Message | Id | Version | Qualifiers | Level | Task | Opcode | Keywords | RecordId | ProviderName | ProviderId | LogName | ProcessId | ThreadId | MachineName | UserId | TimeCreated | ActivityId | RelatedActivityId | ContainerLog | MatchedQueryIds | Bookmark | LevelDisplayName | OpcodeDisplayName | TaskDisplayName | KeywordsDisplayNames | Properties |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 590 | neutron-ovs-agent | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:28:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 2 | 0 | | 36028797018963968 | 589 | cinder-volume | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:28:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 588 | cinder-volume | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:28:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 587 | nova-compute | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:28:36 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 586 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2020-12-10T10:17:47Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 585 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 584 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:17 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259174 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 583 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:17 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 582 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:17 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 581 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:17 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 580 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 10:18:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 579 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 3004 | 5056 | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 10:16:56 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10248213
Analysis symbol:
Rechecking for solution: 0
Report Id: 45495070-b315-4165-938c-cd9dcfa9b009
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 578 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1024803e
Analysis symbol:
Rechecking for solution: 0
Report Id: b3bbd839-8908-4ddf-9d8b-e525444f6579
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 577 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247f05
Analysis symbol:
Rechecking for solution: 0
Report Id: e4a97a6a-e6cd-4962-b757-5eefc494f32a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 576 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:51 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247ddc
Analysis symbol:
Rechecking for solution: 0
Report Id: 268decb0-1f3b-48aa-b214-099370e1abeb
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 575 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247cd3
Analysis symbol:
Rechecking for solution: 0
Report Id: b2443eb5-9877-49c2-868e-2cbd07ed0542
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 574 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247bc9
Analysis symbol:
Rechecking for solution: 0
Report Id: 0f3622f6-2326-4a80-aa0f-0a6772dd4415
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 573 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247aa0
Analysis symbol:
Rechecking for solution: 0
Report Id: 4ebec750-9387-4d95-9769-28224f169f4a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 572 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:50 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247987
Analysis symbol:
Rechecking for solution: 0
Report Id: b0e05cac-c094-45da-9814-088dcbe95e46
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 571 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1024785e
Analysis symbol:
Rechecking for solution: 0
Report Id: 44a22623-f5f8-49f1-8c32-53177a4908a3
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 570 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247716
Analysis symbol:
Rechecking for solution: 0
Report Id: 9e47d18d-95f8-42f7-86a2-efa9aec59f97
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 569 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1024761c
Analysis symbol:
Rechecking for solution: 0
Report Id: 1e6d0df0-61c8-445a-b9a7-a805a0f2b227
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 568 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10247512
Analysis symbol:
Rechecking for solution: 0
Report Id: 75cce466-b1f9-4111-accb-9649c2b946ba
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 567 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_102473da
Analysis symbol:
Rechecking for solution: 0
Report Id: c22f0024-6c99-4e8d-8694-eeb2d979090a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 566 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:48 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_102472e0
Analysis symbol:
Rechecking for solution: 0
Report Id: eee6891c-6527-4445-9ab7-1bb2cf31426c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 565 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_102471d6
Analysis symbol:
Rechecking for solution: 0
Report Id: 4289b80a-4980-40d4-aa36-3e53278eb635
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 564 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_102470ad
Analysis symbol:
Rechecking for solution: 0
Report Id: e3a695e9-75e7-478e-b88b-c33393eaa0b3
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 563 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10246f75
Analysis symbol:
Rechecking for solution: 0
Report Id: 47a10e01-b1ac-470d-8cb9-625031e387ea
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 562 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10a86f27
Analysis symbol:
Rechecking for solution: 0
Report Id: 80da7992-dfc3-417d-b124-0f9d4395f170
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 561 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:47 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xc6c
Faulting application start time: 0x01d6ce12dd23941e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 80da7992-dfc3-417d-b124-0f9d4395f170
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 560 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_09786e7b
Analysis symbol:
Rechecking for solution: 0
Report Id: ae944871-35c4-43f8-8e96-b43c1f5201ea
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 559 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10246e5c
Analysis symbol:
Rechecking for solution: 0
Report Id: b84ac228-fe6c-4655-8217-4b226232ef49
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 558 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x138c
Faulting application start time: 0x01d6ce12dd0b7de8
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ae944871-35c4-43f8-8e96-b43c1f5201ea
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 557 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05d46ddf
Analysis symbol:
Rechecking for solution: 0
Report Id: d89e7e39-5ea2-47a8-8f62-b229ceec36de
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 556 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xcb0
Faulting application start time: 0x01d6ce12dcef4327
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d89e7e39-5ea2-47a8-8f62-b229ceec36de
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 555 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10246d14
Analysis symbol:
Rechecking for solution: 0
Report Id: af96f9bd-db13-4680-a3a4-bc04de277ab3
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 554 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0fd86d33
Analysis symbol:
Rechecking for solution: 0
Report Id: eb6f55ca-17e5-426f-a01a-696877bee828
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 553 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10b0
Faulting application start time: 0x01d6ce12dcd58bdb
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: eb6f55ca-17e5-426f-a01a-696877bee828
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 552 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ecc6c97
Analysis symbol:
Rechecking for solution: 0
Report Id: 1356a38c-a0d3-433f-a88f-285bfc2442bf
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 551 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x44c
Faulting application start time: 0x01d6ce12dcbccff3
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1356a38c-a0d3-433f-a88f-285bfc2442bf
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 550 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10246b20
Analysis symbol:
Rechecking for solution: 0
Report Id: 7e736c7a-41eb-4380-8f57-d0e1b5ee04fc
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 549 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10f86bdb
Analysis symbol:
Rechecking for solution: 0
Report Id: 95b2d346-db49-4c2b-9283-b6e377bb4718
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 548 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xf5c
Faulting application start time: 0x01d6ce12dc9f08d9
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 95b2d346-db49-4c2b-9283-b6e377bb4718
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 547 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:46 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11786b20
Analysis symbol:
Rechecking for solution: 0
Report Id: 82647c30-27b0-46bd-beb8-07365d90840b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 546 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x13f8
Faulting application start time: 0x01d6ce12dc838f9b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 82647c30-27b0-46bd-beb8-07365d90840b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 545 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02f46a54
Analysis symbol:
Rechecking for solution: 0
Report Id: d2006db5-90b3-4526-910a-00ae10a65be7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 544 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10246a16
Analysis symbol:
Rechecking for solution: 0
Report Id: 0f3d8638-b46e-4094-85d6-75dad385e620
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 543 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x764
Faulting application start time: 0x01d6ce12dc65f8d7
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d2006db5-90b3-4526-910a-00ae10a65be7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 542 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e7869a9
Analysis symbol:
Rechecking for solution: 0
Report Id: 7e9cd866-e8cd-4b01-9ca3-e8675b6d44a9
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 541 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x68
Faulting application start time: 0x01d6ce12dc4d433a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7e9cd866-e8cd-4b01-9ca3-e8675b6d44a9
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 540 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_102468be
Analysis symbol:
Rechecking for solution: 0
Report Id: 760d79f5-46b0-4a67-a267-268c069eb12e
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 539 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0cf068fd
Analysis symbol:
Rechecking for solution: 0
Report Id: 264e5024-873e-4bf8-88da-5afe85536fa9
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 538 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x914
Faulting application start time: 0x01d6ce12dc301314
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 264e5024-873e-4bf8-88da-5afe85536fa9
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 537 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_133c6841
Analysis symbol:
Rechecking for solution: 0
Report Id: 7641c0bc-31b9-4e61-8cc1-28ff03a2a725
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 536 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x6a4
Faulting application start time: 0x01d6ce12dc1787db
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7641c0bc-31b9-4e61-8cc1-28ff03a2a725
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 535 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_128c67a5
Analysis symbol:
Rechecking for solution: 0
Report Id: 07d37d7d-f94d-4208-8e9c-1b954190038d
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 534 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1174
Faulting application start time: 0x01d6ce12dbfe20db
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 07d37d7d-f94d-4208-8e9c-1b954190038d
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 533 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:45 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12786709
Analysis symbol:
Rechecking for solution: 0
Report Id: 0708c534-3a7f-42a8-893b-f75369222c0f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 532 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1248
Faulting application start time: 0x01d6ce12dbe4719e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0708c534-3a7f-42a8-893b-f75369222c0f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 531 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_07f4663e
Analysis symbol:
Rechecking for solution: 0
Report Id: eefc754c-d685-4611-88c0-3c7ddeffe624
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 530 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11ec
Faulting application start time: 0x01d6ce12dbc99c05
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: eefc754c-d685-4611-88c0-3c7ddeffe624
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 529 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12f86582
Analysis symbol:
Rechecking for solution: 0
Report Id: 45495070-b315-4165-938c-cd9dcfa9b009
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 528 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124064f5
Analysis symbol:
Rechecking for solution: 0
Report Id: 82eaad13-0a56-45e8-82a8-60f742464812
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 527 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x9d8
Faulting application start time: 0x01d6ce12dbac50e8
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 45495070-b315-4165-938c-cd9dcfa9b009
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 526 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12a864d6
Analysis symbol:
Rechecking for solution: 0
Report Id: b3bbd839-8908-4ddf-9d8b-e525444f6579
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 525 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xd04
Faulting application start time: 0x01d6ce12db90713f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b3bbd839-8908-4ddf-9d8b-e525444f6579
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 524 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ec641b
Analysis symbol:
Rechecking for solution: 0
Report Id: e4a97a6a-e6cd-4962-b757-5eefc494f32a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 523 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124063ec
Analysis symbol:
Rechecking for solution: 0
Report Id: 1eee9268-3bbf-4741-a2c5-6b3607d04194
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 522 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x133c
Faulting application start time: 0x01d6ce12db717298
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e4a97a6a-e6cd-4962-b757-5eefc494f32a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 521 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1220636f
Analysis symbol:
Rechecking for solution: 0
Report Id: 268decb0-1f3b-48aa-b214-099370e1abeb
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 520 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:44 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xd70
Faulting application start time: 0x01d6ce12db574963
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 268decb0-1f3b-48aa-b214-099370e1abeb
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 519 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124062b3
Analysis symbol:
Rechecking for solution: 0
Report Id: 60c819c6-b47a-470b-9822-4b8a6e50609a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 518 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_103062b3
Analysis symbol:
Rechecking for solution: 0
Report Id: b2443eb5-9877-49c2-868e-2cbd07ed0542
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 517 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x4e8
Faulting application start time: 0x01d6ce12db3b38c5
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b2443eb5-9877-49c2-868e-2cbd07ed0542
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 516 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06cc6207
Analysis symbol:
Rechecking for solution: 0
Report Id: 0f3622f6-2326-4a80-aa0f-0a6772dd4415
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 515 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1240618a
Analysis symbol:
Rechecking for solution: 0
Report Id: 6f4a7236-b491-43f0-a952-703ed51c45a7
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 514 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x122c
Faulting application start time: 0x01d6ce12db218a4d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0f3622f6-2326-4a80-aa0f-0a6772dd4415
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 513 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10a4614c
Analysis symbol:
Rechecking for solution: 0
Report Id: 4ebec750-9387-4d95-9769-28224f169f4a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 512 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x67c
Faulting application start time: 0x01d6ce12db05a6b6
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4ebec750-9387-4d95-9769-28224f169f4a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 511 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11786090
Analysis symbol:
Rechecking for solution: 0
Report Id: b0e05cac-c094-45da-9814-088dcbe95e46
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 510 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12405fe5
Analysis symbol:
Rechecking for solution: 0
Report Id: d38ac6f5-8695-49ca-aa90-d293dcd5ab57
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 509 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x13a8
Faulting application start time: 0x01d6ce12dae70fc4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b0e05cac-c094-45da-9814-088dcbe95e46
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 508 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d105fb6
Analysis symbol:
Rechecking for solution: 0
Report Id: 44a22623-f5f8-49f1-8c32-53177a4908a3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 507 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:43 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x988
Faulting application start time: 0x01d6ce12dac8e65e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 44a22623-f5f8-49f1-8c32-53177a4908a3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 506 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a885f19
Analysis symbol:
Rechecking for solution: 0
Report Id: 9e47d18d-95f8-42f7-86a2-efa9aec59f97
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 505 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12405ecb
Analysis symbol:
Rechecking for solution: 0
Report Id: 5e3d2c30-115f-4b40-a482-1ad9a41693fb
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 504 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x13dc
Faulting application start time: 0x01d6ce12daaf8a83
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9e47d18d-95f8-42f7-86a2-efa9aec59f97
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 503 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0aa85e5e
Analysis symbol:
Rechecking for solution: 0
Report Id: 1e6d0df0-61c8-445a-b9a7-a805a0f2b227
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 502 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12e4
Faulting application start time: 0x01d6ce12da923056
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1e6d0df0-61c8-445a-b9a7-a805a0f2b227
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 501 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12405d83
Analysis symbol:
Rechecking for solution: 0
Report Id: 090b9ac0-9da8-4ff9-940f-4849f5772d4e
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 500 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11ec5da2
Analysis symbol:
Rechecking for solution: 0
Report Id: 75cce466-b1f9-4111-accb-9649c2b946ba
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 499 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12c4
Faulting application start time: 0x01d6ce12da74c43f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 75cce466-b1f9-4111-accb-9649c2b946ba
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 498 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c205ce7
Analysis symbol:
Rechecking for solution: 0
Report Id: c22f0024-6c99-4e8d-8694-eeb2d979090a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 497 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12405c89
Analysis symbol:
Rechecking for solution: 0
Report Id: 3df01014-b5bb-4eab-8b85-457508fd464f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 496 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xd4c
Faulting application start time: 0x01d6ce12da5818b8
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: c22f0024-6c99-4e8d-8694-eeb2d979090a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 495 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12545c2b
Analysis symbol:
Rechecking for solution: 0
Report Id: eee6891c-6527-4445-9ab7-1bb2cf31426c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 494 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1090
Faulting application start time: 0x01d6ce12da3b7cef
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: eee6891c-6527-4445-9ab7-1bb2cf31426c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 493 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12405b31
Analysis symbol:
Rechecking for solution: 0
Report Id: adbfca61-2ec6-4813-b523-8773dcbc29a0
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 492 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:42 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12905b60
Analysis symbol:
Rechecking for solution: 0
Report Id: 4289b80a-4980-40d4-aa36-3e53278eb635
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 491 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1240
Faulting application start time: 0x01d6ce12da155d56
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 4289b80a-4980-40d4-aa36-3e53278eb635
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 490 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11445a76
Analysis symbol:
Rechecking for solution: 0
Report Id: e3a695e9-75e7-478e-b88b-c33393eaa0b3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 489 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1174
Faulting application start time: 0x01d6ce12d9faf7ba
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e3a695e9-75e7-478e-b88b-c33393eaa0b3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 488 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124059da
Analysis symbol:
Rechecking for solution: 0
Report Id: 630b8d32-373c-43e1-8636-d1601f6e0b54
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 487 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_123059ca
Analysis symbol:
Rechecking for solution: 0
Report Id: 47a10e01-b1ac-470d-8cb9-625031e387ea
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 486 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x10fc
Faulting application start time: 0x01d6ce12d9dea8b3
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 47a10e01-b1ac-470d-8cb9-625031e387ea
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 485 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1008590f
Analysis symbol:
Rechecking for solution: 0
Report Id: b84ac228-fe6c-4655-8217-4b226232ef49
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 484 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124058c0
Analysis symbol:
Rechecking for solution: 0
Report Id: 2c6d5ddf-c2c3-4e5c-a27f-0b7a90efd4d9
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 483 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1110
Faulting application start time: 0x01d6ce12d9c42afb
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b84ac228-fe6c-4655-8217-4b226232ef49
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 482 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13105853
Analysis symbol:
Rechecking for solution: 0
Report Id: af96f9bd-db13-4680-a3a4-bc04de277ab3
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 481 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x268
Faulting application start time: 0x01d6ce12d9a411a5
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: af96f9bd-db13-4680-a3a4-bc04de277ab3
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 480 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05745798
Analysis symbol:
Rechecking for solution: 0
Report Id: 7e736c7a-41eb-4380-8f57-d0e1b5ee04fc
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 479 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x228
Faulting application start time: 0x01d6ce12d98b128a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7e736c7a-41eb-4380-8f57-d0e1b5ee04fc
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 478 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0cc856ec
Analysis symbol:
Rechecking for solution: 0
Report Id: 0f3d8638-b46e-4094-85d6-75dad385e620
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 477 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11dc
Faulting application start time: 0x01d6ce12d9703370
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0f3d8638-b46e-4094-85d6-75dad385e620
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 476 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13685621
Analysis symbol:
Rechecking for solution: 0
Report Id: 760d79f5-46b0-4a67-a267-268c069eb12e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 475 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x119c
Faulting application start time: 0x01d6ce12d94f959c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 760d79f5-46b0-4a67-a267-268c069eb12e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 474 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_06885575
Analysis symbol:
Rechecking for solution: 0
Report Id: 82eaad13-0a56-45e8-82a8-60f742464812
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 473 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_111054e8
Analysis symbol:
Rechecking for solution: 0
Report Id: 49505cf1-8a13-478f-acb8-492adea1588c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 472 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xf20
Faulting application start time: 0x01d6ce12d9354581
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 82eaad13-0a56-45e8-82a8-60f742464812
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 471 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_125c54aa
Analysis symbol:
Rechecking for solution: 0
Report Id: 1eee9268-3bbf-4741-a2c5-6b3607d04194
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 470 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1360
Faulting application start time: 0x01d6ce12d91a1f0b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 1eee9268-3bbf-4741-a2c5-6b3607d04194
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 469 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1058541d
Analysis symbol:
Rechecking for solution: 0
Report Id: 60c819c6-b47a-470b-9822-4b8a6e50609a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 468 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:40 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11d4
Faulting application start time: 0x01d6ce12d8ff0c24
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 60c819c6-b47a-470b-9822-4b8a6e50609a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 467 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10a05352
Analysis symbol:
Rechecking for solution: 0
Report Id: 6f4a7236-b491-43f0-a952-703ed51c45a7
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 466 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x68c
Faulting application start time: 0x01d6ce12d8e2dc16
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 6f4a7236-b491-43f0-a952-703ed51c45a7
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 465 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0be852a6
Analysis symbol:
Rechecking for solution: 0
Report Id: d38ac6f5-8695-49ca-aa90-d293dcd5ab57
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 464 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xfc8
Faulting application start time: 0x01d6ce12d8c78d92
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d38ac6f5-8695-49ca-aa90-d293dcd5ab57
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 463 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10dc51fa
Analysis symbol:
Rechecking for solution: 0
Report Id: 5e3d2c30-115f-4b40-a482-1ad9a41693fb
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 462 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xd2c
Faulting application start time: 0x01d6ce12d8ad6594
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 5e3d2c30-115f-4b40-a482-1ad9a41693fb
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 461 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_036c513f
Analysis symbol:
Rechecking for solution: 0
Report Id: 090b9ac0-9da8-4ff9-940f-4849f5772d4e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 460 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1238
Faulting application start time: 0x01d6ce12d891fde4
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 090b9ac0-9da8-4ff9-940f-4849f5772d4e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 459 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2020?-?12?-?09T10:05:30.505817600Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 458 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 600 | 4996 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11ac50a2
Analysis symbol:
Rechecking for solution: 0
Report Id: 3df01014-b5bb-4eab-8b85-457508fd464f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 457 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x69c
Faulting application start time: 0x01d6ce12d878c85b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 3df01014-b5bb-4eab-8b85-457508fd464f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 456 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04244fd7
Analysis symbol:
Rechecking for solution: 0
Report Id: adbfca61-2ec6-4813-b523-8773dcbc29a0
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 455 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x8cc
Faulting application start time: 0x01d6ce12d859124c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: adbfca61-2ec6-4813-b523-8773dcbc29a0
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 454 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124c4efc
Analysis symbol:
Rechecking for solution: 0
Report Id: 630b8d32-373c-43e1-8636-d1601f6e0b54
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 453 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x126c
Faulting application start time: 0x01d6ce12d836611a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 630b8d32-373c-43e1-8636-d1601f6e0b54
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 452 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_047c4e22
Analysis symbol:
Rechecking for solution: 0
Report Id: 2c6d5ddf-c2c3-4e5c-a27f-0b7a90efd4d9
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 451 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe64
Faulting application start time: 0x01d6ce12d818706a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 2c6d5ddf-c2c3-4e5c-a27f-0b7a90efd4d9
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 450 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04284d76
Analysis symbol:
Rechecking for solution: 0
Report Id: 49505cf1-8a13-478f-acb8-492adea1588c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 449 | Windows Error Reporting | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4548. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 448 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 447 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 446 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1190
Faulting application start time: 0x01d6ce12d7bfb820
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 49505cf1-8a13-478f-acb8-492adea1588c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 445 | Application Error | | Application | | | hv-osbrick-7374 | | 12/9/2020 10:05:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2020?-?12?-?09T10:05:30.505817600Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 444 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 600 | 2452 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 10:05:30 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4548. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 443 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 10:05:29 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 442 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 1968 | hv-osbrick-7374 | | 12/9/2020 10:05:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root list with effective date: ?Monday, ?October ?12, ?2020 9:49:04 PM. | 4111 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 441 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 440 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 439 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 438 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 437 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 436 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 435 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 434 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 4292 | hv-osbrick-7374 | | 12/9/2020 10:00:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 433 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 4640 | 3120 | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:55:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2020?-?12?-?09T09:54:58.616666200Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 432 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3136 | 3868 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:59 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4748. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 431 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:54:59 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 430 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:59 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 429 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:59 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2020?-?12?-?09T09:54:58.616666200Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 428 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3136 | 4768 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2020?-?12?-?09T09:54:57.702351900Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 427 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3136 | 3868 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2020?-?12?-?09T09:54:57.702351900Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 426 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3136 | 4292 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4748. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 425 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4748. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 424 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:54:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 423 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 422 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:58 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4748. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 421 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:57 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0. | 1035 | | 0 | 4 | 0 | | 36028797018963968 | 420 | MsiInstaller | | Application | | | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:54:49 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2020?-?12?-?09T09:54:04.689687200Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 419 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 920 | 5052 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2020?-?12?-?09T09:54:04.667550700Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 418 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 920 | 5052 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1001 | 12/9/2020 9:54:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 417 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 1768 | hv-osbrick-7374 | | 12/9/2020 9:53:26 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 416 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2020-12-10T09:50:54Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 415 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:54 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 414 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/06/07:09:51:21;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 413 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:23 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 412 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259200 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 411 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 410 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 409 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
These policies are being excluded since they are only defined with override-only attribute.
Policy Names=(Security-SPP-Reserved-EnableNotificationMode)
App Id=55c92734-d682-4d71-983e-d6ec3f16059f
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1033 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 408 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 407 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Validity period has been started. Validity minutes=259200 Grace type=9. | 1036 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 406 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MSA client has been successfully triggered to update the Device License | 12311 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 405 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:19 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f} | 12304 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 404 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:18 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f | 12305 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 403 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:18 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection ended.
| 20489 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 402 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 401 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check passed.
| 20482 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 400 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check initiated.
| 20481 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 399 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection started.
| 20488 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 398 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS.
| 1067 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 397 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE}
License Id=01dfce3b-bba5-49a6-9071-78d4220b6a21 | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 396 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC}
License Id=d58ec43c-c044-4369-993f-4a5294d9bd1b | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 395 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Acquisition of End User License was successful.
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1013 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 394 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 393 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 1968 | hv-osbrick-7374 | | 12/9/2020 9:51:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2020/12/19:09:46:03;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 392 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:51:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
MSDTC started with the following settings:
Security Configuration (OFF = 0 and ON = 1):
Allow Remote Administrator = 0,
Network Clients = 0,
Transaction Manager Communication:
Allow Inbound Transactions = 0,
Allow Outbound Transactions = 0,
Transaction Internet Protocol (TIP) = 0,
Enable XA Transactions = 0,
Enable SNA LU 6.2 Transactions = 1,
MSDTC Communications Security = Mutual Authentication Required,
Account = NT AUTHORITY\NetworkService,
Firewall Exclusion Detected = 0
Transaction Bridge Installed = 0
Filtering Duplicate Events = 1
| 4202 | 0 | 16384 | 4 | 2 | 0 | 36028797018963968 | 391 | Microsoft-Windows-MSDTC 2 | 5d9e0020-3761-4f36-90c8-38ce6511bd12 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:50:28 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | TM | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 390 | cloudbase-init | | Application | | | hv-osbrick-7374 | | 12/9/2020 9:49:21 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14397)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 389 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:49:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 388 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 560 | 3140 | hv-osbrick-7374 | S-1-5-21-3833588981-2793807358-1089212863-1000 | 12/9/2020 9:49:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service failed to create default configuration for new user 'HV-OSBRICK-7374\Admin' in response to user profile creation. Error code 0x80070005.
Access is denied.
. | 6 | 0 | 49152 | 2 | 0 | 0 | 36028797018963968 | 387 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:49:07 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 386 | cloudbase-init | | Application | | | hv-osbrick-7374 | | 12/9/2020 9:48:29 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service has created default configuration for new user 'HV-OSBRICK-7374\cloudbase-init' .
| 5 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 385 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:48:25 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 384 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1340 | 1764 | hv-osbrick-7374 | | 12/9/2020 9:48:19 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 383 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 560 | 1960 | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:48:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 382 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:48:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 381 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:48:16 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Proof of Purchase installed successfully.
ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4
PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845 | 1016 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 380 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:48:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 379 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 560 | 1280 | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:48:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 378 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 560 | 1684 | hv-osbrick-7374 | S-1-5-18 | 12/9/2020 9:48:14 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 377 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | hv-osbrick-7374 | | 12/9/2020 9:48:15 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 376 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 520 | 1492 | WIN-5T344G8GM1H | S-1-5-18 | 12/9/2020 9:47:33 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 375 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 12/9/2020 9:47:33 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of disallowed certificate list with effective date: ?Tuesday, ?September ?15, ?2020 5:56:35 PM. | 4112 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 374 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1652 | 1756 | WIN-5T344G8GM1H | | 12/9/2020 9:46:20 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de}
Writer Name: Microsoft Hyper-V VSS Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 373 | VSS | | Application | | | WIN-5T344G8GM1H | | 12/9/2020 9:46:14 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 372 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 520 | 516 | WIN-5T344G8GM1H | S-1-5-18 | 12/9/2020 9:46:06 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 371 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 520 | 1580 | WIN-5T344G8GM1H | S-1-5-18 | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 370 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 520 | 1492 | WIN-5T344G8GM1H | S-1-5-18 | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f}
Writer Name: Shadow Copy Optimization Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 369 | VSS | | Application | | | WIN-5T344G8GM1H | | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4}
Writer Name: ASR Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 368 | VSS | | Application | | | WIN-5T344G8GM1H | | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f}
Writer Name: COM+ REGDB Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 367 | VSS | | Application | | | WIN-5T344G8GM1H | | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485}
Writer Name: Registry Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 366 | VSS | | Application | | | WIN-5T344G8GM1H | | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 365 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | WIN-4EN3P9PJDGV | | 12/9/2020 9:46:05 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 364 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 1228 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required.
DETAIL -
9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500:
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore
Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main
Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security
| 1530 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 363 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 3432 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The winlogon notification subscriber <SessionEnv> failed a notification event. | 6001 | 0 | 32768 | 3 | 0 | 0 | 36028797018963968 | 362 | Microsoft-Windows-Winlogon | dbe9b383-7cf3-4331-91cc-a3cb16a3b538 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 361 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448 | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 360 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 359 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining. | 12306 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 358 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 357 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 356 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Grace period has been started. Grace days=10 Grace type=6. | 1025 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 355 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 354 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The hardware has changed. | 1024 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 353 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Hardware has changed from previous boot.
AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4. | 1040 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 352 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 351 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=Sysprep.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 350 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MS DTC service is stopping. | 4111 | 0 | 16384 | 4 | 1 | 0 | 36028797018963968 | 349 | Microsoft-Windows-MSDTC | 719be4ed-e9bc-4dd8-a7cf-c85ce8e4975d | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:47:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | SVC | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |