2020-11-04T08:08:13.340Z|00001|vlog|INFO|opened log file C:\Program Files\Cloudbase Solutions\Open vSwitch\logs\ovs-vswitchd.log 2020-11-04T08:08:13.346Z|00002|ovs_numa|INFO|Discovered 0 NUMA nodes and 0 CPU cores 2020-11-04T08:08:13.347Z|00003|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connecting... 2020-11-04T08:08:13.347Z|00004|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connected 2020-11-04T08:08:13.377Z|00005|bridge|INFO|ovs-vswitchd (Open vSwitch) 2.7.0 2020-11-04T08:08:19.219Z|00001|vlog|INFO|opened log file C:\Program Files\Cloudbase Solutions\Open vSwitch\logs\ovs-vswitchd.log 2020-11-04T08:08:19.233Z|00002|ovs_numa|INFO|Discovered 0 NUMA nodes and 0 CPU cores 2020-11-04T08:08:19.233Z|00003|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connecting... 2020-11-04T08:08:19.233Z|00004|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connected 2020-11-04T08:08:19.241Z|00005|bridge|INFO|ovs-vswitchd (Open vSwitch) 2.7.0 2020-11-04T08:08:22.127Z|00001|vlog|INFO|opened log file C:\Program Files\Cloudbase Solutions\Open vSwitch\logs\ovs-vswitchd.log 2020-11-04T08:08:22.132Z|00002|ovs_numa|INFO|Discovered 0 NUMA nodes and 0 CPU cores 2020-11-04T08:08:22.132Z|00003|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connecting... 2020-11-04T08:08:22.133Z|00004|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connected 2020-11-04T08:08:22.178Z|00005|bridge|INFO|ovs-vswitchd (Open vSwitch) 2.7.0 2020-11-04T08:08:32.137Z|00006|memory|INFO|6720 kB peak resident set size after 10.0 seconds 2020-11-04T08:08:38.682Z|00007|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2020-11-04T08:08:38.682Z|00008|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2020-11-04T08:08:38.682Z|00009|ofproto_dpif|INFO|system@ovs-system: datapath does not support masked set action feature. 2020-11-04T08:08:38.682Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2020-11-04T08:08:38.682Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath does not support unique flow ids 2020-11-04T08:08:38.682Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2020-11-04T08:08:38.682Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2020-11-04T08:08:38.682Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2020-11-04T08:08:38.683Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2020-11-04T08:08:38.683Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2020-11-04T08:08:38.683Z|00017|ofproto_dpif|WARN|system@ovs-system: variable-length userdata feature probe failed (Unknown error) 2020-11-04T08:08:38.683Z|00018|ofproto_dpif|WARN|Not supported on Windows 2020-11-04T08:08:39.518Z|00019|bridge|INFO|bridge br-ethernet: added interface br-ethernet on port 65534 2020-11-04T08:08:39.518Z|00020|bridge|INFO|bridge br-ethernet: using datapath ID 00007683b654fc4d 2020-11-04T08:08:39.518Z|00021|connmgr|INFO|br-ethernet: added service controller "punix:C:\ProgramData\openvswitch\/br-ethernet.mgmt" 2020-11-04T08:08:42.149Z|00022|memory|INFO|peak resident set size grew 61% in last 10.0 seconds, from 6720 kB to 10832 kB 2020-11-04T08:08:42.150Z|00023|memory|INFO|handlers:4 ports:1 revalidators:2 rules:5 2020-11-04T08:08:42.345Z|00024|bridge|INFO|bridge br-ethernet: added interface Ethernet on port 1 2020-11-04T08:34:09.596Z|00025|fatal_signal|WARN|terminating with signal 2 2020-11-04T08:34:35.618Z|00001|vlog|INFO|opened log file C:\Program Files\Cloudbase Solutions\Open vSwitch\logs\ovs-vswitchd.log 2020-11-04T08:34:35.632Z|00002|ovs_numa|INFO|Discovered 0 NUMA nodes and 0 CPU cores 2020-11-04T08:34:35.633Z|00003|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connecting... 2020-11-04T08:34:35.635Z|00004|reconnect|INFO|unix:C:\ProgramData\openvswitch\db.sock: connected 2020-11-04T08:34:35.652Z|00005|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2020-11-04T08:34:35.652Z|00006|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2020-11-04T08:34:35.653Z|00007|ofproto_dpif|INFO|system@ovs-system: datapath does not support masked set action feature. 2020-11-04T08:34:35.653Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2020-11-04T08:34:35.653Z|00009|ofproto_dpif|INFO|system@ovs-system: Datapath does not support unique flow ids 2020-11-04T08:34:35.653Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2020-11-04T08:34:35.654Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2020-11-04T08:34:35.654Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2020-11-04T08:34:35.654Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2020-11-04T08:34:35.654Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2020-11-04T08:34:35.654Z|00015|ofproto_dpif|WARN|system@ovs-system: variable-length userdata feature probe failed (Unknown error) 2020-11-04T08:34:35.655Z|00016|ofproto_dpif|WARN|Not supported on Windows 2020-11-04T08:34:35.756Z|00017|wmi|WARN|Port with name: br-ethernet already defined on the switch 2020-11-04T08:34:35.758Z|00018|bridge|INFO|bridge br-ethernet: added interface br-ethernet on port 65534 2020-11-04T08:34:35.758Z|00019|bridge|INFO|bridge br-ethernet: added interface Ethernet on port 1 2020-11-04T08:34:35.758Z|00020|bridge|INFO|bridge br-ethernet: using datapath ID 00007683b654fc4d 2020-11-04T08:34:35.758Z|00021|connmgr|INFO|br-ethernet: added service controller "punix:C:\ProgramData\openvswitch\/br-ethernet.mgmt" 2020-11-04T08:34:35.765Z|00022|bridge|INFO|ovs-vswitchd (Open vSwitch) 2.7.0 2020-11-04T08:34:45.650Z|00023|memory|INFO|10280 kB peak resident set size after 10.0 seconds 2020-11-04T08:34:45.650Z|00024|memory|INFO|handlers:4 ports:2 revalidators:2 rules:5 udpif keys:73 2020-11-04T08:44:15.960Z|00025|bridge|INFO|bridge br-ethernet: deleted interface br-ethernet on port 65534 2020-11-04T08:44:15.960Z|00026|bridge|INFO|bridge br-ethernet: deleted interface Ethernet on port 1