MessageIdVersionQualifiersLevelTaskOpcodeKeywordsRecordIdProviderNameProviderIdLogNameProcessIdThreadIdMachineNameUserIdTimeCreatedActivityIdRelatedActivityIdContainerLogMatchedQueryIdsBookmarkLevelDisplayNameOpcodeDisplayNameTaskDisplayNameKeywordsDisplayNamesProperties
The Software Protection service has stopped. 90301638400036028797018963968608Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:48:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T19:47:23Z. Reason: TBL.1638401638440036028797018963968607Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:48:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968606Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259031 minutes.103703276840036028797018963968605Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259031)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968604Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968603Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968602Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968601Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:18:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T19:17:23Z. Reason: TBL.1638401638440036028797018963968600Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:18:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968599Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:17:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259061 minutes.103703276840036028797018963968598Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:17:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259061)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968597Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:17:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968596Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:17:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968595Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 7:17:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968594Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:48:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T18:47:23Z. Reason: TBL.1638401638440036028797018963968593Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:48:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968592Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259091 minutes.103703276840036028797018963968591Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259091)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968590Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968589Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968588Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968587Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:18:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T18:17:22Z. Reason: TBL.1638401638440036028797018963968586Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:18:23 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968585Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:17:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259121 minutes.103703276840036028797018963968584Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:17:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259121)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968583Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:17:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968582Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:17:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968581Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 6:17:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808580Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application45004696n-h2-766043-1.cbci-766043-1.localS-1-5-1812/8/2020 5:55:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127afaf0 Analysis symbol: Rechecking for solution: 0 Report Id: ee3a7a88-8f67-4635-afd6-0ac8a2957700 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968579Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127afa06 Analysis symbol: Rechecking for solution: 0 Report Id: dbc6f8c4-8de5-4787-ab7a-e0002e3ecd95 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968578Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af90c Analysis symbol: Rechecking for solution: 0 Report Id: 72df8de3-9924-4e4b-a79e-6dc3de849494 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968577Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af821 Analysis symbol: Rechecking for solution: 0 Report Id: 23156b48-2195-427a-a3fc-afc31cbce190 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968576Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af718 Analysis symbol: Rechecking for solution: 0 Report Id: 892169ec-a38f-4ded-a865-f8b420c6f461 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968575Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af62d Analysis symbol: Rechecking for solution: 0 Report Id: 5423db4e-7cb8-477e-b0b8-10a317c0bfc8 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968574Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af439 Analysis symbol: Rechecking for solution: 0 Report Id: 461c2718-06b5-4593-9f8d-54169df6c6e7 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968573Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af33f Analysis symbol: Rechecking for solution: 0 Report Id: 404eac8b-b205-4a73-80de-9e5f33596e52 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968572Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af236 Analysis symbol: Rechecking for solution: 0 Report Id: 4ebe1b7c-7fb7-4a22-a236-53f3296612df Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968571Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af14b Analysis symbol: Rechecking for solution: 0 Report Id: 2d497522-f447-417e-a8f4-684d6020a802 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968570Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127af061 Analysis symbol: Rechecking for solution: 0 Report Id: d54c2c6d-8c79-40d3-a0e3-26449523fd4c Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968569Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_127aef77 Analysis symbol: Rechecking for solution: 0 Report Id: 6d29ca24-4a58-4a70-9fc7-1dd91d79297f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968568Windows Error ReportingApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968567Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T17:49:24Z. Reason: TBL.1638401638440036028797018963968566Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:50:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968565Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:49:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259149 minutes.103703276840036028797018963968564Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:49:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259149)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968563Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:49:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968562Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:49:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:<none>90001638440036028797018963968561Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:49:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968560Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:49:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968559neutron-ovs-agentApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:48:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968558nova-computeApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:48:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'CBCI-766043-1\administrator' . 501638440036028797018963968557Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:48:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968556Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:48:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T17:47:36Z. Reason: TBL.1638401638440036028797018963968555Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:48:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968554cloudbase-initApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:48:17 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Security policy in the Group policy objects has been applied successfully.1704163844036028797018963968553SceCliApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808552Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication14842296n-h2-766043-1.cbci-766043-1.localS-1-5-1812/8/2020 5:47:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968551cloudbase-initApplicationn-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968550Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259151 minutes.103703276840036028797018963968549Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259151)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968548Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968547Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968546Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-1.cbci-766043-1.local12/8/2020 5:47:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808545Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication14841560n-h2-766043-1.cbci-766043-1.localS-1-5-1812/8/2020 5:47:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808544Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application14841524n-h2-766043-1.cbci-766043-1.localS-1-5-1812/8/2020 5:47:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808543Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5841780n-h2-766043-1S-1-5-1812/8/2020 5:47:28 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The VSS service is shutting down due to shutdown event from the Service Control Manager. 822504036028797018963968542VSSApplicationn-h2-766043-112/8/2020 5:47:28 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968541Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00n-h2-766043-112/8/2020 5:47:28 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968540Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:26:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T17:25:10Z. Reason: TBL.1638401638440036028797018963968539Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:26:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968538Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:25:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259174 minutes.103703276840036028797018963968537Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:25:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968536Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:25:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968535Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:25:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968534Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 5:25:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808533Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application8441216n-h2-766043-1S-1-5-1812/8/2020 5:21:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_138647f1 Analysis symbol: Rechecking for solution: 0 Report Id: eac25f7f-252f-4e02-8b20-0a3135ec603f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968532Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_138646c9 Analysis symbol: Rechecking for solution: 0 Report Id: da7130e9-9a2f-4ea4-aae8-98df908bd38a Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968531Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_138645a0 Analysis symbol: Rechecking for solution: 0 Report Id: fe9ca6ca-b8f6-412c-88a8-ac88df5fe150 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968530Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13864467 Analysis symbol: Rechecking for solution: 0 Report Id: 81feb16d-37e7-4769-903e-22aab5b98eee Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968529Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1386432f Analysis symbol: Rechecking for solution: 0 Report Id: a7b5b9ed-8764-48eb-a866-9016d37e8d84 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968528Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13864206 Analysis symbol: Rechecking for solution: 0 Report Id: a3a303b1-e6c7-4882-b768-37cae056de21 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968527Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_138640dd Analysis symbol: Rechecking for solution: 0 Report Id: c91a08c4-bc4f-450d-a6be-e542b5461e46 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968526Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13863f76 Analysis symbol: Rechecking for solution: 0 Report Id: 887ab032-2842-4d42-afd8-a2b930f8801e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968525Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10663f27 Analysis symbol: Rechecking for solution: 0 Report Id: ee3a7a88-8f67-4635-afd6-0ac8a2957700 Report Status: 4 Hashed bucket: 100104036028797018963968524Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xa34 Faulting application start time: 0x01d6cd8513a2dfc0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ee3a7a88-8f67-4635-afd6-0ac8a2957700 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968523Application ErrorApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13863e2d Analysis symbol: Rechecking for solution: 0 Report Id: 5ed6e521-97af-45d1-a649-d7b1df5d6eb1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968522Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_065e3dff Analysis symbol: Rechecking for solution: 0 Report Id: dbc6f8c4-8de5-4787-ab7a-e0002e3ecd95 Report Status: 4 Hashed bucket: 100104036028797018963968521Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xd88 Faulting application start time: 0x01d6cd851374b065 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: dbc6f8c4-8de5-4787-ab7a-e0002e3ecd95 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968520Application ErrorApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13863cb6 Analysis symbol: Rechecking for solution: 0 Report Id: 0f7475af-32d9-49f3-a88d-45cca42124d3 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968519Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124a3ce5 Analysis symbol: Rechecking for solution: 0 Report Id: 72df8de3-9924-4e4b-a79e-6dc3de849494 Report Status: 4 Hashed bucket: 100104036028797018963968518Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x580 Faulting application start time: 0x01d6cd851348d293 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 72df8de3-9924-4e4b-a79e-6dc3de849494 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968517Application ErrorApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11ce3bdc Analysis symbol: Rechecking for solution: 0 Report Id: 23156b48-2195-427a-a3fc-afc31cbce190 Report Status: 4 Hashed bucket: 100104036028797018963968516Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13863b6e Analysis symbol: Rechecking for solution: 0 Report Id: 47de550f-7b0c-4053-8933-fd79eed6d678 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968515Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1084 Faulting application start time: 0x01d6cd85131eb1d9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 23156b48-2195-427a-a3fc-afc31cbce190 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968514Application ErrorApplicationn-h2-766043-112/8/2020 5:10:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12323a94 Analysis symbol: Rechecking for solution: 0 Report Id: 892169ec-a38f-4ded-a865-f8b420c6f461 Report Status: 4 Hashed bucket: 100104036028797018963968513Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1386396b Analysis symbol: Rechecking for solution: 0 Report Id: 5317026b-2689-4b3c-8685-eca89ac000fa Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968512Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x910 Faulting application start time: 0x01d6cd8512f21ffa Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 892169ec-a38f-4ded-a865-f8b420c6f461 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968511Application ErrorApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1392396b Analysis symbol: Rechecking for solution: 0 Report Id: 5423db4e-7cb8-477e-b0b8-10a317c0bfc8 Report Status: 4 Hashed bucket: 100104036028797018963968510Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe8c Faulting application start time: 0x01d6cd8512c28461 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5423db4e-7cb8-477e-b0b8-10a317c0bfc8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968509Application ErrorApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0dbe3842 Analysis symbol: Rechecking for solution: 0 Report Id: 461c2718-06b5-4593-9f8d-54169df6c6e7 Report Status: 4 Hashed bucket: 100104036028797018963968508Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_138637f4 Analysis symbol: Rechecking for solution: 0 Report Id: bc3e33bd-3ce5-4c55-bf51-b545fa998f6b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968507Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x348 Faulting application start time: 0x01d6cd851297893d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 461c2718-06b5-4593-9f8d-54169df6c6e7 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968506Application ErrorApplicationn-h2-766043-112/8/2020 5:10:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_110e3748 Analysis symbol: Rechecking for solution: 0 Report Id: 404eac8b-b205-4a73-80de-9e5f33596e52 Report Status: 4 Hashed bucket: 100104036028797018963968505Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1234 Faulting application start time: 0x01d6cd85126fda7e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 404eac8b-b205-4a73-80de-9e5f33596e52 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968504Application ErrorApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_094e362f Analysis symbol: Rechecking for solution: 0 Report Id: 4ebe1b7c-7fb7-4a22-a236-53f3296612df Report Status: 4 Hashed bucket: 100104036028797018963968503Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1114 Faulting application start time: 0x01d6cd8512480471 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 4ebe1b7c-7fb7-4a22-a236-53f3296612df Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968502Application ErrorApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ef63535 Analysis symbol: Rechecking for solution: 0 Report Id: 2d497522-f447-417e-a8f4-684d6020a802 Report Status: 4 Hashed bucket: 100104036028797018963968501Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13d4 Faulting application start time: 0x01d6cd85121ff13e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2d497522-f447-417e-a8f4-684d6020a802 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968500Application ErrorApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_094a342b Analysis symbol: Rechecking for solution: 0 Report Id: d54c2c6d-8c79-40d3-a0e3-26449523fd4c Report Status: 4 Hashed bucket: 100104036028797018963968499Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1230 Faulting application start time: 0x01d6cd8511f8f010 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d54c2c6d-8c79-40d3-a0e3-26449523fd4c Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968498Application ErrorApplicationn-h2-766043-112/8/2020 5:10:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f0e3312 Analysis symbol: Rechecking for solution: 0 Report Id: 6d29ca24-4a58-4a70-9fc7-1dd91d79297f Report Status: 4 Hashed bucket: 100104036028797018963968497Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf30 Faulting application start time: 0x01d6cd8511cd9c99 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6d29ca24-4a58-4a70-9fc7-1dd91d79297f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968496Application ErrorApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08be31f8 Analysis symbol: Rechecking for solution: 0 Report Id: eac25f7f-252f-4e02-8b20-0a3135ec603f Report Status: 4 Hashed bucket: 100104036028797018963968495Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1324 Faulting application start time: 0x01d6cd8511a474c5 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: eac25f7f-252f-4e02-8b20-0a3135ec603f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968494Application ErrorApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f7630ef Analysis symbol: Rechecking for solution: 0 Report Id: 75ccfcf2-47f0-4af7-9007-ca689a3e2575 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968493Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13be310e Analysis symbol: Rechecking for solution: 0 Report Id: da7130e9-9a2f-4ea4-aae8-98df908bd38a Report Status: 4 Hashed bucket: 100104036028797018963968492Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x7fc Faulting application start time: 0x01d6cd85117fb117 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: da7130e9-9a2f-4ea4-aae8-98df908bd38a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968491Application ErrorApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12f23024 Analysis symbol: Rechecking for solution: 0 Report Id: fe9ca6ca-b8f6-412c-88a8-ac88df5fe150 Report Status: 4 Hashed bucket: 100104036028797018963968490Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1128 Faulting application start time: 0x01d6cd85115b9813 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: fe9ca6ca-b8f6-412c-88a8-ac88df5fe150 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968489Application ErrorApplicationn-h2-766043-112/8/2020 5:10:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10022f0a Analysis symbol: Rechecking for solution: 0 Report Id: 81feb16d-37e7-4769-903e-22aab5b98eee Report Status: 4 Hashed bucket: 100104036028797018963968488Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f762ebc Analysis symbol: Rechecking for solution: 0 Report Id: 971d276f-9666-4927-918a-7d1aca32bc39 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968487Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x64 Faulting application start time: 0x01d6cd85112f95e9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 81feb16d-37e7-4769-903e-22aab5b98eee Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968486Application ErrorApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d862e20 Analysis symbol: Rechecking for solution: 0 Report Id: a7b5b9ed-8764-48eb-a866-9016d37e8d84 Report Status: 4 Hashed bucket: 100104036028797018963968485Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xea4 Faulting application start time: 0x01d6cd85110cad30 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a7b5b9ed-8764-48eb-a866-9016d37e8d84 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968484Application ErrorApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f762d84 Analysis symbol: Rechecking for solution: 0 Report Id: d0bbd6f0-08b1-4fa5-810c-d581b9b26c2b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968483Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_058e2d36 Analysis symbol: Rechecking for solution: 0 Report Id: a3a303b1-e6c7-4882-b768-37cae056de21 Report Status: 4 Hashed bucket: 100104036028797018963968482Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10b8 Faulting application start time: 0x01d6cd8510e6a2f5 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a3a303b1-e6c7-4882-b768-37cae056de21 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968481Application ErrorApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f762bee Analysis symbol: Rechecking for solution: 0 Report Id: 841b1857-b5ef-4657-b137-7d6c1ff62701 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968480Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02ea2c3c Analysis symbol: Rechecking for solution: 0 Report Id: c91a08c4-bc4f-450d-a6be-e542b5461e46 Report Status: 4 Hashed bucket: 100104036028797018963968479Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1040 Faulting application start time: 0x01d6cd8510c1e59c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: c91a08c4-bc4f-450d-a6be-e542b5461e46 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968478Application ErrorApplicationn-h2-766043-112/8/2020 5:10:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13422b32 Analysis symbol: Rechecking for solution: 0 Report Id: 887ab032-2842-4d42-afd8-a2b930f8801e Report Status: 4 Hashed bucket: 100104036028797018963968477Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11d8 Faulting application start time: 0x01d6cd8510993a09 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 887ab032-2842-4d42-afd8-a2b930f8801e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968476Application ErrorApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f762a96 Analysis symbol: Rechecking for solution: 0 Report Id: 912556c8-44c7-479e-a890-e4cd24f0609c Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968475Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_116e2a38 Analysis symbol: Rechecking for solution: 0 Report Id: 5ed6e521-97af-45d1-a649-d7b1df5d6eb1 Report Status: 4 Hashed bucket: 100104036028797018963968474Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1004 Faulting application start time: 0x01d6cd85106ec33c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5ed6e521-97af-45d1-a649-d7b1df5d6eb1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968473Application ErrorApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f76292e Analysis symbol: Rechecking for solution: 0 Report Id: 7315dac3-c313-4958-95f7-ffd6e7e1a583 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968472Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d562900 Analysis symbol: Rechecking for solution: 0 Report Id: 0f7475af-32d9-49f3-a88d-45cca42124d3 Report Status: 4 Hashed bucket: 100104036028797018963968471Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc8c Faulting application start time: 0x01d6cd851044e369 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0f7475af-32d9-49f3-a88d-45cca42124d3 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968470Application ErrorApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_115627e6 Analysis symbol: Rechecking for solution: 0 Report Id: 47de550f-7b0c-4053-8933-fd79eed6d678 Report Status: 4 Hashed bucket: 100104036028797018963968469Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe8c Faulting application start time: 0x01d6cd851018555a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 47de550f-7b0c-4053-8933-fd79eed6d678 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968468Application ErrorApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0dbe26ec Analysis symbol: Rechecking for solution: 0 Report Id: 5317026b-2689-4b3c-8685-eca89ac000fa Report Status: 4 Hashed bucket: 100104036028797018963968467Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1224 Faulting application start time: 0x01d6cd850ff14b49 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5317026b-2689-4b3c-8685-eca89ac000fa Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968466Application ErrorApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_087a25e3 Analysis symbol: Rechecking for solution: 0 Report Id: bc3e33bd-3ce5-4c55-bf51-b545fa998f6b Report Status: 4 Hashed bucket: 100104036028797018963968465Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1028 Faulting application start time: 0x01d6cd850fca66b6 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: bc3e33bd-3ce5-4c55-bf51-b545fa998f6b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968464Application ErrorApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e8624c9 Analysis symbol: Rechecking for solution: 0 Report Id: 75ccfcf2-47f0-4af7-9007-ca689a3e2575 Report Status: 4 Hashed bucket: 100104036028797018963968463Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0eae247b Analysis symbol: Rechecking for solution: 0 Report Id: 1d46d97e-3f1b-4785-b73c-aa2e41d44b65 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968462Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x56c Faulting application start time: 0x01d6cd850f9dd7a0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 75ccfcf2-47f0-4af7-9007-ca689a3e2575 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968461Application ErrorApplicationn-h2-766043-112/8/2020 5:10:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_121223cf Analysis symbol: Rechecking for solution: 0 Report Id: 971d276f-9666-4927-918a-7d1aca32bc39 Report Status: 4 Hashed bucket: 100104036028797018963968460Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13a4 Faulting application start time: 0x01d6cd850f71d1ff Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 971d276f-9666-4927-918a-7d1aca32bc39 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968459Application ErrorApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_07862278 Analysis symbol: Rechecking for solution: 0 Report Id: d0bbd6f0-08b1-4fa5-810c-d581b9b26c2b Report Status: 4 Hashed bucket: 100104036028797018963968458Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x107c Faulting application start time: 0x01d6cd850f44f0f9 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d0bbd6f0-08b1-4fa5-810c-d581b9b26c2b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968457Application ErrorApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?08T17:10:34.346308400Z.100010400-9223372036854775808456Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application17282264n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_05be217e Analysis symbol: Rechecking for solution: 0 Report Id: 841b1857-b5ef-4657-b137-7d6c1ff62701 Report Status: 4 Hashed bucket: 100104036028797018963968455Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x13f4 Faulting application start time: 0x01d6cd850f210ca6 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 841b1857-b5ef-4657-b137-7d6c1ff62701 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968454Application ErrorApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10a62084 Analysis symbol: Rechecking for solution: 0 Report Id: 912556c8-44c7-479e-a890-e4cd24f0609c Report Status: 4 Hashed bucket: 100104036028797018963968453Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc40 Faulting application start time: 0x01d6cd850ef4d856 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 912556c8-44c7-479e-a890-e4cd24f0609c Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968452Application ErrorApplicationn-h2-766043-112/8/2020 5:10:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11421f5b Analysis symbol: Rechecking for solution: 0 Report Id: 7315dac3-c313-4958-95f7-ffd6e7e1a583 Report Status: 4 Hashed bucket: 100104036028797018963968451Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10ac Faulting application start time: 0x01d6cd850ec8b377 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7315dac3-c313-4958-95f7-ffd6e7e1a583 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968450Application ErrorApplicationn-h2-766043-112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11161e13 Analysis symbol: Rechecking for solution: 0 Report Id: 1d46d97e-3f1b-4785-b73c-aa2e41d44b65 Report Status: 4 Hashed bucket: 100104036028797018963968449Windows Error ReportingApplicationn-h2-766043-112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 2664.104204036028797018963968448MsiInstallerApplicationn-h2-766043-1S-1-5-1812/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0.103304036028797018963968447MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully.1170704036028797018963968446MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xa50 Faulting application start time: 0x01d6cd850e582fba Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1d46d97e-3f1b-4785-b73c-aa2e41d44b65 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968445Application ErrorApplicationn-h2-766043-112/8/2020 5:10:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?08T17:10:34.346308400Z.100000400-9223372036854775808444Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application17284432n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:10:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 2664.104004036028797018963968443MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:10:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.409700400-9187343239835811840442Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401696n-h2-766043-112/8/2020 5:10:28 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root list with effective date: ?Monday, ?October ?12, ?2020 9:49:04 PM.411100400-9187343239835811840441Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>.410900400-9187343239835811840440Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>.410900400-9187343239835811840439Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>.410900400-9187343239835811840438Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.410900400-9187343239835811840437Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.410900400-9187343239835811840436Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>.410900400-9187343239835811840435Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.410900400-9187343239835811840434Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13404352n-h2-766043-112/8/2020 5:07:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808433Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application47964800n-h2-766043-1S-1-5-1812/8/2020 5:02:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?08T17:02:11.967618000Z.100010400-9223372036854775808432Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application5561312n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 3212.104204036028797018963968431MsiInstallerApplicationn-h2-766043-1S-1-5-1812/8/2020 5:02:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968430MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968429MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?08T17:02:11.967618000Z.100000400-9223372036854775808428Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application5564772n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2020?-?12?-?08T17:02:11.175451200Z.100010400-9223372036854775808427Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application5561312n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?08T17:02:11.175451200Z.100000400-9223372036854775808426Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application556100n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 3212.104004036028797018963968425MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 3212.104204036028797018963968424MsiInstallerApplicationn-h2-766043-1S-1-5-1812/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968423MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968422MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 3212.104004036028797018963968421MsiInstallerApplicationn-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:02:10 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0.103504036028797018963968420MsiInstallerApplicationn-h2-766043-1S-1-5-1812/8/2020 5:02:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?08T17:01:18.705057600Z.100000400-9223372036854775808419Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application3824744n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:01:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2020?-?12?-?08T17:01:18.693166000Z.100000400-9223372036854775808418Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application3824744n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100112/8/2020 5:01:18 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.409700400-9187343239835811840417Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401976n-h2-766043-112/8/2020 5:00:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968416Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:59:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2020-12-09T16:58:24Z. Reason: TBL.1638401638440036028797018963968415Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:59:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent819704915240036028797018963968414Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/06/06:16:58:53;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968413Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968412Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259200 minutes.103703276840036028797018963968411Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968410Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968409Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
These policies are being excluded since they are only defined with override-only attribute. Policy Names=(Security-SPP-Reserved-EnableNotificationMode) App Id=55c92734-d682-4d71-983e-d6ec3f16059f Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4103301638440036028797018963968408Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100103401638440036028797018963968407Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Validity period has been started. Validity minutes=259200 Grace type=9.103601638440036028797018963968406Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MSA client has been successfully triggered to update the Device License1231101638440036028797018963968405Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f}1230401638440036028797018963968404Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f1230501638440036028797018963968403Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection ended. 2048904915240036028797018963968402Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:48 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968401Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check passed. 2048204915240036028797018963968400Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:47 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check initiated. 2048104915240036028797018963968399Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection started. 2048804915240036028797018963968398Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS. 106703276840036028797018963968397Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE} License Id=f3c776e2-ed25-4b53-b6cc-32808488d9ec100401638440036028797018963968396Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC} License Id=f859715c-63f5-4cf2-8158-9cdc548d43c1100401638440036028797018963968395Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Acquisition of End User License was successful. Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4101301638400036028797018963968394Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.409700400-9187343239835811840393Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401704n-h2-766043-112/8/2020 4:58:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2020/12/18:16:54:37;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968392Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:58:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968391Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00n-h2-766043-112/8/2020 4:57:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968390cloudbase-initApplicationn-h2-766043-112/8/2020 4:56:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968389Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:56:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied. . 15340300-9223372036854775808388Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5842840n-h2-766043-1S-1-5-21-2267259738-32932096-2985632657-100012/8/2020 4:56:25 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service failed to create default configuration for new user 'N-H2-766043-1\Admin' in response to user profile creation. Error code 0x80070005. Access is denied. .604915220036028797018963968387Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00n-h2-766043-112/8/2020 4:56:25 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968386cloudbase-initApplicationn-h2-766043-112/8/2020 4:55:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'N-H2-766043-1\cloudbase-init' . 501638440036028797018963968385Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00n-h2-766043-112/8/2020 4:55:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.409700400-9187343239835811840384Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13401700n-h2-766043-112/8/2020 4:55:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808383Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5841368n-h2-766043-1S-1-5-1812/8/2020 4:55:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808382Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication584544n-h2-766043-1S-1-5-1812/8/2020 4:55:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808381Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5841780n-h2-766043-1S-1-5-1812/8/2020 4:55:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968380Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:55:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968379Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:55:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Proof of Purchase installed successfully. ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845101601638440036028797018963968378Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-766043-112/8/2020 4:55:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog.462501638440036028797018963968377Microsoft-Windows-EventSystem899daace-4868-4295-afcd-9eb8fb497561Application00n-h2-766043-112/8/2020 4:55:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808376Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5241504WIN-5T344G8GM1HS-1-5-1812/8/2020 4:55:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968375Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H12/8/2020 4:55:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The VSS service is shutting down due to shutdown event from the Service Control Manager. 822504036028797018963968374VSSApplicationWIN-5T344G8GM1H12/8/2020 4:55:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of disallowed certificate list with effective date: ?Tuesday, ?September ?15, ?2020 5:56:35 PM.411200400-9187343239835811840373Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication16561784WIN-5T344G8GM1H12/8/2020 4:53:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Name: Microsoft Hyper-V VSS Writer821204036028797018963968372VSSApplicationWIN-5T344G8GM1H12/8/2020 4:53:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808371Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication524532WIN-5T344G8GM1HS-1-5-1812/8/2020 4:53:46 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808370Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5241572WIN-5T344G8GM1HS-1-5-1812/8/2020 4:53:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808369Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5241504WIN-5T344G8GM1HS-1-5-1812/8/2020 4:53:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} Writer Name: Shadow Copy Optimization Writer821204036028797018963968368VSSApplicationWIN-5T344G8GM1H12/8/2020 4:53:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4} Writer Name: ASR Writer821204036028797018963968367VSSApplicationWIN-5T344G8GM1H12/8/2020 4:53:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f} Writer Name: COM+ REGDB Writer821204036028797018963968366VSSApplicationWIN-5T344G8GM1H12/8/2020 4:53:45 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485} Writer Name: Registry Writer821204036028797018963968365VSSApplicationWIN-5T344G8GM1H12/8/2020 4:53:44 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808364Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9761228WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:13 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required. DETAIL - 9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500: Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security 15300400-9223372036854775808363Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9763432WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The winlogon notification subscriber <SessionEnv> failed a notification event.600103276830036028797018963968362Microsoft-Windows-Winlogondbe9b383-7cf3-4331-91cc-a3cb16a3b538Application00WIN-5T344G8GM1H1/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968361Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448823001638440036028797018963968360Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )] 100301638440036028797018963968359Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining.1230601638440036028797018963968358Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968357Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968356Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Grace period has been started. Grace days=10 Grace type=6.102501638440036028797018963968355Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968354Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The hardware has changed.102403276840036028797018963968353Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Hardware has changed from previous boot. AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4.104001638440036028797018963968352Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968351Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=Sysprep.exe90001638440036028797018963968350Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968349Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00WIN-5T344G8GM1H1/19/2018 9:47:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]