MessageIdVersionQualifiersLevelTaskOpcodeKeywordsRecordIdProviderNameProviderIdLogNameProcessIdThreadIdMachineNameUserIdTimeCreatedActivityIdRelatedActivityIdContainerLogMatchedQueryIdsBookmarkLevelDisplayNameOpcodeDisplayNameTaskDisplayNameKeywordsDisplayNamesProperties
004036028797018963968584neutron-ovs-agentApplicationhv-osbrick-766712/12/2020 2:29:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968583cinder-volumeApplicationhv-osbrick-766712/12/2020 2:29:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968582nova-computeApplicationhv-osbrick-766712/12/2020 2:29:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968581Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-13T14:16:51Z. Reason: TBL.1638401638440036028797018963968580Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968579Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259174 minutes.103703276840036028797018963968578Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968577Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968576Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968575Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 2:17:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808574Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application41365100hv-osbrick-7667S-1-5-1812/12/2020 2:15:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e586728 Analysis symbol: Rechecking for solution: 0 Report Id: d0056288-dd86-441f-8a8c-b5327633b4e2 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968573Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e58663e Analysis symbol: Rechecking for solution: 0 Report Id: 60f60d2f-8339-4dd5-b5e7-1cc3884adbe0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968572Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e586515 Analysis symbol: Rechecking for solution: 0 Report Id: 65037cc4-1d02-40b1-8ad5-61102338a87c Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968571Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e58644a Analysis symbol: Rechecking for solution: 0 Report Id: 1ec8ae99-dc2f-4383-9a4d-739761fb4722 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968570Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e58635f Analysis symbol: Rechecking for solution: 0 Report Id: f770428c-a533-455e-9acc-be930a343f9f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968569Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e586275 Analysis symbol: Rechecking for solution: 0 Report Id: c5d14f94-fdb2-45bd-9b71-0769768cb03e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968568Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e58618a Analysis symbol: Rechecking for solution: 0 Report Id: 6a290c77-8563-41f2-b109-aaf2022f81c3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968567Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e586090 Analysis symbol: Rechecking for solution: 0 Report Id: c98e96f6-115f-4aab-9cfe-76b5943bc8e4 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968566Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585fa6 Analysis symbol: Rechecking for solution: 0 Report Id: 938e94a9-44e5-4019-936a-a45d6c76e723 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968565Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585ebc Analysis symbol: Rechecking for solution: 0 Report Id: d2981f9c-a1a7-41af-af66-b56c0d45f061 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968564Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585dd1 Analysis symbol: Rechecking for solution: 0 Report Id: 4dfb295d-6f98-438e-a277-9b92cfd7146d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968563Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585d06 Analysis symbol: Rechecking for solution: 0 Report Id: 9e9a0366-e816-44c7-8e0c-78181dfd3ab0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968562Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585c0c Analysis symbol: Rechecking for solution: 0 Report Id: 93e36ab9-912a-40c1-a409-65818cfc1e5f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968561Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585b31 Analysis symbol: Rechecking for solution: 0 Report Id: c3340b92-d247-4117-a678-552d5c3e707d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968560Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5859ca Analysis symbol: Rechecking for solution: 0 Report Id: 3bb0c717-6b01-44b4-8970-cbae5332e4a0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968559Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_128859e9 Analysis symbol: Rechecking for solution: 0 Report Id: 152b7129-bf31-44f3-85d6-333ec8c09e6a Report Status: 4 Hashed bucket: 100104036028797018963968558Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x115c Faulting application start time: 0x01d6d08fc210635f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 152b7129-bf31-44f3-85d6-333ec8c09e6a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968557Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c28593d Analysis symbol: Rechecking for solution: 0 Report Id: 0816eb25-81cc-4d4b-83c3-786b0892be13 Report Status: 4 Hashed bucket: 100104036028797018963968556Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5858b1 Analysis symbol: Rechecking for solution: 0 Report Id: 3acf017b-1e17-435e-bce4-ee0658750304 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968555Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x8f0 Faulting application start time: 0x01d6d08fc1f5c3a7 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0816eb25-81cc-4d4b-83c3-786b0892be13 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968554Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11885892 Analysis symbol: Rechecking for solution: 0 Report Id: 1f4584b4-705e-476a-a90d-46b196b08fcd Report Status: 4 Hashed bucket: 100104036028797018963968553Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x2a8 Faulting application start time: 0x01d6d08fc1dc3515 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1f4584b4-705e-476a-a90d-46b196b08fcd Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968552Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_119857e6 Analysis symbol: Rechecking for solution: 0 Report Id: 568885b1-f550-4309-a293-a01e107505a6 Report Status: 4 Hashed bucket: 100104036028797018963968551Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11c0 Faulting application start time: 0x01d6d08fc1c1aefa Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 568885b1-f550-4309-a293-a01e107505a6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968550Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13b8573a Analysis symbol: Rechecking for solution: 0 Report Id: c21a4ebe-4a2c-4bda-86f2-21f50db0e33a Report Status: 4 Hashed bucket: 100104036028797018963968549Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x8f8 Faulting application start time: 0x01d6d08fc1a8c6d2 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c21a4ebe-4a2c-4bda-86f2-21f50db0e33a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968548Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5856fb Analysis symbol: Rechecking for solution: 0 Report Id: baf741b9-94ea-4ed9-950a-166fbf21f31b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968547Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0eec568e Analysis symbol: Rechecking for solution: 0 Report Id: 987b38d2-c773-4e27-b8dd-5874e2f26303 Report Status: 4 Hashed bucket: 100104036028797018963968546Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10e0 Faulting application start time: 0x01d6d08fc18f84b5 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 987b38d2-c773-4e27-b8dd-5874e2f26303 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968545Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585601 Analysis symbol: Rechecking for solution: 0 Report Id: f73a278a-a5ad-4d59-a2d3-9cd21581e60f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968544Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06fc55f2 Analysis symbol: Rechecking for solution: 0 Report Id: e1273bc3-4d5e-4a4d-ac10-2fd8524cfb3a Report Status: 4 Hashed bucket: 100104036028797018963968543Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xed0 Faulting application start time: 0x01d6d08fc1755156 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e1273bc3-4d5e-4a4d-ac10-2fd8524cfb3a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968542Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08505536 Analysis symbol: Rechecking for solution: 0 Report Id: 99f9d2c4-85b4-4463-92c8-dac520f05396 Report Status: 4 Hashed bucket: 100104036028797018963968541Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5854f8 Analysis symbol: Rechecking for solution: 0 Report Id: 3dac1398-3669-4a6e-aab1-887135e943ab Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968540Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1394 Faulting application start time: 0x01d6d08fc15acaeb Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 99f9d2c4-85b4-4463-92c8-dac520f05396 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968539Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_133c549a Analysis symbol: Rechecking for solution: 0 Report Id: 118e0d20-c05a-4340-9136-79722f318d8b Report Status: 4 Hashed bucket: 100104036028797018963968538Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xa8 Faulting application start time: 0x01d6d08fc141c968 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 118e0d20-c05a-4340-9136-79722f318d8b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968537Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a0c53fe Analysis symbol: Rechecking for solution: 0 Report Id: 0f837a81-cd38-4190-8e23-c1e7055f7cfe Report Status: 4 Hashed bucket: 100104036028797018963968536Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585390 Analysis symbol: Rechecking for solution: 0 Report Id: 96b3b8d5-2066-4556-90f2-f8e749ee3645 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968535Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x83c Faulting application start time: 0x01d6d08fc12994ab Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0f837a81-cd38-4190-8e23-c1e7055f7cfe Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968534Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_032c5342 Analysis symbol: Rechecking for solution: 0 Report Id: 317e5bf1-c1fe-4234-bcac-c920fb83c6c1 Report Status: 4 Hashed bucket: 100104036028797018963968533Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x122c Faulting application start time: 0x01d6d08fc110c6aa Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 317e5bf1-c1fe-4234-bcac-c920fb83c6c1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968532Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e585287 Analysis symbol: Rechecking for solution: 0 Report Id: 1620d23b-7040-48af-88af-6e6b64894d7d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968531Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f5452a6 Analysis symbol: Rechecking for solution: 0 Report Id: b137a465-dd5c-4598-9f10-91274c5f98ee Report Status: 4 Hashed bucket: 100104036028797018963968530Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1310 Faulting application start time: 0x01d6d08fc0f862c7 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: b137a465-dd5c-4598-9f10-91274c5f98ee Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968529Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d385219 Analysis symbol: Rechecking for solution: 0 Report Id: 01095898-ed64-4e33-b149-2255743abaa8 Report Status: 4 Hashed bucket: 100104036028797018963968528Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1388 Faulting application start time: 0x01d6d08fc0e0cfe6 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 01095898-ed64-4e33-b149-2255743abaa8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968527Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_116c517d Analysis symbol: Rechecking for solution: 0 Report Id: 15a910a6-bec3-4a5f-b1f1-08ccb239119e Report Status: 4 Hashed bucket: 100104036028797018963968526Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12b0 Faulting application start time: 0x01d6d08fc0c9365a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 15a910a6-bec3-4a5f-b1f1-08ccb239119e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968525Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ebc50e1 Analysis symbol: Rechecking for solution: 0 Report Id: e31b88d9-b60e-4aaf-aa86-aae6c6669512 Report Status: 4 Hashed bucket: 100104036028797018963968524Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x9f8 Faulting application start time: 0x01d6d08fc0b1bb17 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e31b88d9-b60e-4aaf-aa86-aae6c6669512 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968523Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10305035 Analysis symbol: Rechecking for solution: 0 Report Id: c43a1b5c-1847-4593-a453-94d03526628e Report Status: 4 Hashed bucket: 100104036028797018963968522Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xfd4 Faulting application start time: 0x01d6d08fc0978511 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c43a1b5c-1847-4593-a453-94d03526628e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968521Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_117c4f79 Analysis symbol: Rechecking for solution: 0 Report Id: d0056288-dd86-441f-8a8c-b5327633b4e2 Report Status: 4 Hashed bucket: 100104036028797018963968520Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44f5a Analysis symbol: Rechecking for solution: 0 Report Id: 71073b85-14bb-4a8c-a288-0d353a76d541 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968519Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x798 Faulting application start time: 0x01d6d08fc07c257e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d0056288-dd86-441f-8a8c-b5327633b4e2 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968518Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c604efc Analysis symbol: Rechecking for solution: 0 Report Id: 60f60d2f-8339-4dd5-b5e7-1cc3884adbe0 Report Status: 4 Hashed bucket: 100104036028797018963968517Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe50 Faulting application start time: 0x01d6d08fc0653758 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 60f60d2f-8339-4dd5-b5e7-1cc3884adbe0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968516Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44e51 Analysis symbol: Rechecking for solution: 0 Report Id: 43497b59-c60a-4d46-94b4-aae78e7db4a0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968515Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12144e51 Analysis symbol: Rechecking for solution: 0 Report Id: 65037cc4-1d02-40b1-8ad5-61102338a87c Report Status: 4 Hashed bucket: 100104036028797018963968514Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x133c Faulting application start time: 0x01d6d08fc04b35c4 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 65037cc4-1d02-40b1-8ad5-61102338a87c Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968513Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06584d95 Analysis symbol: Rechecking for solution: 0 Report Id: 1ec8ae99-dc2f-4383-9a4d-739761fb4722 Report Status: 4 Hashed bucket: 100104036028797018963968512Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44d18 Analysis symbol: Rechecking for solution: 0 Report Id: f4ea9c5b-ff87-4225-a419-bfc1eb6d0274 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968511Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1008 Faulting application start time: 0x01d6d08fc02df7be Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1ec8ae99-dc2f-4383-9a4d-739761fb4722 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968510Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_01904ce9 Analysis symbol: Rechecking for solution: 0 Report Id: f770428c-a533-455e-9acc-be930a343f9f Report Status: 4 Hashed bucket: 100104036028797018963968509Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1370 Faulting application start time: 0x01d6d08fc016b758 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f770428c-a533-455e-9acc-be930a343f9f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968508Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f044c4d Analysis symbol: Rechecking for solution: 0 Report Id: c5d14f94-fdb2-45bd-9b71-0769768cb03e Report Status: 4 Hashed bucket: 100104036028797018963968507Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44c1e Analysis symbol: Rechecking for solution: 0 Report Id: cbd8efa6-a09f-40be-bfd1-dfc20c03def2 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968506Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1358 Faulting application start time: 0x01d6d08fbfff6c1e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c5d14f94-fdb2-45bd-9b71-0769768cb03e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968505Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10204bc0 Analysis symbol: Rechecking for solution: 0 Report Id: 6a290c77-8563-41f2-b109-aaf2022f81c3 Report Status: 4 Hashed bucket: 100104036028797018963968504Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1154 Faulting application start time: 0x01d6d08fbfe828b4 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6a290c77-8563-41f2-b109-aaf2022f81c3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968503Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44b34 Analysis symbol: Rechecking for solution: 0 Report Id: fed796d4-5a87-4cba-87de-dc7d401165e9 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968502Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11ac4b14 Analysis symbol: Rechecking for solution: 0 Report Id: c98e96f6-115f-4aab-9cfe-76b5943bc8e4 Report Status: 4 Hashed bucket: 100104036028797018963968501Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1004 Faulting application start time: 0x01d6d08fbfcf2e4d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c98e96f6-115f-4aab-9cfe-76b5943bc8e4 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968500Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_09344a59 Analysis symbol: Rechecking for solution: 0 Report Id: 938e94a9-44e5-4019-936a-a45d6c76e723 Report Status: 4 Hashed bucket: 100104036028797018963968499Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44a0b Analysis symbol: Rechecking for solution: 0 Report Id: f333ed94-040a-41c0-a207-fde2831384c7 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968498Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1028 Faulting application start time: 0x01d6d08fbfb1b32c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 938e94a9-44e5-4019-936a-a45d6c76e723 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968497Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f44499d Analysis symbol: Rechecking for solution: 0 Report Id: d2981f9c-a1a7-41af-af66-b56c0d45f061 Report Status: 4 Hashed bucket: 100104036028797018963968496Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x5c4 Faulting application start time: 0x01d6d08fbf9584f9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d2981f9c-a1a7-41af-af66-b56c0d45f061 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968495Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_133c4911 Analysis symbol: Rechecking for solution: 0 Report Id: 4dfb295d-6f98-438e-a277-9b92cfd7146d Report Status: 4 Hashed bucket: 100104036028797018963968494Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1200 Faulting application start time: 0x01d6d08fbf7e586b Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 4dfb295d-6f98-438e-a277-9b92cfd7146d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968493Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44846 Analysis symbol: Rechecking for solution: 0 Report Id: a1880c32-2332-4e33-b33d-41c78106c239 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968492Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04fc4855 Analysis symbol: Rechecking for solution: 0 Report Id: 9e9a0366-e816-44c7-8e0c-78181dfd3ab0 Report Status: 4 Hashed bucket: 100104036028797018963968491Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x49c Faulting application start time: 0x01d6d08fbf63634c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9e9a0366-e816-44c7-8e0c-78181dfd3ab0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968490Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_104447b9 Analysis symbol: Rechecking for solution: 0 Report Id: 93e36ab9-912a-40c1-a409-65818cfc1e5f Report Status: 4 Hashed bucket: 100104036028797018963968489Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1220 Faulting application start time: 0x01d6d08fbf4ab1e0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 93e36ab9-912a-40c1-a409-65818cfc1e5f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968488Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1274470d Analysis symbol: Rechecking for solution: 0 Report Id: c3340b92-d247-4117-a678-552d5c3e707d Report Status: 4 Hashed bucket: 100104036028797018963968487Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1268 Faulting application start time: 0x01d6d08fbf331b94 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c3340b92-d247-4117-a678-552d5c3e707d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968486Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f544671 Analysis symbol: Rechecking for solution: 0 Report Id: 3bb0c717-6b01-44b4-8970-cbae5332e4a0 Report Status: 4 Hashed bucket: 100104036028797018963968485Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44652 Analysis symbol: Rechecking for solution: 0 Report Id: 52302825-6e58-4311-a3b1-50637ddbc6fd Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968484Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x4fc Faulting application start time: 0x01d6d08fbf198b8a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 3bb0c717-6b01-44b4-8970-cbae5332e4a0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968483Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_112445d5 Analysis symbol: Rechecking for solution: 0 Report Id: 3acf017b-1e17-435e-bce4-ee0658750304 Report Status: 4 Hashed bucket: 100104036028797018963968482Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xd28 Faulting application start time: 0x01d6d08fbf010714 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 3acf017b-1e17-435e-bce4-ee0658750304 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968481Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05c44529 Analysis symbol: Rechecking for solution: 0 Report Id: 5cadd0a8-64db-4046-82ce-efe85c15cfd3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968480Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12a04538 Analysis symbol: Rechecking for solution: 0 Report Id: baf741b9-94ea-4ed9-950a-166fbf21f31b Report Status: 4 Hashed bucket: 100104036028797018963968479Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1074 Faulting application start time: 0x01d6d08fbee9a356 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: baf741b9-94ea-4ed9-950a-166fbf21f31b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968478Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0efc449c Analysis symbol: Rechecking for solution: 0 Report Id: f73a278a-a5ad-4d59-a2d3-9cd21581e60f Report Status: 4 Hashed bucket: 100104036028797018963968477Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1348 Faulting application start time: 0x01d6d08fbecfd9c7 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f73a278a-a5ad-4d59-a2d3-9cd21581e60f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968476Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a7843e1 Analysis symbol: Rechecking for solution: 0 Report Id: 3dac1398-3669-4a6e-aab1-887135e943ab Report Status: 4 Hashed bucket: 100104036028797018963968475Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1304 Faulting application start time: 0x01d6d08fbeb84439 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 3dac1398-3669-4a6e-aab1-887135e943ab Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968474Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_01684354 Analysis symbol: Rechecking for solution: 0 Report Id: 96b3b8d5-2066-4556-90f2-f8e749ee3645 Report Status: 4 Hashed bucket: 100104036028797018963968473Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x814 Faulting application start time: 0x01d6d08fbea0d6cf Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 96b3b8d5-2066-4556-90f2-f8e749ee3645 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968472Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_112842a8 Analysis symbol: Rechecking for solution: 0 Report Id: 1620d23b-7040-48af-88af-6e6b64894d7d Report Status: 4 Hashed bucket: 100104036028797018963968471Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1244 Faulting application start time: 0x01d6d08fbe878ce8 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1620d23b-7040-48af-88af-6e6b64894d7d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968470Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03dc420c Analysis symbol: Rechecking for solution: 0 Report Id: 71073b85-14bb-4a8c-a288-0d353a76d541 Report Status: 4 Hashed bucket: 100104036028797018963968469Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06dc41cd Analysis symbol: Rechecking for solution: 0 Report Id: b8a39521-a9f4-477b-afec-671b2e4ae787 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968468Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x770 Faulting application start time: 0x01d6d08fbe6e7989 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 71073b85-14bb-4a8c-a288-0d353a76d541 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968467Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0dec4150 Analysis symbol: Rechecking for solution: 0 Report Id: 43497b59-c60a-4d46-94b4-aae78e7db4a0 Report Status: 4 Hashed bucket: 100104036028797018963968466Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x8c4 Faulting application start time: 0x01d6d08fbe511982 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 43497b59-c60a-4d46-94b4-aae78e7db4a0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968465Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ff040a5 Analysis symbol: Rechecking for solution: 0 Report Id: f4ea9c5b-ff87-4225-a419-bfc1eb6d0274 Report Status: 4 Hashed bucket: 100104036028797018963968464Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xa0c Faulting application start time: 0x01d6d08fbe396272 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f4ea9c5b-ff87-4225-a419-bfc1eb6d0274 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968463Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11384008 Analysis symbol: Rechecking for solution: 0 Report Id: cbd8efa6-a09f-40be-bfd1-dfc20c03def2 Report Status: 4 Hashed bucket: 100104036028797018963968462Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x5b4 Faulting application start time: 0x01d6d08fbe2232bd Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: cbd8efa6-a09f-40be-bfd1-dfc20c03def2 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968461Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?12T14:04:38.738430700Z.100010400-9223372036854775808460Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application24084120hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03ec3f6c Analysis symbol: Rechecking for solution: 0 Report Id: fed796d4-5a87-4cba-87de-dc7d401165e9 Report Status: 4 Hashed bucket: 100104036028797018963968459Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xd3c Faulting application start time: 0x01d6d08fbe08cbdb Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: fed796d4-5a87-4cba-87de-dc7d401165e9 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968458Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11c03edf Analysis symbol: Rechecking for solution: 0 Report Id: f333ed94-040a-41c0-a207-fde2831384c7 Report Status: 4 Hashed bucket: 100104036028797018963968457Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x104c Faulting application start time: 0x01d6d08fbdf0f286 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f333ed94-040a-41c0-a207-fde2831384c7 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968456Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13dc3e43 Analysis symbol: Rechecking for solution: 0 Report Id: a1880c32-2332-4e33-b33d-41c78106c239 Report Status: 4 Hashed bucket: 100104036028797018963968455Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1358 Faulting application start time: 0x01d6d08fbdd96213 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a1880c32-2332-4e33-b33d-41c78106c239 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968454Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11943d97 Analysis symbol: Rechecking for solution: 0 Report Id: 52302825-6e58-4311-a3b1-50637ddbc6fd Report Status: 4 Hashed bucket: 100104036028797018963968453Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x850 Faulting application start time: 0x01d6d08fbdc2b033 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 52302825-6e58-4311-a3b1-50637ddbc6fd Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968452Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0eb03d0b Analysis symbol: Rechecking for solution: 0 Report Id: 5cadd0a8-64db-4046-82ce-efe85c15cfd3 Report Status: 4 Hashed bucket: 100104036028797018963968451Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x8d4 Faulting application start time: 0x01d6d08fbdab43b7 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5cadd0a8-64db-4046-82ce-efe85c15cfd3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968450Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_133c3c6e Analysis symbol: Rechecking for solution: 0 Report Id: b8a39521-a9f4-477b-afec-671b2e4ae787 Report Status: 4 Hashed bucket: 100104036028797018963968449Windows Error ReportingApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4356.104204036028797018963968448MsiInstallerApplicationhv-osbrick-7667S-1-5-1812/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1110 Faulting application start time: 0x01d6d08fbd60f323 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: b8a39521-a9f4-477b-afec-671b2e4ae787 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968447Application ErrorApplicationhv-osbrick-766712/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0.103304036028797018963968446MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully.1170704036028797018963968445MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 2:04:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?12T14:04:38.738430700Z.100000400-9223372036854775808444Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application24085108hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 2:04:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4356.104004036028797018963968443MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 2:04:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.409700400-9187343239835811840442Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401732hv-osbrick-766712/12/2020 2:04:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root list with effective date: ?Monday, ?October ?12, ?2020 9:49:04 PM.411100400-9187343239835811840441Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>.410900400-9187343239835811840440Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>.410900400-9187343239835811840439Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>.410900400-9187343239835811840438Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.410900400-9187343239835811840437Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.410900400-9187343239835811840436Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>.410900400-9187343239835811840435Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.410900400-9187343239835811840434Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404444hv-osbrick-766712/12/2020 1:59:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808433Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application30842760hv-osbrick-7667S-1-5-1812/12/2020 1:53:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?12T13:52:46.077269900Z.100010400-9223372036854775808432Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application29842264hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4744.104204036028797018963968431MsiInstallerApplicationhv-osbrick-7667S-1-5-1812/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968430MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968429MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?12T13:52:46.077269900Z.100000400-9223372036854775808428Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application29843884hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?12T13:52:45.552813200Z.100010400-9223372036854775808427Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application29842264hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?12T13:52:45.552813200Z.100000400-9223372036854775808426Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application29843388hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4744.104004036028797018963968425MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4744.104204036028797018963968424MsiInstallerApplicationhv-osbrick-7667S-1-5-1812/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968423MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968422MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4744.104004036028797018963968421MsiInstallerApplicationhv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0.103504036028797018963968420MsiInstallerApplicationhv-osbrick-7667S-1-5-1812/12/2020 1:52:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?12T13:52:02.482179500Z.100000400-9223372036854775808419Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application21122344hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?12T13:52:02.453541400Z.100000400-9223372036854775808418Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application21122344hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100112/12/2020 1:52:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968417Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:51:26 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-13T13:50:26Z. Reason: TBL.1638401638440036028797018963968416Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:51:26 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.409700400-9187343239835811840415Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401712hv-osbrick-766712/12/2020 1:51:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent819704915240036028797018963968414Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/06/10:13:50:56;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968413Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968412Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259200 minutes.103703276840036028797018963968411Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968410Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968409Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
These policies are being excluded since they are only defined with override-only attribute. Policy Names=(Security-SPP-Reserved-EnableNotificationMode) App Id=55c92734-d682-4d71-983e-d6ec3f16059f Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4103301638440036028797018963968408Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100103401638440036028797018963968407Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Validity period has been started. Validity minutes=259200 Grace type=9.103601638440036028797018963968406Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MSA client has been successfully triggered to update the Device License1231101638440036028797018963968405Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f}1230401638440036028797018963968404Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f1230501638440036028797018963968403Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection ended. 2048904915240036028797018963968402Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968401Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check passed. 2048204915240036028797018963968400Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check initiated. 2048104915240036028797018963968399Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection started. 2048804915240036028797018963968398Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS. 106703276840036028797018963968397Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE} License Id=35f0af86-62c5-4fee-bfbb-132c153f56b5100401638440036028797018963968396Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC} License Id=63002446-c91d-4777-bc69-feb47d6ba5bd100401638440036028797018963968395Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Acquisition of End User License was successful. Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4101301638400036028797018963968394Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.409700400-9187343239835811840393Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401732hv-osbrick-766712/12/2020 1:50:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2020/12/22:13:46:45;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968392Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:50:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968391Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00hv-osbrick-766712/12/2020 1:49:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968390cloudbase-initApplicationhv-osbrick-766712/12/2020 1:48:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968389Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:48:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied. . 15340300-9223372036854775808388Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5562036hv-osbrick-7667S-1-5-21-2807356716-2750461230-2573257737-100012/12/2020 1:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7667\Admin' in response to user profile creation. Error code 0x80070005. Access is denied. .604915220036028797018963968387Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00hv-osbrick-766712/12/2020 1:48:06 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.409700400-9187343239835811840386Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13402044hv-osbrick-766712/12/2020 1:47:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968385cloudbase-initApplicationhv-osbrick-766712/12/2020 1:47:26 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7667\cloudbase-init' . 501638440036028797018963968384Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00hv-osbrick-766712/12/2020 1:47:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808383Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5561704hv-osbrick-7667S-1-5-1812/12/2020 1:47:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808382Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5561284hv-osbrick-7667S-1-5-1812/12/2020 1:47:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Delete for component {D63AA156-D534-4BAC-9BF1-55359CF5EC30} failed, error code is The system cannot find the path specified. . 15340300-9223372036854775808381Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application556792hv-osbrick-7667S-1-5-1812/12/2020 1:47:19 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968380Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:47:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968379Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:47:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Proof of Purchase installed successfully. ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845101601638440036028797018963968378Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-766712/12/2020 1:47:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog.462501638440036028797018963968377Microsoft-Windows-EventSystem899daace-4868-4295-afcd-9eb8fb497561Application00hv-osbrick-766712/12/2020 1:47:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808376Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5561668hv-osbrick-7667S-1-5-1812/12/2020 1:47:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808375Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5281472WIN-5T344G8GM1HS-1-5-1812/12/2020 1:46:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968374Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H12/12/2020 1:46:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Name: Microsoft Hyper-V VSS Writer821204036028797018963968373VSSApplicationWIN-5T344G8GM1H12/12/2020 1:46:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of disallowed certificate list with effective date: ?Tuesday, ?September ?15, ?2020 5:56:35 PM.411200400-9187343239835811840372Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication17001804WIN-5T344G8GM1H12/12/2020 1:46:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808371Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5288WIN-5T344G8GM1HS-1-5-1812/12/2020 1:45:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808370Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5281560WIN-5T344G8GM1HS-1-5-1812/12/2020 1:45:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808369Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5281472WIN-5T344G8GM1HS-1-5-1812/12/2020 1:45:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} Writer Name: Shadow Copy Optimization Writer821204036028797018963968368VSSApplicationWIN-5T344G8GM1H12/12/2020 1:45:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4} Writer Name: ASR Writer821204036028797018963968367VSSApplicationWIN-5T344G8GM1H12/12/2020 1:45:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f} Writer Name: COM+ REGDB Writer821204036028797018963968366VSSApplicationWIN-5T344G8GM1H12/12/2020 1:45:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485} Writer Name: Registry Writer821204036028797018963968365VSSApplicationWIN-5T344G8GM1H12/12/2020 1:45:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808364Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9761228WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:13 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required. DETAIL - 9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500: Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security 15300400-9223372036854775808363Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9763432WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The winlogon notification subscriber <SessionEnv> failed a notification event.600103276830036028797018963968362Microsoft-Windows-Winlogondbe9b383-7cf3-4331-91cc-a3cb16a3b538Application00WIN-5T344G8GM1H1/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968361Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448823001638440036028797018963968360Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )] 100301638440036028797018963968359Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining.1230601638440036028797018963968358Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968357Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968356Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Grace period has been started. Grace days=10 Grace type=6.102501638440036028797018963968355Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968354Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The hardware has changed.102403276840036028797018963968353Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Hardware has changed from previous boot. AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4.104001638440036028797018963968352Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968351Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=Sysprep.exe90001638440036028797018963968350Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968349Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00WIN-5T344G8GM1H1/19/2018 9:47:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]