Message | Id | Version | Qualifiers | Level | Task | Opcode | Keywords | RecordId | ProviderName | ProviderId | LogName | ProcessId | ThreadId | MachineName | UserId | TimeCreated | ActivityId | RelatedActivityId | ContainerLog | MatchedQueryIds | Bookmark | LevelDisplayName | OpcodeDisplayName | TaskDisplayName | KeywordsDisplayNames | Properties |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 600 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:43:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-01-19T19:42:18Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 599 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:43:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 598 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:42:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259144 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 597 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:42:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259144)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 596 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:42:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 595 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:42:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 594 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:42:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 593 | neutron-ovs-agent | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:33:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 592 | cinder-volume | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:33:33 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 591 | nova-compute | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:33:30 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 590 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 4624 | 4340 | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 7:16:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 589 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:13:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-01-19T19:12:18Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 588 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:13:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 587 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:12:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259174 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 586 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:12:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 585 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:12:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 584 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:12:47 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 583 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 7:12:47 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2c10
Analysis symbol:
Rechecking for solution: 0
Report Id: 85812ef2-f0bf-4d9e-b241-205ad92fc619
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 582 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:26 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2b35
Analysis symbol:
Rechecking for solution: 0
Report Id: ea6e1702-b1a4-42f6-95b1-10a2f9d4c284
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 581 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:26 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2a79
Analysis symbol:
Rechecking for solution: 0
Report Id: 5a2a3899-78b8-49eb-ad19-ff71e84d1b2b
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 580 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:26 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc299f
Analysis symbol:
Rechecking for solution: 0
Report Id: 205d500d-29d9-4b7b-8ba8-b0363e0b5df8
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 579 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:26 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc26b1
Analysis symbol:
Rechecking for solution: 0
Report Id: 2a7b17bb-90c6-4722-9451-994d8ec46497
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 578 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc25f5
Analysis symbol:
Rechecking for solution: 0
Report Id: 71006505-f21e-4b24-9448-bd9e3ebac43e
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 577 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc250b
Analysis symbol:
Rechecking for solution: 0
Report Id: 53635a47-dc85-4566-a9b4-c2261b62bebe
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 576 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc22a9
Analysis symbol:
Rechecking for solution: 0
Report Id: 0350ad60-8598-48ab-89f9-155dada4788d
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 575 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc21cf
Analysis symbol:
Rechecking for solution: 0
Report Id: a86a9c0d-d66c-4b99-82c3-1a631cbcde6c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 574 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2103
Analysis symbol:
Rechecking for solution: 0
Report Id: c10aa9aa-b75e-4144-ad7d-78a3464abffe
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 573 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc2019
Analysis symbol:
Rechecking for solution: 0
Report Id: f97d79ff-aeb8-42c3-9502-e3bd1cfcccb9
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 572 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1f1f
Analysis symbol:
Rechecking for solution: 0
Report Id: dbf87b57-4146-48c4-81d1-21123c5829e1
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 571 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1c70
Analysis symbol:
Rechecking for solution: 0
Report Id: 039bde9e-034d-419f-9d86-e91f23dec397
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 570 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1ba4
Analysis symbol:
Rechecking for solution: 0
Report Id: aab4c644-cb16-4b2c-a7da-844f1d05ea02
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 569 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc1aca
Analysis symbol:
Rechecking for solution: 0
Report Id: cb5ab446-7a10-4987-97a0-9c76fd6be489
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 568 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc19c0
Analysis symbol:
Rechecking for solution: 0
Report Id: 660ce99c-8f2a-49fe-8b57-d6310d0c1bdc
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 567 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc18e5
Analysis symbol:
Rechecking for solution: 0
Report Id: ee00823e-e526-408a-ae4a-bca74a52b5e5
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 566 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a141839
Analysis symbol:
Rechecking for solution: 0
Report Id: 894bce04-6383-40bc-9d68-e8d459d4daec
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 565 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc15f7
Analysis symbol:
Rechecking for solution: 0
Report Id: 110a9aee-eb06-4326-8f06-33392d12b59c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 564 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x678
Faulting application start time: 0x01d6edccba6bde9f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 894bce04-6383-40bc-9d68-e8d459d4daec
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 563 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06dc157a
Analysis symbol:
Rechecking for solution: 0
Report Id: 8e9abd4a-211f-44dc-aab8-e0bf13d49fe8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 562 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x450
Faulting application start time: 0x01d6edccb9ff0a3d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 8e9abd4a-211f-44dc-aab8-e0bf13d49fe8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 561 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc12fa
Analysis symbol:
Rechecking for solution: 0
Report Id: 5ce6182c-7afc-4340-b9b9-4b48091a4029
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 560 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12c012ac
Analysis symbol:
Rechecking for solution: 0
Report Id: 719f1a81-7845-47e6-bf85-596e51378034
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 559 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1394
Faulting application start time: 0x01d6edccb9e6432b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 719f1a81-7845-47e6-bf85-596e51378034
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 558 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc11e0
Analysis symbol:
Rechecking for solution: 0
Report Id: 1a8c49b8-06c5-4354-b5d1-87c129a6df6f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 557 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0fd411f0
Analysis symbol:
Rechecking for solution: 0
Report Id: 5e895eba-2ab7-4584-9af0-277d92a191c2
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 556 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x134c
Faulting application start time: 0x01d6edccb9ca430c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5e895eba-2ab7-4584-9af0-277d92a191c2
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 555 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10d01144
Analysis symbol:
Rechecking for solution: 0
Report Id: bacddc87-2634-4fea-a575-9802c960298a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 554 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1044
Faulting application start time: 0x01d6edccb95a54a6
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: bacddc87-2634-4fea-a575-9802c960298a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 553 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10f80e75
Analysis symbol:
Rechecking for solution: 0
Report Id: c30d63f6-4150-451e-ae50-5a93654d6bf7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 552 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1028
Faulting application start time: 0x01d6edccb9421e56
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c30d63f6-4150-451e-ae50-5a93654d6bf7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 551 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10f40dca
Analysis symbol:
Rechecking for solution: 0
Report Id: 85812ef2-f0bf-4d9e-b241-205ad92fc619
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 550 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180d8b
Analysis symbol:
Rechecking for solution: 0
Report Id: d15b9e0e-bc09-450b-be28-ec2fa82d19ec
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 549 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x126c
Faulting application start time: 0x01d6edccb924dc0e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 85812ef2-f0bf-4d9e-b241-205ad92fc619
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 548 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02880d0e
Analysis symbol:
Rechecking for solution: 0
Report Id: ea6e1702-b1a4-42f6-95b1-10a2f9d4c284
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 547 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1088
Faulting application start time: 0x01d6edccb9094b44
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ea6e1702-b1a4-42f6-95b1-10a2f9d4c284
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 546 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180c81
Analysis symbol:
Rechecking for solution: 0
Report Id: 0260d5d2-f380-4f4f-a5c5-9ce9c94838bd
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 545 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_130c0c62
Analysis symbol:
Rechecking for solution: 0
Report Id: 5a2a3899-78b8-49eb-ad19-ff71e84d1b2b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 544 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11bc
Faulting application start time: 0x01d6edccb8f141b2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5a2a3899-78b8-49eb-ad19-ff71e84d1b2b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 543 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180bb6
Analysis symbol:
Rechecking for solution: 0
Report Id: 4b967442-a431-4427-b65b-b43b74fe53d6
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 542 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13a40ba7
Analysis symbol:
Rechecking for solution: 0
Report Id: 205d500d-29d9-4b7b-8ba8-b0363e0b5df8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 541 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1148
Faulting application start time: 0x01d6edccb8d4aac5
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 205d500d-29d9-4b7b-8ba8-b0363e0b5df8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 540 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08000b0a
Analysis symbol:
Rechecking for solution: 0
Report Id: 2a7b17bb-90c6-4722-9451-994d8ec46497
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 539 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180adc
Analysis symbol:
Rechecking for solution: 0
Report Id: c42f619e-32d8-42fd-9d0c-59c7939ba968
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 538 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1138
Faulting application start time: 0x01d6edccb8bc7e76
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2a7b17bb-90c6-4722-9451-994d8ec46497
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 537 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f5c0a6e
Analysis symbol:
Rechecking for solution: 0
Report Id: 71006505-f21e-4b24-9448-bd9e3ebac43e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 536 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x938
Faulting application start time: 0x01d6edccb8a38341
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 71006505-f21e-4b24-9448-bd9e3ebac43e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 535 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_101809f1
Analysis symbol:
Rechecking for solution: 0
Report Id: 2b297204-a4dc-4699-a15c-c55aaf100c04
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 534 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a8c09c2
Analysis symbol:
Rechecking for solution: 0
Report Id: 53635a47-dc85-4566-a9b4-c2261b62bebe
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 533 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xaf0
Faulting application start time: 0x01d6edccb88ac455
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 53635a47-dc85-4566-a9b4-c2261b62bebe
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 532 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_101808e8
Analysis symbol:
Rechecking for solution: 0
Report Id: 2f7d0c47-b42c-4cb3-b863-70fc370b6f50
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 531 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10e408f7
Analysis symbol:
Rechecking for solution: 0
Report Id: 0350ad60-8598-48ab-89f9-155dada4788d
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 530 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe68
Faulting application start time: 0x01d6edccb86f5398
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0350ad60-8598-48ab-89f9-155dada4788d
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 529 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1020086b
Analysis symbol:
Rechecking for solution: 0
Report Id: a86a9c0d-d66c-4b99-82c3-1a631cbcde6c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 528 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x578
Faulting application start time: 0x01d6edccb856bc94
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a86a9c0d-d66c-4b99-82c3-1a631cbcde6c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 527 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_101807ee
Analysis symbol:
Rechecking for solution: 0
Report Id: 180c72a4-3110-4671-aafb-66a28bdcd1f3
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 526 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_009807ce
Analysis symbol:
Rechecking for solution: 0
Report Id: c10aa9aa-b75e-4144-ad7d-78a3464abffe
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 525 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11a8
Faulting application start time: 0x01d6edccb83dc46b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c10aa9aa-b75e-4144-ad7d-78a3464abffe
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 524 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_101806f4
Analysis symbol:
Rechecking for solution: 0
Report Id: 1d3629e7-c0dd-4382-85f8-b33ed0fd6a50
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 523 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11fc0732
Analysis symbol:
Rechecking for solution: 0
Report Id: f97d79ff-aeb8-42c3-9502-e3bd1cfcccb9
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 522 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1380
Faulting application start time: 0x01d6edccb825bd81
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f97d79ff-aeb8-42c3-9502-e3bd1cfcccb9
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 521 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_139c0686
Analysis symbol:
Rechecking for solution: 0
Report Id: dbf87b57-4146-48c4-81d1-21123c5829e1
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 520 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xbf0
Faulting application start time: 0x01d6edccb80bd3d1
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: dbf87b57-4146-48c4-81d1-21123c5829e1
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 519 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180619
Analysis symbol:
Rechecking for solution: 0
Report Id: 74729eea-ad71-468e-ab9f-5e979ee79d18
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 518 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_044c05da
Analysis symbol:
Rechecking for solution: 0
Report Id: 039bde9e-034d-419f-9d86-e91f23dec397
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 517 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x5c4
Faulting application start time: 0x01d6edccb7f3883c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 039bde9e-034d-419f-9d86-e91f23dec397
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 516 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1018030c
Analysis symbol:
Rechecking for solution: 0
Report Id: ee2e6269-241b-4efb-ad3e-d0ccb82f3498
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 515 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13f4031b
Analysis symbol:
Rechecking for solution: 0
Report Id: aab4c644-cb16-4b2c-a7da-844f1d05ea02
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 514 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12a0
Faulting application start time: 0x01d6edccb786c5e0
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: aab4c644-cb16-4b2c-a7da-844f1d05ea02
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 513 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e180260
Analysis symbol:
Rechecking for solution: 0
Report Id: cb5ab446-7a10-4987-97a0-9c76fd6be489
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 512 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180240
Analysis symbol:
Rechecking for solution: 0
Report Id: 3e5d234f-0782-4bda-9bf3-014ed8fc24b1
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 511 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1038
Faulting application start time: 0x01d6edccb76a7ffd
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: cb5ab446-7a10-4987-97a0-9c76fd6be489
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 510 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_047401c3
Analysis symbol:
Rechecking for solution: 0
Report Id: 660ce99c-8f2a-49fe-8b57-d6310d0c1bdc
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 509 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1280
Faulting application start time: 0x01d6edccb6ff50a3
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 660ce99c-8f2a-49fe-8b57-d6310d0c1bdc
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 508 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10180166
Analysis symbol:
Rechecking for solution: 0
Report Id: d5b65204-f1a8-4ffb-82f5-f2a898813a47
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 507 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_105fff04
Analysis symbol:
Rechecking for solution: 0
Report Id: ee00823e-e526-408a-ae4a-bca74a52b5e5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 506 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1394
Faulting application start time: 0x01d6edccb6e70f5b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ee00823e-e526-408a-ae4a-bca74a52b5e5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 505 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_135ffe58
Analysis symbol:
Rechecking for solution: 0
Report Id: 110a9aee-eb06-4326-8f06-33392d12b59c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 504 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10b0
Faulting application start time: 0x01d6edccb6ccbe4c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 110a9aee-eb06-4326-8f06-33392d12b59c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 503 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f27fd9d
Analysis symbol:
Rechecking for solution: 0
Report Id: 5ce6182c-7afc-4340-b9b9-4b48091a4029
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 502 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10c4
Faulting application start time: 0x01d6edccb6afb9da
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5ce6182c-7afc-4340-b9b9-4b48091a4029
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 501 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bb3fcf1
Analysis symbol:
Rechecking for solution: 0
Report Id: 1a8c49b8-06c5-4354-b5d1-87c129a6df6f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 500 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xc34
Faulting application start time: 0x01d6edccb6974add
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1a8c49b8-06c5-4354-b5d1-87c129a6df6f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 499 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_021ffc55
Analysis symbol:
Rechecking for solution: 0
Report Id: d15b9e0e-bc09-450b-be28-ec2fa82d19ec
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 498 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ffc45
Analysis symbol:
Rechecking for solution: 0
Report Id: 0bc3e83c-816b-4c23-af50-932295fa2bf2
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 497 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xfb4
Faulting application start time: 0x01d6edccb67ef107
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d15b9e0e-bc09-450b-be28-ec2fa82d19ec
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 496 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e33fbb9
Analysis symbol:
Rechecking for solution: 0
Report Id: 0260d5d2-f380-4f4f-a5c5-9ce9c94838bd
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 495 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xeec
Faulting application start time: 0x01d6edccb6665832
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0260d5d2-f380-4f4f-a5c5-9ce9c94838bd
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 494 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ffb4b
Analysis symbol:
Rechecking for solution: 0
Report Id: a6553588-ecc0-4cd6-8a94-f2305be8d7d7
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 493 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11dbf909
Analysis symbol:
Rechecking for solution: 0
Report Id: 4b967442-a431-4427-b65b-b43b74fe53d6
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 492 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ff8da
Analysis symbol:
Rechecking for solution: 0
Report Id: 738368cb-3c73-4b6a-8367-25aada603a2f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 491 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1158
Faulting application start time: 0x01d6edccb5fcf374
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4b967442-a431-4427-b65b-b43b74fe53d6
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 490 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13c3f85d
Analysis symbol:
Rechecking for solution: 0
Report Id: c42f619e-32d8-42fd-9d0c-59c7939ba968
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 489 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10e4
Faulting application start time: 0x01d6edccb5e31cf0
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c42f619e-32d8-42fd-9d0c-59c7939ba968
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 488 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ff7ff
Analysis symbol:
Rechecking for solution: 0
Report Id: 396623f7-22c4-4bba-a65e-97759ec9a51f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 487 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_100ff7c1
Analysis symbol:
Rechecking for solution: 0
Report Id: 2b297204-a4dc-4699-a15c-c55aaf100c04
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 486 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1240
Faulting application start time: 0x01d6edccb5c83236
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2b297204-a4dc-4699-a15c-c55aaf100c04
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 485 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ff734
Analysis symbol:
Rechecking for solution: 0
Report Id: 267c6c2b-b1a2-4ad4-ad45-6eb2e4751159
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 484 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1147f6f6
Analysis symbol:
Rechecking for solution: 0
Report Id: 2f7d0c47-b42c-4cb3-b863-70fc370b6f50
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 483 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xc4c
Faulting application start time: 0x01d6edccb5ac8cf2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2f7d0c47-b42c-4cb3-b863-70fc370b6f50
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 482 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ff62b
Analysis symbol:
Rechecking for solution: 0
Report Id: d103474b-a5ad-4aed-b53a-b7965b5f2ffe
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 481 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13bbf64a
Analysis symbol:
Rechecking for solution: 0
Report Id: 180c72a4-3110-4671-aafb-66a28bdcd1f3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 480 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11f0
Faulting application start time: 0x01d6edccb59114c2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 180c72a4-3110-4671-aafb-66a28bdcd1f3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 479 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_07fbf59e
Analysis symbol:
Rechecking for solution: 0
Report Id: 1d3629e7-c0dd-4382-85f8-b33ed0fd6a50
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 478 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ff540
Analysis symbol:
Rechecking for solution: 0
Report Id: 53cd5171-7100-4359-9a78-5bd48b378006
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 477 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xbcc
Faulting application start time: 0x01d6edccb576ef2e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1d3629e7-c0dd-4382-85f8-b33ed0fd6a50
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 476 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ad3f4f2
Analysis symbol:
Rechecking for solution: 0
Report Id: 74729eea-ad71-468e-ab9f-5e979ee79d18
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 475 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x61c
Faulting application start time: 0x01d6edccb5570127
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 74729eea-ad71-468e-ab9f-5e979ee79d18
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 474 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a1ff475
Analysis symbol:
Rechecking for solution: 0
Report Id: e7608e6b-82ba-493b-a752-4b15cc4fbff2
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 473 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1273f3f8
Analysis symbol:
Rechecking for solution: 0
Report Id: ee2e6269-241b-4efb-ad3e-d0ccb82f3498
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 472 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x6d4
Faulting application start time: 0x01d6edccb5375c2c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ee2e6269-241b-4efb-ad3e-d0ccb82f3498
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 471 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_116ff33d
Analysis symbol:
Rechecking for solution: 0
Report Id: 3e5d234f-0782-4bda-9bf3-014ed8fc24b1
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 470 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1020
Faulting application start time: 0x01d6edccb51a90a2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 3e5d234f-0782-4bda-9bf3-014ed8fc24b1
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 469 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ebff2a0
Analysis symbol:
Rechecking for solution: 0
Report Id: d5b65204-f1a8-4ffb-82f5-f2a898813a47
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 468 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x7cc
Faulting application start time: 0x01d6edccb4adc5e5
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d5b65204-f1a8-4ffb-82f5-f2a898813a47
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 467 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02b3efb2
Analysis symbol:
Rechecking for solution: 0
Report Id: 0bc3e83c-816b-4c23-af50-932295fa2bf2
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 466 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:11 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xbac
Faulting application start time: 0x01d6edccb492b8ed
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0bc3e83c-816b-4c23-af50-932295fa2bf2
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 465 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:11 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f5fef45
Analysis symbol:
Rechecking for solution: 0
Report Id: 08c4dac5-a619-4bff-a217-402f850e66b5
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 464 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:11 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_01cfef16
Analysis symbol:
Rechecking for solution: 0
Report Id: a6553588-ecc0-4cd6-8a94-f2305be8d7d7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 463 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:11 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x778
Faulting application start time: 0x01d6edccb479fe3c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a6553588-ecc0-4cd6-8a94-f2305be8d7d7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 462 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:11 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02fbee7a
Analysis symbol:
Rechecking for solution: 0
Report Id: 738368cb-3c73-4b6a-8367-25aada603a2f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 461 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:11 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x820
Faulting application start time: 0x01d6edccb460fd89
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 738368cb-3c73-4b6a-8367-25aada603a2f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 460 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:10 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1247edde
Analysis symbol:
Rechecking for solution: 0
Report Id: 396623f7-22c4-4bba-a65e-97759ec9a51f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 459 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:10 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x64
Faulting application start time: 0x01d6edccb4483eac
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 396623f7-22c4-4bba-a65e-97759ec9a51f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 458 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:10 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10e7ed22
Analysis symbol:
Rechecking for solution: 0
Report Id: 267c6c2b-b1a2-4ad4-ad45-6eb2e4751159
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 457 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:10 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x840
Faulting application start time: 0x01d6edccb3dd306d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 267c6c2b-b1a2-4ad4-ad45-6eb2e4751159
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 456 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:10 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06dfea63
Analysis symbol:
Rechecking for solution: 0
Report Id: d103474b-a5ad-4aed-b53a-b7965b5f2ffe
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 455 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:09 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x440
Faulting application start time: 0x01d6edccb3bced7f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d103474b-a5ad-4aed-b53a-b7965b5f2ffe
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 454 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:09 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10a7e9a8
Analysis symbol:
Rechecking for solution: 0
Report Id: 53cd5171-7100-4359-9a78-5bd48b378006
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 453 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:09 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?01?-?18T19:04:02.630551200Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 452 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4596 | 1416 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 7:04:08 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x2f8
Faulting application start time: 0x01d6edccb350bb9d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 53cd5171-7100-4359-9a78-5bd48b378006
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 451 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:09 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0367e6d9
Analysis symbol:
Rechecking for solution: 0
Report Id: e7608e6b-82ba-493b-a752-4b15cc4fbff2
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 450 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:09 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x454
Faulting application start time: 0x01d6edccb33734d4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e7608e6b-82ba-493b-a752-4b15cc4fbff2
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 449 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:09 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bebe62d
Analysis symbol:
Rechecking for solution: 0
Report Id: 08c4dac5-a619-4bff-a217-402f850e66b5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 448 | Windows Error Reporting | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:08 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 5060. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 447 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 7:04:08 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 446 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 7:04:08 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 445 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 7:04:08 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1124
