecking for solution: 0
Report Id: a9ae1dc8-6538-11eb-8785-fa163e5ef461
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 393 | Windows Error Reporting | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:26:01 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
MSDTC started with the following settings:
Security Configuration (OFF = 0 and ON = 1):
Allow Remote Administrator = 0,
Network Clients = 0,
Transaction Manager Communication:
Allow Inbound Transactions = 0,
Allow Outbound Transactions = 0,
Transaction Internet Protocol (TIP) = 0,
Enable XA Transactions = 0,
Enable SNA LU 6.2 Transactions = 1,
MSDTC Communications Security = Mutual Authentication Required,
Account = NT AUTHORITY\NetworkService,
Firewall Exclusion Detected = 0
Transaction Bridge Installed = 0
Filtering Duplicate Events = 1
| 4202 | 0 | 16384 | 4 | 2 | 0 | 36028797018963968 | 392 | Microsoft-Windows-MSDTC 2 | 5d9e0020-3761-4f36-90c8-38ce6511bd12 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:25:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | TM | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 391 | cloudbase-init | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:24:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14397)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 390 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:24:32 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 389 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 556 | 796 | hv-osbrick-7736 | S-1-5-21-2967451136-4100737330-2698707467-1000 | 2/2/2021 9:24:30 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7736\Admin' in response to user profile creation. Error code 0x80070005.
Access is denied.
. | 6 | 0 | 49152 | 2 | 0 | 0 | 36028797018963968 | 388 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:24:30 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 387 | cloudbase-init | | Application | | | hv-osbrick-7736 | | 2/2/2021 9:23:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7736\cloudbase-init' .
| 5 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 386 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:23:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 385 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 1708 | hv-osbrick-7736 | | 2/2/2021 9:23:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 384 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 556 | 2004 | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:23:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 383 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:23:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 382 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:23:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Proof of Purchase installed successfully.
ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4
PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845 | 1016 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 381 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:23:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 380 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 556 | 1196 | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:23:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Delete for component {D63AA156-D534-4BAC-9BF1-55359CF5EC30} failed, error code is The system cannot find the path specified.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 379 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 556 | 544 | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:23:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 378 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 556 | 1656 | hv-osbrick-7736 | S-1-5-18 | 2/2/2021 9:23:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 377 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | hv-osbrick-7736 | | 2/2/2021 9:23:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 376 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 528 | 1504 | WIN-5T344G8GM1H | S-1-5-18 | 2/2/2021 9:23:03 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 375 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 2/2/2021 9:23:03 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The VSS service is shutting down due to shutdown event from the Service Control Manager. | 8225 | | 0 | 4 | 0 | | 36028797018963968 | 374 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/2/2021 9:23:03 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM. | 4112 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 373 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1732 | 1832 | WIN-5T344G8GM1H | | 2/2/2021 9:21:52 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de}
Writer Name: Microsoft Hyper-V VSS Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 372 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/2/2021 9:21:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 371 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 528 | 604 | WIN-5T344G8GM1H | S-1-5-18 | 2/2/2021 9:21:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 370 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 528 | 1608 | WIN-5T344G8GM1H | S-1-5-18 | 2/2/2021 9:21:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 369 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 528 | 1504 | WIN-5T344G8GM1H | S-1-5-18 | 2/2/2021 9:21:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f}
Writer Name: Shadow Copy Optimization Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 368 | VSS | | Application | | | WIN-UC257CA3CPR | | 2/2/2021 9:21:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4}
Writer Name: ASR Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 367 | VSS | | Application | | | WIN-UC257CA3CPR | | 2/2/2021 9:21:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f}
Writer Name: COM+ REGDB Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 366 | VSS | | Application | | | WIN-UC257CA3CPR | | 2/2/2021 9:21:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485}
Writer Name: Registry Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 365 | VSS | | Application | | | WIN-UC257CA3CPR | | 2/2/2021 9:21:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 364 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 1228 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required.
DETAIL -
9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500:
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore
Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main
Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security
| 1530 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 363 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 3432 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The winlogon notification subscriber <SessionEnv> failed a notification event. | 6001 | 0 | 32768 | 3 | 0 | 0 | 36028797018963968 | 362 | Microsoft-Windows-Winlogon | dbe9b383-7cf3-4331-91cc-a3cb16a3b538 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 361 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448 | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 360 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 359 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining. | 12306 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 358 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 357 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 356 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Grace period has been started. Grace days=10 Grace type=6. | 1025 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 355 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 354 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The hardware has changed. | 1024 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 353 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Hardware has changed from previous boot.
AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4. | 1040 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 352 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 351 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=Sysprep.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 350 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MS DTC service is stopping. | 4111 | 0 | 16384 | 4 | 1 | 0 | 36028797018963968 | 349 | Microsoft-Windows-MSDTC | 719be4ed-e9bc-4dd8-a7cf-c85ce8e4975d | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:47:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | SVC | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |