MessageIdVersionQualifiersLevelTaskOpcodeKeywordsRecordIdProviderNameProviderIdLogNameProcessIdThreadIdMachineNameUserIdTimeCreatedActivityIdRelatedActivityIdContainerLogMatchedQueryIdsBookmarkLevelDisplayNameOpcodeDisplayNameTaskDisplayNameKeywordsDisplayNamesProperties
004036028797018963968626neutron-ovs-agentApplicationhv-osbrick-763712/15/2020 3:00:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968625cinder-volumeApplicationhv-osbrick-763712/15/2020 3:00:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968624nova-computeApplicationhv-osbrick-763712/15/2020 3:00:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968623Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-16T14:46:32Z. Reason: TBL.1638401638440036028797018963968622Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968621Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259174 minutes.103703276840036028797018963968620Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968619Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968618Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968617Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:47:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808616Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application44482928hv-osbrick-7637S-1-5-1812/15/2020 2:45:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c754 Analysis symbol: Rechecking for solution: 0 Report Id: 42d585e1-2f07-4f2e-84c8-430ab1c0d9f6 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968615Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c679 Analysis symbol: Rechecking for solution: 0 Report Id: 9b9daafc-5ce0-4e0f-8e68-6ef5c347122a Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968614Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c5ae Analysis symbol: Rechecking for solution: 0 Report Id: 1e54f46b-0608-4325-95e1-646d59d516b6 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968613Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c4f3 Analysis symbol: Rechecking for solution: 0 Report Id: 13beb8a1-1605-4c84-b998-a769dafa8415 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968612Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c408 Analysis symbol: Rechecking for solution: 0 Report Id: 5874e62a-622b-4c4a-9306-089a952cba08 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968611Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c32e Analysis symbol: Rechecking for solution: 0 Report Id: d8350901-1f9c-47f9-9f61-bfdd05b416e3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968610Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c263 Analysis symbol: Rechecking for solution: 0 Report Id: 6574195f-708e-45ea-87be-5ba3f03ca139 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968609Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c188 Analysis symbol: Rechecking for solution: 0 Report Id: 440049ec-2216-4ef4-bdd9-7a2a7e7fe12d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968608Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bb5c0dc Analysis symbol: Rechecking for solution: 0 Report Id: 7905199c-42c7-4df7-8e5d-05801f50bd8e Report Status: 4 Hashed bucket: 100104036028797018963968607Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91c0bd Analysis symbol: Rechecking for solution: 0 Report Id: 32375494-c40f-4572-8db7-6840a793ad2e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968606Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11f0 Faulting application start time: 0x01d6d2ef9bc88aae Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7905199c-42c7-4df7-8e5d-05801f50bd8e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968605Application ErrorApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f7dc05f Analysis symbol: Rechecking for solution: 0 Report Id: df81efed-5aa4-4ea4-8fae-05d4cb4dbc6b Report Status: 4 Hashed bucket: 100104036028797018963968604Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x7e4 Faulting application start time: 0x01d6d2ef9bb4c12a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: df81efed-5aa4-4ea4-8fae-05d4cb4dbc6b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968603Application ErrorApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91bff2 Analysis symbol: Rechecking for solution: 0 Report Id: ec3e6438-19df-4a9f-8675-cf9cc20beea1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968602Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_106dbfd2 Analysis symbol: Rechecking for solution: 0 Report Id: 77e7c287-93e0-4cf1-b059-6da2848904fb Report Status: 4 Hashed bucket: 100104036028797018963968601Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13b8 Faulting application start time: 0x01d6d2ef9ba0d3a8 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 77e7c287-93e0-4cf1-b059-6da2848904fb Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968600Application ErrorApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0fb9bf55 Analysis symbol: Rechecking for solution: 0 Report Id: bf4ceace-21e8-4455-9bf1-65692c8af96f Report Status: 4 Hashed bucket: 100104036028797018963968599Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91bf17 Analysis symbol: Rechecking for solution: 0 Report Id: 57fa3040-1191-4a65-9c7a-d3973c107489 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968598Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xd8 Faulting application start time: 0x01d6d2ef9b8b5f8f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: bf4ceace-21e8-4455-9bf1-65692c8af96f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968597Application ErrorApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10b5beb9 Analysis symbol: Rechecking for solution: 0 Report Id: b39b1984-2caf-460a-9d11-268dd1359442 Report Status: 4 Hashed bucket: 100104036028797018963968596Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf58 Faulting application start time: 0x01d6d2ef9b73208d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: b39b1984-2caf-460a-9d11-268dd1359442 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968595Application ErrorApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91be4c Analysis symbol: Rechecking for solution: 0 Report Id: db596008-312e-4d3f-bf5c-6020384743d3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968594Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ef9be2c Analysis symbol: Rechecking for solution: 0 Report Id: 601b4930-1662-40d7-8e7a-859a3317cb4e Report Status: 4 Hashed bucket: 100104036028797018963968593Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1358 Faulting application start time: 0x01d6d2ef9b5fa404 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 601b4930-1662-40d7-8e7a-859a3317cb4e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968592Application ErrorApplicationhv-osbrick-763712/15/2020 2:36:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12f9bdaf Analysis symbol: Rechecking for solution: 0 Report Id: 805971c4-262d-4a5a-8d8e-fb518beb3a86 Report Status: 4 Hashed bucket: 100104036028797018963968591Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91bd61 Analysis symbol: Rechecking for solution: 0 Report Id: d9b5289d-2702-43fc-86c4-093bc7494220 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968590Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x180 Faulting application start time: 0x01d6d2ef9b4b6ac2 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 805971c4-262d-4a5a-8d8e-fb518beb3a86 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968589Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11a1bd23 Analysis symbol: Rechecking for solution: 0 Report Id: 0fc4ee0c-825d-4536-ad56-f45e83f91437 Report Status: 4 Hashed bucket: 100104036028797018963968588Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe48 Faulting application start time: 0x01d6d2ef9b380131 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0fc4ee0c-825d-4536-ad56-f45e83f91437 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968587Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91bc96 Analysis symbol: Rechecking for solution: 0 Report Id: 9e5f8ae3-e237-4b77-8f15-f9976f35fc1e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968586Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04e9bc96 Analysis symbol: Rechecking for solution: 0 Report Id: 0bc0308e-27e5-41db-9605-013cab37e9d1 Report Status: 4 Hashed bucket: 100104036028797018963968585Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x514 Faulting application start time: 0x01d6d2ef9b20bd7f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0bc0308e-27e5-41db-9605-013cab37e9d1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968584Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1141bc0a Analysis symbol: Rechecking for solution: 0 Report Id: a6acbfcc-3ed9-47bc-afe1-b1478825bedf Report Status: 4 Hashed bucket: 100104036028797018963968583Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91bbbb Analysis symbol: Rechecking for solution: 0 Report Id: f9775d3f-8d7f-47ad-b8ff-4417e75bdf91 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968582Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13ac Faulting application start time: 0x01d6d2ef9b0d15e9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a6acbfcc-3ed9-47bc-afe1-b1478825bedf Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968581Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_107dbb8d Analysis symbol: Rechecking for solution: 0 Report Id: a060b7d2-7266-4840-99fa-d954687ef893 Report Status: 4 Hashed bucket: 100104036028797018963968580Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12d8 Faulting application start time: 0x01d6d2ef9af82e93 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a060b7d2-7266-4840-99fa-d954687ef893 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968579Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04f5bb10 Analysis symbol: Rechecking for solution: 0 Report Id: ca54965b-e7f5-4ef9-b461-b11c985a27bb Report Status: 4 Hashed bucket: 100104036028797018963968578Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91baf0 Analysis symbol: Rechecking for solution: 0 Report Id: 617b5d88-9a61-4cd7-93cc-80923e9e4335 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968577Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x77c Faulting application start time: 0x01d6d2ef9ae48c44 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ca54965b-e7f5-4ef9-b461-b11c985a27bb Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968576Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124dba83 Analysis symbol: Rechecking for solution: 0 Report Id: bd9d184e-9c9f-4ab5-8b9d-17f1ac6ad511 Report Status: 4 Hashed bucket: 100104036028797018963968575Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x52c Faulting application start time: 0x01d6d2ef9ad0285e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: bd9d184e-9c9f-4ab5-8b9d-17f1ac6ad511 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968574Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91ba06 Analysis symbol: Rechecking for solution: 0 Report Id: 6bc21a24-878b-43df-89e0-cb64f5e43b91 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968573Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10bdb9f6 Analysis symbol: Rechecking for solution: 0 Report Id: 8f24a87c-70c5-43f2-b961-ae6e56938e02 Report Status: 4 Hashed bucket: 100104036028797018963968572Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10b4 Faulting application start time: 0x01d6d2ef9abbf261 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 8f24a87c-70c5-43f2-b961-ae6e56938e02 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968571Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d45b96a Analysis symbol: Rechecking for solution: 0 Report Id: a10806f5-3b07-4d6e-8c76-905a7975cee1 Report Status: 4 Hashed bucket: 100104036028797018963968570Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91b93b Analysis symbol: Rechecking for solution: 0 Report Id: d88d8f8e-bf2b-4013-b271-13e96362cd5a Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968569Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x81c Faulting application start time: 0x01d6d2ef9aa681df Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a10806f5-3b07-4d6e-8c76-905a7975cee1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968568Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02a1b8dd Analysis symbol: Rechecking for solution: 0 Report Id: 16458488-8fd7-4d15-92ea-3da37fb1c51a Report Status: 4 Hashed bucket: 100104036028797018963968567Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1fc Faulting application start time: 0x01d6d2ef9a910893 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 16458488-8fd7-4d15-92ea-3da37fb1c51a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968566Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91b860 Analysis symbol: Rechecking for solution: 0 Report Id: 23c5bc4f-e6ac-48d8-a1fd-f0649f367763 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968565Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_084db860 Analysis symbol: Rechecking for solution: 0 Report Id: bf81c3b1-2e7b-459e-9fdf-e0103bda5500 Report Status: 4 Hashed bucket: 100104036028797018963968564Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1288 Faulting application start time: 0x01d6d2ef9a7b378e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: bf81c3b1-2e7b-459e-9fdf-e0103bda5500 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968563Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_09fdb7e3 Analysis symbol: Rechecking for solution: 0 Report Id: 2aa8f8a6-cbba-4aa1-9ce4-aa645267e3e3 Report Status: 4 Hashed bucket: 100104036028797018963968562Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91b7a5 Analysis symbol: Rechecking for solution: 0 Report Id: 4cfd837b-5a42-462a-84b0-1233dc967afa Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968561Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x2e8 Faulting application start time: 0x01d6d2ef9a6790ad Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2aa8f8a6-cbba-4aa1-9ce4-aa645267e3e3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968560Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0201b756 Analysis symbol: Rechecking for solution: 0 Report Id: e76deda0-e8c6-443d-9561-e477c65c11af Report Status: 4 Hashed bucket: 100104036028797018963968559Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1380 Faulting application start time: 0x01d6d2ef9a52670d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e76deda0-e8c6-443d-9561-e477c65c11af Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968558Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91b6ca Analysis symbol: Rechecking for solution: 0 Report Id: fb467d53-e818-42e9-a181-9d688f09db8e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968557Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325b6ca Analysis symbol: Rechecking for solution: 0 Report Id: 3c047428-115f-4626-8841-19e6fc434224 Report Status: 4 Hashed bucket: 100104036028797018963968556Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1284 Faulting application start time: 0x01d6d2ef9a3d52ba Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 3c047428-115f-4626-8841-19e6fc434224 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968555Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10e9b64d Analysis symbol: Rechecking for solution: 0 Report Id: b9cdbe64-42f8-4377-bb61-96c915f248f8 Report Status: 4 Hashed bucket: 100104036028797018963968554Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe30 Faulting application start time: 0x01d6d2ef9a29cc92 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: b9cdbe64-42f8-4377-bb61-96c915f248f8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968553Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91b5ef Analysis symbol: Rechecking for solution: 0 Report Id: 21fe1de9-2794-415d-b45c-933a3325526e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968552Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bc5b5c0 Analysis symbol: Rechecking for solution: 0 Report Id: 508bceb9-4896-460e-a9b6-d1fd6229e5d6 Report Status: 4 Hashed bucket: 100104036028797018963968551Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x484 Faulting application start time: 0x01d6d2ef9a167500 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 508bceb9-4896-460e-a9b6-d1fd6229e5d6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968550Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0331b543 Analysis symbol: Rechecking for solution: 0 Report Id: 939769df-f8da-4bee-b4a4-6dabafc18923 Report Status: 4 Hashed bucket: 100104036028797018963968549Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c91b514 Analysis symbol: Rechecking for solution: 0 Report Id: a17110df-246d-415b-9be2-3a09b8911906 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968548Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf6c Faulting application start time: 0x01d6d2ef9a035f81 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 939769df-f8da-4bee-b4a4-6dabafc18923 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968547Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1195b4c6 Analysis symbol: Rechecking for solution: 0 Report Id: f304f96f-e980-4274-8737-74f5425b7798 Report Status: 4 Hashed bucket: 100104036028797018963968546Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1190 Faulting application start time: 0x01d6d2ef99f1764f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f304f96f-e980-4274-8737-74f5425b7798 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968545Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e55b449 Analysis symbol: Rechecking for solution: 0 Report Id: 2b2762db-2653-4209-8fb1-b5d34c253060 Report Status: 4 Hashed bucket: 100104036028797018963968544Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10d0 Faulting application start time: 0x01d6d2ef99dfbcf6 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2b2762db-2653-4209-8fb1-b5d34c253060 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968543Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f9db3cc Analysis symbol: Rechecking for solution: 0 Report Id: 24cf7909-2d8f-460f-bc33-6a583ceb4b17 Report Status: 4 Hashed bucket: 100104036028797018963968542Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x448 Faulting application start time: 0x01d6d2ef99cb216a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 24cf7909-2d8f-460f-bc33-6a583ceb4b17 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968541Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b6db34f Analysis symbol: Rechecking for solution: 0 Report Id: 336860d9-76e0-47e5-85a7-f31dc09970f6 Report Status: 4 Hashed bucket: 100104036028797018963968540Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1124 Faulting application start time: 0x01d6d2ef99b5b654 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 336860d9-76e0-47e5-85a7-f31dc09970f6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968539Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_135db2a3 Analysis symbol: Rechecking for solution: 0 Report Id: 8757cff4-d6e0-4cf2-84f6-fcfc588cb007 Report Status: 4 Hashed bucket: 100104036028797018963968538Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13dc Faulting application start time: 0x01d6d2ef999dd323 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 8757cff4-d6e0-4cf2-84f6-fcfc588cb007 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968537Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b71b236 Analysis symbol: Rechecking for solution: 0 Report Id: 42d585e1-2f07-4f2e-84c8-430ab1c0d9f6 Report Status: 4 Hashed bucket: 100104036028797018963968536Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89b1f7 Analysis symbol: Rechecking for solution: 0 Report Id: 676ca64e-5581-48f5-9246-c7554d556ffd Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968535Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x127c Faulting application start time: 0x01d6d2ef998876a0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 42d585e1-2f07-4f2e-84c8-430ab1c0d9f6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968534Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_057db18a Analysis symbol: Rechecking for solution: 0 Report Id: 9b9daafc-5ce0-4e0f-8e68-6ef5c347122a Report Status: 4 Hashed bucket: 100104036028797018963968533Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x20 Faulting application start time: 0x01d6d2ef9972ae9e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9b9daafc-5ce0-4e0f-8e68-6ef5c347122a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968532Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89b11d Analysis symbol: Rechecking for solution: 0 Report Id: 7b8fb1fc-f6e4-46a0-a678-92ba71b2cb26 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968531Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1125b11d Analysis symbol: Rechecking for solution: 0 Report Id: 1e54f46b-0608-4325-95e1-646d59d516b6 Report Status: 4 Hashed bucket: 100104036028797018963968530Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10ac Faulting application start time: 0x01d6d2ef995da8d9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1e54f46b-0608-4325-95e1-646d59d516b6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968529Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_100db061 Analysis symbol: Rechecking for solution: 0 Report Id: 13beb8a1-1605-4c84-b998-a769dafa8415 Report Status: 4 Hashed bucket: 100104036028797018963968528Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89b042 Analysis symbol: Rechecking for solution: 0 Report Id: 9cd2b3f2-9cad-421b-a1f4-5a24d2c2d86d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968527Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xd54 Faulting application start time: 0x01d6d2ef99459e5c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 13beb8a1-1605-4c84-b998-a769dafa8415 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968526Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0501afe4 Analysis symbol: Rechecking for solution: 0 Report Id: 5874e62a-622b-4c4a-9306-089a952cba08 Report Status: 4 Hashed bucket: 100104036028797018963968525Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1030 Faulting application start time: 0x01d6d2ef993024e5 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5874e62a-622b-4c4a-9306-089a952cba08 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968524Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89af67 Analysis symbol: Rechecking for solution: 0 Report Id: 8105aed4-d692-4f98-9a16-8b75e04e0b27 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968523Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bb9af48 Analysis symbol: Rechecking for solution: 0 Report Id: d8350901-1f9c-47f9-9f61-bfdd05b416e3 Report Status: 4 Hashed bucket: 100104036028797018963968522Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x8ec Faulting application start time: 0x01d6d2ef991a2f96 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d8350901-1f9c-47f9-9f61-bfdd05b416e3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968521Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0591aecb Analysis symbol: Rechecking for solution: 0 Report Id: 6574195f-708e-45ea-87be-5ba3f03ca139 Report Status: 4 Hashed bucket: 100104036028797018963968520Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89aeac Analysis symbol: Rechecking for solution: 0 Report Id: c43eede9-465d-4ea5-8d04-df52c2e118e3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968519Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x888 Faulting application start time: 0x01d6d2ef9905e7ab Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6574195f-708e-45ea-87be-5ba3f03ca139 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968518Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1291ae3e Analysis symbol: Rechecking for solution: 0 Report Id: 440049ec-2216-4ef4-bdd9-7a2a7e7fe12d Report Status: 4 Hashed bucket: 100104036028797018963968517Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc54 Faulting application start time: 0x01d6d2ef98efebf1 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 440049ec-2216-4ef4-bdd9-7a2a7e7fe12d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968516Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89adb2 Analysis symbol: Rechecking for solution: 0 Report Id: cfe38fef-fee5-4eec-8e3a-f024d608b8e6 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968515Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10fdadb2 Analysis symbol: Rechecking for solution: 0 Report Id: 32375494-c40f-4572-8db7-6840a793ad2e Report Status: 4 Hashed bucket: 100104036028797018963968514Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe04 Faulting application start time: 0x01d6d2ef98da033c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 32375494-c40f-4572-8db7-6840a793ad2e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968513Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ed1ad25 Analysis symbol: Rechecking for solution: 0 Report Id: ec3e6438-19df-4a9f-8675-cf9cc20beea1 Report Status: 4 Hashed bucket: 100104036028797018963968512Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89ace7 Analysis symbol: Rechecking for solution: 0 Report Id: e8979af1-0d8d-4678-b70a-c6dbf98b4129 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968511Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1284 Faulting application start time: 0x01d6d2ef98c505b9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ec3e6438-19df-4a9f-8675-cf9cc20beea1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968510Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1155ac89 Analysis symbol: Rechecking for solution: 0 Report Id: 57fa3040-1191-4a65-9c7a-d3973c107489 Report Status: 4 Hashed bucket: 100104036028797018963968509Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe30 Faulting application start time: 0x01d6d2ef98acfc43 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 57fa3040-1191-4a65-9c7a-d3973c107489 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968508Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89ac0c Analysis symbol: Rechecking for solution: 0 Report Id: 0005dfa4-f169-4de1-af37-05e5e975c0b1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968507Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f89abfc Analysis symbol: Rechecking for solution: 0 Report Id: db596008-312e-4d3f-bf5c-6020384743d3 Report Status: 4 Hashed bucket: 100104036028797018963968506Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12b4 Faulting application start time: 0x01d6d2ef9895a8eb Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: db596008-312e-4d3f-bf5c-6020384743d3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968505Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0869ab60 Analysis symbol: Rechecking for solution: 0 Report Id: d9b5289d-2702-43fc-86c4-093bc7494220 Report Status: 4 Hashed bucket: 100104036028797018963968504Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89ab50 Analysis symbol: Rechecking for solution: 0 Report Id: acc0f000-259b-469c-b7ac-f9e8ecf14ab0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968503Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1188 Faulting application start time: 0x01d6d2ef9881055d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d9b5289d-2702-43fc-86c4-093bc7494220 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968502Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_106daad3 Analysis symbol: Rechecking for solution: 0 Report Id: 9e5f8ae3-e237-4b77-8f15-f9976f35fc1e Report Status: 4 Hashed bucket: 100104036028797018963968501Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1178 Faulting application start time: 0x01d6d2ef986cda7a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9e5f8ae3-e237-4b77-8f15-f9976f35fc1e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968500Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89aa47 Analysis symbol: Rechecking for solution: 0 Report Id: e60c14e7-73a8-4813-8e27-e77435aab02d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968499Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1185aa37 Analysis symbol: Rechecking for solution: 0 Report Id: f9775d3f-8d7f-47ad-b8ff-4417e75bdf91 Report Status: 4 Hashed bucket: 100104036028797018963968498Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1120 Faulting application start time: 0x01d6d2ef9852c92f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f9775d3f-8d7f-47ad-b8ff-4417e75bdf91 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968497Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1335a9aa Analysis symbol: Rechecking for solution: 0 Report Id: 617b5d88-9a61-4cd7-93cc-80923e9e4335 Report Status: 4 Hashed bucket: 100104036028797018963968496Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89a98b Analysis symbol: Rechecking for solution: 0 Report Id: 757169aa-bd25-4354-a4ae-bacc0992a6ce Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968495Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x62c Faulting application start time: 0x01d6d2ef983d344e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 617b5d88-9a61-4cd7-93cc-80923e9e4335 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968494Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10b1a91e Analysis symbol: Rechecking for solution: 0 Report Id: 6bc21a24-878b-43df-89e0-cb64f5e43b91 Report Status: 4 Hashed bucket: 100104036028797018963968493Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13b8 Faulting application start time: 0x01d6d2ef9828ac5d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6bc21a24-878b-43df-89e0-cb64f5e43b91 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968492Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89a8b0 Analysis symbol: Rechecking for solution: 0 Report Id: 82dccdca-b3e3-493d-9474-befa88d72dfa Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968491Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0249a8a1 Analysis symbol: Rechecking for solution: 0 Report Id: d88d8f8e-bf2b-4013-b271-13e96362cd5a Report Status: 4 Hashed bucket: 100104036028797018963968490Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xfa0 Faulting application start time: 0x01d6d2ef9813e084 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d88d8f8e-bf2b-4013-b271-13e96362cd5a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968489Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ef5a814 Analysis symbol: Rechecking for solution: 0 Report Id: 23c5bc4f-e6ac-48d8-a1fd-f0649f367763 Report Status: 4 Hashed bucket: 100104036028797018963968488Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e89a7d6 Analysis symbol: Rechecking for solution: 0 Report Id: 74afae8f-199a-426a-a52b-3145dd6eb398 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968487Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10a4 Faulting application start time: 0x01d6d2ef97ff0040 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 23c5bc4f-e6ac-48d8-a1fd-f0649f367763 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968486Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13b1a778 Analysis symbol: Rechecking for solution: 0 Report Id: 4cfd837b-5a42-462a-84b0-1233dc967afa Report Status: 4 Hashed bucket: 100104036028797018963968485Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12b8 Faulting application start time: 0x01d6d2ef97e742f2 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 4cfd837b-5a42-462a-84b0-1233dc967afa Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968484Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e1da6dc Analysis symbol: Rechecking for solution: 0 Report Id: fb467d53-e818-42e9-a181-9d688f09db8e Report Status: 4 Hashed bucket: 100104036028797018963968483Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1200 Faulting application start time: 0x01d6d2ef97cfe630 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: fb467d53-e818-42e9-a181-9d688f09db8e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968482Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124da64f Analysis symbol: Rechecking for solution: 0 Report Id: 21fe1de9-2794-415d-b45c-933a3325526e Report Status: 4 Hashed bucket: 100104036028797018963968481Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc80 Faulting application start time: 0x01d6d2ef97b66aff Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 21fe1de9-2794-415d-b45c-933a3325526e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968480Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05dda5a3 Analysis symbol: Rechecking for solution: 0 Report Id: a17110df-246d-415b-9be2-3a09b8911906 Report Status: 4 Hashed bucket: 100104036028797018963968479Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x478 Faulting application start time: 0x01d6d2ef97a0d8bb Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a17110df-246d-415b-9be2-3a09b8911906 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968478Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0421a517 Analysis symbol: Rechecking for solution: 0 Report Id: 676ca64e-5581-48f5-9246-c7554d556ffd Report Status: 4 Hashed bucket: 100104036028797018963968477Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11b8 Faulting application start time: 0x01d6d2ef9788af22 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 676ca64e-5581-48f5-9246-c7554d556ffd Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968476Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13e1a4b9 Analysis symbol: Rechecking for solution: 0 Report Id: 0558b66a-4185-4994-b836-c052773fc72f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968475Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0deda48a Analysis symbol: Rechecking for solution: 0 Report Id: 7b8fb1fc-f6e4-46a0-a678-92ba71b2cb26 Report Status: 4 Hashed bucket: 100104036028797018963968474Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1314 Faulting application start time: 0x01d6d2ef9772453c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7b8fb1fc-f6e4-46a0-a678-92ba71b2cb26 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968473Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1359a3ee Analysis symbol: Rechecking for solution: 0 Report Id: 9cd2b3f2-9cad-421b-a1f4-5a24d2c2d86d Report Status: 4 Hashed bucket: 100104036028797018963968472Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x85c Faulting application start time: 0x01d6d2ef975be5de Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9cd2b3f2-9cad-421b-a1f4-5a24d2c2d86d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968471Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_038da351 Analysis symbol: Rechecking for solution: 0 Report Id: 8105aed4-d692-4f98-9a16-8b75e04e0b27 Report Status: 4 Hashed bucket: 100104036028797018963968470Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf60 Faulting application start time: 0x01d6d2ef97452d84 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 8105aed4-d692-4f98-9a16-8b75e04e0b27 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968469Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03c5a2b5 Analysis symbol: Rechecking for solution: 0 Report Id: c43eede9-465d-4ea5-8d04-df52c2e118e3 Report Status: 4 Hashed bucket: 100104036028797018963968468Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xac4 Faulting application start time: 0x01d6d2ef972c620c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c43eede9-465d-4ea5-8d04-df52c2e118e3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968467Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1061a219 Analysis symbol: Rechecking for solution: 0 Report Id: cfe38fef-fee5-4eec-8e3a-f024d608b8e6 Report Status: 4 Hashed bucket: 100104036028797018963968466Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x9f0 Faulting application start time: 0x01d6d2ef97133954 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: cfe38fef-fee5-4eec-8e3a-f024d608b8e6 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968465Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_043da16d Analysis symbol: Rechecking for solution: 0 Report Id: e8979af1-0d8d-4678-b70a-c6dbf98b4129 Report Status: 4 Hashed bucket: 100104036028797018963968464Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11d8 Faulting application start time: 0x01d6d2ef96f471e0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e8979af1-0d8d-4678-b70a-c6dbf98b4129 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968463Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11e1a0a2 Analysis symbol: Rechecking for solution: 0 Report Id: 0005dfa4-f169-4de1-af37-05e5e975c0b1 Report Status: 4 Hashed bucket: 100104036028797018963968462Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe2c Faulting application start time: 0x01d6d2ef96d7e700 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0005dfa4-f169-4de1-af37-05e5e975c0b1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968461Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?15T14:35:45.870690200Z.100010400-9223372036854775808460Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application41964848hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02199ff6 Analysis symbol: Rechecking for solution: 0 Report Id: acc0f000-259b-469c-b7ac-f9e8ecf14ab0 Report Status: 4 Hashed bucket: 100104036028797018963968459Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x530 Faulting application start time: 0x01d6d2ef96c0ade4 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: acc0f000-259b-469c-b7ac-f9e8ecf14ab0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968458Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12a59f69 Analysis symbol: Rechecking for solution: 0 Report Id: e60c14e7-73a8-4813-8e27-e77435aab02d Report Status: 4 Hashed bucket: 100104036028797018963968457Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x108c Faulting application start time: 0x01d6d2ef96a92153 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e60c14e7-73a8-4813-8e27-e77435aab02d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968456Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12ed9eae Analysis symbol: Rechecking for solution: 0 Report Id: 757169aa-bd25-4354-a4ae-bacc0992a6ce Report Status: 4 Hashed bucket: 100104036028797018963968455Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x878 Faulting application start time: 0x01d6d2ef969396af Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 757169aa-bd25-4354-a4ae-bacc0992a6ce Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968454Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d959e21 Analysis symbol: Rechecking for solution: 0 Report Id: 82dccdca-b3e3-493d-9474-befa88d72dfa Report Status: 4 Hashed bucket: 100104036028797018963968453Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x107c Faulting application start time: 0x01d6d2ef967ab460 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 82dccdca-b3e3-493d-9474-befa88d72dfa Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968452Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f219d95 Analysis symbol: Rechecking for solution: 0 Report Id: 74afae8f-199a-426a-a52b-3145dd6eb398 Report Status: 4 Hashed bucket: 100104036028797018963968451Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x574 Faulting application start time: 0x01d6d2ef96615107 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 74afae8f-199a-426a-a52b-3145dd6eb398 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968450Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ce59cd9 Analysis symbol: Rechecking for solution: 0 Report Id: 0558b66a-4185-4994-b836-c052773fc72f Report Status: 4 Hashed bucket: 100104036028797018963968449Windows Error ReportingApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 2028.104204036028797018963968448MsiInstallerApplicationhv-osbrick-7637S-1-5-1812/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0.103304036028797018963968447MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully.1170704036028797018963968446MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1128 Faulting application start time: 0x01d6d2ef960a1122 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0558b66a-4185-4994-b836-c052773fc72f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968445Application ErrorApplicationhv-osbrick-763712/15/2020 2:35:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?15T14:35:45.870690200Z.100000400-9223372036854775808444Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application41964388hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root list with effective date: ?Monday, ?October ?12, ?2020 9:49:04 PM.411100400-9187343239835811840443Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>.410900400-9187343239835811840442Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.410900400-9187343239835811840441Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>.410900400-9187343239835811840440Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>.410900400-9187343239835811840439Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.410900400-9187343239835811840438Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.410900400-9187343239835811840437Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>.410900400-9187343239835811840436Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.410900400-9187343239835811840435Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401768hv-osbrick-763712/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 2028.104004036028797018963968434MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:35:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.409700400-9187343239835811840433Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401352hv-osbrick-763712/15/2020 2:35:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808432Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application50285032hv-osbrick-7637S-1-5-1812/15/2020 2:23:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?15T14:23:21.751708900Z.100010400-9223372036854775808431Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47323360hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4152.104204036028797018963968430MsiInstallerApplicationhv-osbrick-7637S-1-5-1812/15/2020 2:23:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968429MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968428MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?15T14:23:21.751708900Z.100000400-9223372036854775808427Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47323744hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?15T14:23:21.179832200Z.100010400-9223372036854775808426Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47323360hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?15T14:23:21.179832200Z.100000400-9223372036854775808425Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application47324984hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4152.104004036028797018963968424MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4152.104204036028797018963968423MsiInstallerApplicationhv-osbrick-7637S-1-5-1812/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968422MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968421MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4152.104004036028797018963968420MsiInstallerApplicationhv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:23:20 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0.103504036028797018963968419MsiInstallerApplicationhv-osbrick-7637S-1-5-1812/15/2020 2:23:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?15T14:22:37.088135100Z.100000400-9223372036854775808418Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application50964984hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:22:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?15T14:22:37.088135100Z.100000400-9223372036854775808417Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application50964984hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100112/15/2020 2:22:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.409700400-9187343239835811840416Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401256hv-osbrick-763712/15/2020 2:22:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968415Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:21:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-16T14:20:04Z. Reason: TBL.1638401638440036028797018963968414Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:21:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent819704915240036028797018963968413Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/06/13:14:20:34;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968412Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968411Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259200 minutes.103703276840036028797018963968410Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968409Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968408Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
These policies are being excluded since they are only defined with override-only attribute. Policy Names=(Security-SPP-Reserved-EnableNotificationMode) App Id=55c92734-d682-4d71-983e-d6ec3f16059f Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4103301638440036028797018963968407Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100103401638440036028797018963968406Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Validity period has been started. Validity minutes=259200 Grace type=9.103601638440036028797018963968405Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MSA client has been successfully triggered to update the Device License1231101638440036028797018963968404Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f}1230401638440036028797018963968403Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f1230501638440036028797018963968402Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection ended. 2048904915240036028797018963968401Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968400Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check passed. 2048204915240036028797018963968399Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check initiated. 2048104915240036028797018963968398Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection started. 2048804915240036028797018963968397Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS. 106703276840036028797018963968396Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE} License Id=d52a534c-589d-4f86-998f-0db868b32a6e100401638440036028797018963968395Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC} License Id=d9b3bab7-a4c6-4f3f-abe3-9abfa0663989100401638440036028797018963968394Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Acquisition of End User License was successful. Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4101301638400036028797018963968393Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.409700400-9187343239835811840392Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401256hv-osbrick-763712/15/2020 2:20:25 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2020/12/25:14:15:22;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968391Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:20:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968390Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00hv-osbrick-763712/15/2020 2:19:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968389cloudbase-initApplicationhv-osbrick-763712/15/2020 2:17:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968388Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:17:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied. . 15340300-9223372036854775808387Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5962880hv-osbrick-7637S-1-5-21-994327717-2644012531-259568524-100012/15/2020 2:17:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7637\Admin' in response to user profile creation. Error code 0x80070005. Access is denied. .604915220036028797018963968386Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00hv-osbrick-763712/15/2020 2:17:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968385cloudbase-initApplicationhv-osbrick-763712/15/2020 2:17:07 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7637\cloudbase-init' . 501638440036028797018963968384Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00hv-osbrick-763712/15/2020 2:17:05 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.409700400-9187343239835811840383Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401668hv-osbrick-763712/15/2020 2:17:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808382Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5961924hv-osbrick-7637S-1-5-1812/15/2020 2:17:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808381Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5962036hv-osbrick-7637S-1-5-1812/15/2020 2:17:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808380Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5961764hv-osbrick-7637S-1-5-1812/15/2020 2:17:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968379Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:17:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968378Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:17:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Proof of Purchase installed successfully. ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845101601638440036028797018963968377Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00hv-osbrick-763712/15/2020 2:17:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog.462501638440036028797018963968376Microsoft-Windows-EventSystem899daace-4868-4295-afcd-9eb8fb497561Application00hv-osbrick-763712/15/2020 2:17:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808375Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5361476WIN-5T344G8GM1HS-1-5-1812/15/2020 2:16:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The VSS service is shutting down due to shutdown event from the Service Control Manager. 822504036028797018963968374VSSApplicationWIN-5T344G8GM1H12/15/2020 2:16:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Name: Microsoft Hyper-V VSS Writer821204036028797018963968373VSSApplicationWIN-5T344G8GM1H12/15/2020 2:15:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM.411200400-9187343239835811840372Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication16921808WIN-5T344G8GM1H12/15/2020 2:15:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808371Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5361836WIN-5T344G8GM1HS-1-5-1812/15/2020 2:15:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808370Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5361588WIN-5T344G8GM1HS-1-5-1812/15/2020 2:15:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808369Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5361476WIN-5T344G8GM1HS-1-5-1812/15/2020 2:15:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} Writer Name: Shadow Copy Optimization Writer821204036028797018963968368VSSApplicationWIN-5T344G8GM1H12/15/2020 2:15:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4} Writer Name: ASR Writer821204036028797018963968367VSSApplicationWIN-5T344G8GM1H12/15/2020 2:15:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f} Writer Name: COM+ REGDB Writer821204036028797018963968366VSSApplicationWIN-5T344G8GM1H12/15/2020 2:15:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485} Writer Name: Registry Writer821204036028797018963968365VSSApplicationWIN-5T344G8GM1H12/15/2020 2:15:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808364Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9761228WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:13 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required. DETAIL - 9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500: Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security 15300400-9223372036854775808363Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9763432WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The winlogon notification subscriber <SessionEnv> failed a notification event.600103276830036028797018963968362Microsoft-Windows-Winlogondbe9b383-7cf3-4331-91cc-a3cb16a3b538Application00WIN-5T344G8GM1H1/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968361Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448823001638440036028797018963968360Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )] 100301638440036028797018963968359Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining.1230601638440036028797018963968358Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968357Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968356Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Grace period has been started. Grace days=10 Grace type=6.102501638440036028797018963968355Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968354Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The hardware has changed.102403276840036028797018963968353Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Hardware has changed from previous boot. AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4.104001638440036028797018963968352Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968351Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=Sysprep.exe90001638440036028797018963968350Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968349Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00WIN-5T344G8GM1H1/19/2018 9:47:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]