Faulting application start time: 0x01d6edccb29afa5e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 08c4dac5-a619-4bff-a217-402f850e66b5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 444 | Application Error | | Application | | | hv-osbrick-7695 | | 1/18/2021 7:04:08 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?01?-?18T19:04:02.630551200Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 443 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4596 | 4656 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 7:04:02 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 5060. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 442 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 7:04:02 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 441 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 176 | hv-osbrick-7695 | | 1/18/2021 7:03:54 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root list with effective date: ?Monday, ?October ?12, ?2020 9:49:04 PM. | 4111 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 440 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 439 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 438 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 437 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 436 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 435 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 434 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 433 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 4688 | hv-osbrick-7695 | | 1/18/2021 6:54:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 432 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 4868 | 4872 | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:48:41 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?01?-?18T18:48:34.444297100Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 431 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2136 | 2212 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4824. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 430 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:48:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 429 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 428 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?01?-?18T18:48:34.444297100Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 427 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2136 | 968 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?01?-?18T18:48:33.896981900Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 426 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2136 | 2212 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?01?-?18T18:48:33.896981900Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 425 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 2136 | 4284 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:33 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4824. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 424 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4824. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 423 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:48:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 422 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 421 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4824. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 420 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:48:33 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0. | 1035 | | 0 | 4 | 0 | | 36028797018963968 | 419 | MsiInstaller | | Application | | | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:48:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?01?-?18T18:47:48.881457800Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 418 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 968 | 4036 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:47:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?01?-?18T18:47:48.881457800Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 417 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 968 | 4036 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1001 | 1/18/2021 6:47:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 416 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 3092 | hv-osbrick-7695 | | 1/18/2021 6:47:07 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 415 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-01-19T18:45:53Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 414 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 413 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/07/17:18:46:22;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 412 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 411 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259200 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 410 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 409 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 408 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
These policies are being excluded since they are only defined with override-only attribute.
Policy Names=(Security-SPP-Reserved-EnableNotificationMode)
App Id=55c92734-d682-4d71-983e-d6ec3f16059f
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1033 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 407 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 406 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Validity period has been started. Validity minutes=259200 Grace type=9. | 1036 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 405 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MSA client has been successfully triggered to update the Device License | 12311 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 404 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f} | 12304 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 403 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f | 12305 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 402 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection ended.
| 20489 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 401 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 400 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check passed.
| 20482 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 399 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check initiated.
| 20481 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 398 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection started.
| 20488 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 397 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS.
| 1067 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 396 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE}
License Id=f43a31c1-da83-4469-b26c-e7accdaf7259 | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 395 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC}
License Id=3ac600e1-6830-428d-85ad-7941f9560e8b | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 394 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Acquisition of End User License was successful.
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1013 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 393 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 392 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 1692 | hv-osbrick-7695 | | 1/18/2021 6:46:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/01/28:18:42:09;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 391 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:46:10 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
MSDTC started with the following settings:
Security Configuration (OFF = 0 and ON = 1):
Allow Remote Administrator = 0,
Network Clients = 0,
Transaction Manager Communication:
Allow Inbound Transactions = 0,
Allow Outbound Transactions = 0,
Transaction Internet Protocol (TIP) = 0,
Enable XA Transactions = 0,
Enable SNA LU 6.2 Transactions = 1,
MSDTC Communications Security = Mutual Authentication Required,
Account = NT AUTHORITY\NetworkService,
Firewall Exclusion Detected = 0
Transaction Bridge Installed = 0
Filtering Duplicate Events = 1
| 4202 | 0 | 16384 | 4 | 2 | 0 | 36028797018963968 | 390 | Microsoft-Windows-MSDTC 2 | 5d9e0020-3761-4f36-90c8-38ce6511bd12 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:44:49 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | TM | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 389 | cloudbase-init | | Application | | | hv-osbrick-7695 | | 1/18/2021 6:43:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 388 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:43:34 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 387 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 612 | 2500 | hv-osbrick-7695 | S-1-5-21-4163937796-3708339498-3253859500-1000 | 1/18/2021 6:43:33 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7695\Admin' in response to user profile creation. Error code 0x80070005.
Access is denied.
. | 6 | 0 | 49152 | 2 | 0 | 0 | 36028797018963968 | 386 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:43:33 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 385 | cloudbase-init | | Application | | | hv-osbrick-7695 | | 1/18/2021 6:42:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7695\cloudbase-init' .
| 5 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 384 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:42:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 383 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1332 | 1692 | hv-osbrick-7695 | | 1/18/2021 6:42:50 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 382 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 612 | 496 | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:42:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 381 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 612 | 1288 | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:42:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 380 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 612 | 1728 | hv-osbrick-7695 | S-1-5-18 | 1/18/2021 6:42:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 379 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:42:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 378 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:42:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Proof of Purchase installed successfully.
ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4
PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845 | 1016 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 377 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:42:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 376 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | hv-osbrick-7695 | | 1/18/2021 6:42:46 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 375 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 540 | 1508 | WIN-5T344G8GM1H | S-1-5-18 | 1/18/2021 6:42:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 374 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/18/2021 6:42:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de}
Writer Name: Microsoft Hyper-V VSS Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 373 | VSS | | Application | | | WIN-5T344G8GM1H | | 1/18/2021 6:41:29 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM. | 4112 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 372 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1744 | 1824 | WIN-5T344G8GM1H | | 1/18/2021 6:41:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 371 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 540 | 580 | WIN-5T344G8GM1H | S-1-5-18 | 1/18/2021 6:41:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 370 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 540 | 1608 | WIN-5T344G8GM1H | S-1-5-18 | 1/18/2021 6:41:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 369 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 540 | 1508 | WIN-5T344G8GM1H | S-1-5-18 | 1/18/2021 6:41:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f}
Writer Name: Shadow Copy Optimization Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 368 | VSS | | Application | | | WIN-5T344G8GM1H | | 1/18/2021 6:41:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4}
Writer Name: ASR Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 367 | VSS | | Application | | | WIN-5T344G8GM1H | | 1/18/2021 6:41:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f}
Writer Name: COM+ REGDB Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 366 | VSS | | Application | | | WIN-5T344G8GM1H | | 1/18/2021 6:41:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485}
Writer Name: Registry Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 365 | VSS | | Application | | | WIN-5T344G8GM1H | | 1/18/2021 6:41:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 364 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 1228 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required.
DETAIL -
9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500:
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore
Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main
Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security
| 1530 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 363 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 3432 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The winlogon notification subscriber <SessionEnv> failed a notification event. | 6001 | 0 | 32768 | 3 | 0 | 0 | 36028797018963968 | 362 | Microsoft-Windows-Winlogon | dbe9b383-7cf3-4331-91cc-a3cb16a3b538 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 361 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448 | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 360 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 359 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining. | 12306 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 358 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 357 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 356 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Grace period has been started. Grace days=10 Grace type=6. | 1025 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 355 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 354 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The hardware has changed. | 1024 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 353 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Hardware has changed from previous boot.
AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4. | 1040 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 352 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 351 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=Sysprep.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 350 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MS DTC service is stopping. | 4111 | 0 | 16384 | 4 | 1 | 0 | 36028797018963968 | 349 | Microsoft-Windows-MSDTC | 719be4ed-e9bc-4dd8-a7cf-c85ce8e4975d | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:47:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | SVC | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |