Message | Id | Version | Qualifiers | Level | Task | Opcode | Keywords | RecordId | ProviderName | ProviderId | LogName | ProcessId | ThreadId | MachineName | UserId | TimeCreated | ActivityId | RelatedActivityId | ContainerLog | MatchedQueryIds | Bookmark | LevelDisplayName | OpcodeDisplayName | TaskDisplayName | KeywordsDisplayNames | Properties |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f1781
Analysis symbol:
Rechecking for solution: 0
Report Id: df1f780c-f04a-4e8a-adb3-b188eec20c4c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 634 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:54:01 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f1648
Analysis symbol:
Rechecking for solution: 0
Report Id: a151f882-27b7-406d-8d41-3c7eaa202f64
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 633 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:54:00 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f154e
Analysis symbol:
Rechecking for solution: 0
Report Id: bb235e40-5660-49cf-a15c-4d8918f1afe8
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 632 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:54:00 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f1435
Analysis symbol:
Rechecking for solution: 0
Report Id: 8423fcea-a056-410f-a053-454dbfb516e0
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 631 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:54:00 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f130c
Analysis symbol:
Rechecking for solution: 0
Report Id: 8ea5d041-0a5c-447d-93de-f9bba3a2ba61
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 630 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:54:00 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f1202
Analysis symbol:
Rechecking for solution: 0
Report Id: 52a35240-d1e4-4d62-a76b-696012ba3c43
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 629 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f10d9
Analysis symbol:
Rechecking for solution: 0
Report Id: 127f5582-9f45-4910-9200-7a3164a4b95f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 628 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0ec6
Analysis symbol:
Rechecking for solution: 0
Report Id: 37614a0d-f623-4482-95de-ec5972853c97
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 627 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0cd2
Analysis symbol:
Rechecking for solution: 0
Report Id: 51ed70ce-7ceb-494b-b8a7-93a2efe64fcd
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 626 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:58 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0a42
Analysis symbol:
Rechecking for solution: 0
Report Id: 797054ad-4b15-4d69-b0f7-cee8eb6137dd
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 625 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:57 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f058f
Analysis symbol:
Rechecking for solution: 0
Report Id: 6de73b34-908e-4515-93be-46bd078f6916
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 624 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0476
Analysis symbol:
Rechecking for solution: 0
Report Id: 28bbd0f2-8e8d-47f3-befc-f877e4625655
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 623 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f036c
Analysis symbol:
Rechecking for solution: 0
Report Id: 22b69618-2c40-46ed-9101-2aa846319c42
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 622 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:56 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0253
Analysis symbol:
Rechecking for solution: 0
Report Id: 700596ea-84f4-45e0-9b67-ae36ffbfe087
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 621 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:55 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0139
Analysis symbol:
Rechecking for solution: 0
Report Id: 65d7b652-8ac1-44b9-bccf-0d210f3231c9
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 620 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:55 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7f0030
Analysis symbol:
Rechecking for solution: 0
Report Id: d3436751-3d51-419f-a815-62aab4f8efe5
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 619 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:55 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7eff17
Analysis symbol:
Rechecking for solution: 0
Report Id: a909009c-f9c2-4a5a-b549-d10a5a850e28
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 618 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:55 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7efe0d
Analysis symbol:
Rechecking for solution: 0
Report Id: e67e8772-f0c5-4361-9eec-067c948eae98
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 617 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:54 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7efd03
Analysis symbol:
Rechecking for solution: 0
Report Id: 91589d0c-95f0-415d-bba6-9c98e5d2e987
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 616 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:54 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7efc09
Analysis symbol:
Rechecking for solution: 0
Report Id: 9f5136ac-1694-4bcc-b430-79712eab4c8b
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 615 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:54 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7efad1
Analysis symbol:
Rechecking for solution: 0
Report Id: bad50054-aff8-4517-8805-7a1171bdd45a
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 614 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7ef9c7
Analysis symbol:
Rechecking for solution: 0
Report Id: 9be9e280-eef7-4da1-b542-c053314ae028
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 613 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7ef8cd
Analysis symbol:
Rechecking for solution: 0
Report Id: 94d99082-00e6-48c4-ba08-6dfba7c601ae
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 612 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7ef7b4
Analysis symbol:
Rechecking for solution: 0
Report Id: acb49839-1276-48b8-8b39-c1ab57f92d78
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 611 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7ef572
Analysis symbol:
Rechecking for solution: 0
Report Id: ee3b23bb-46ae-4b5e-a8ca-bd59c4629b67
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 610 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:52 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d7ef459
Analysis symbol:
Rechecking for solution: 0
Report Id: e8e11287-fc40-478c-a10e-5b34c112b819
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 609 | Windows Error Reporting | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:52 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 608 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-23T12:52:23Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 607 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:53:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 606 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259151 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 605 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259151)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 604 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 603 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:<none> | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 602 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
MSDTC started with the following settings:
Security Configuration (OFF = 0 and ON = 1):
Allow Remote Administrator = 0,
Network Clients = 0,
Transaction Manager Communication:
Allow Inbound Transactions = 0,
Allow Outbound Transactions = 0,
Transaction Internet Protocol (TIP) = 0,
Enable XA Transactions = 0,
Enable SNA LU 6.2 Transactions = 1,
MSDTC Communications Security = Mutual Authentication Required,
Account = NT AUTHORITY\NetworkService,
Firewall Exclusion Detected = 0
Transaction Bridge Installed = 0
Filtering Duplicate Events = 1
| 4202 | 0 | 16384 | 4 | 2 | 0 | 36028797018963968 | 601 | Microsoft-Windows-MSDTC 2 | 5d9e0020-3761-4f36-90c8-38ce6511bd12 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | TM | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 2 | 0 | | 36028797018963968 | 600 | neutron-ovs-agent | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:52:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 599 | neutron-ovs-agent | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:51:39 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 598 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:51:37 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-23T12:50:37Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 597 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:51:37 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 596 | nova-compute | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:51:37 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service has created default configuration for new user 'CBCI-760455-4\administrator' .
| 5 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 595 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:51:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 594 | cloudbase-init | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:51:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Security policy in the Group policy objects has been applied successfully. | 1704 | | 16384 | 4 | 0 | | 36028797018963968 | 593 | SceCli | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:53 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 592 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 1504 | 1912 | n-h1-760455-4.cbci-760455-4.local | S-1-5-18 | 2/22/2021 12:50:52 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 591 | cloudbase-init | | Application | | | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 590 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259153 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 589 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259153)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 588 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 587 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 586 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4.cbci-760455-4.local | | 2/22/2021 12:50:50 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 585 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 1504 | 1528 | n-h1-760455-4.cbci-760455-4.local | S-1-5-18 | 2/22/2021 12:50:49 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 584 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 1504 | 1572 | n-h1-760455-4.cbci-760455-4.local | S-1-5-18 | 2/22/2021 12:50:49 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 583 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 584 | 1740 | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:50:29 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MS DTC service is stopping. | 4111 | 0 | 16384 | 4 | 1 | 0 | 36028797018963968 | 582 | Microsoft-Windows-MSDTC | 719be4ed-e9bc-4dd8-a7cf-c85ce8e4975d | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:50:29 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | SVC | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 581 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:30:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-23T12:29:06Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 580 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:30:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 579 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:29:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259174 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 578 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:29:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 577 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:29:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 576 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:29:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=wlms.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 575 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:29:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 574 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 4364 | 2332 | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:27:02 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4ad0b
Analysis symbol:
Rechecking for solution: 0
Report Id: 9e84fa43-9f19-45c6-bacc-bd0ec874da83
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 573 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4abf1
Analysis symbol:
Rechecking for solution: 0
Report Id: 570b35dd-43a0-46ed-bc13-66fba903aff4
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 572 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4aac8
Analysis symbol:
Rechecking for solution: 0
Report Id: d7d5ea9b-79b3-478e-a40f-7b337307c67e
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 571 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a980
Analysis symbol:
Rechecking for solution: 0
Report Id: 65f96503-ec14-410e-8ab5-a7081e91cfb5
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 570 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a857
Analysis symbol:
Rechecking for solution: 0
Report Id: 34cb0f34-07b8-4e07-bd1b-03c3ff11f293
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 569 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a70f
Analysis symbol:
Rechecking for solution: 0
Report Id: 0cc8f13b-b882-4cd3-92f2-96bdc3fe826c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 568 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a5d7
Analysis symbol:
Rechecking for solution: 0
Report Id: 584704d4-c45e-4b50-b46e-621b5e04ff2f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 567 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a49e
Analysis symbol:
Rechecking for solution: 0
Report Id: 7c5d93f3-871e-46b7-a357-a544940b4428
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 566 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a347
Analysis symbol:
Rechecking for solution: 0
Report Id: a456653f-7047-40cc-92b1-8b496f7f742d
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 565 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a21e
Analysis symbol:
Rechecking for solution: 0
Report Id: decea742-44de-4095-bcea-f64874c9b7a5
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 564 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:22 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4a0b6
Analysis symbol:
Rechecking for solution: 0
Report Id: b7e39e2a-1d76-46ae-b3c8-f2127ff70727
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 563 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b49f7e
Analysis symbol:
Rechecking for solution: 0
Report Id: 58e98527-273f-4518-903f-57e9c8c92b21
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 562 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b49e45
Analysis symbol:
Rechecking for solution: 0
Report Id: 071051c7-adad-46fb-99a9-992239f398b2
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 561 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_085c9d4b
Analysis symbol:
Rechecking for solution: 0
Report Id: df1f780c-f04a-4e8a-adb3-b188eec20c4c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 560 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b49d0d
Analysis symbol:
Rechecking for solution: 0
Report Id: b6669fea-2080-4987-a933-598badd2eb6f
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 559 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x928
Faulting application start time: 0x01d70914ab4c6ea2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: df1f780c-f04a-4e8a-adb3-b188eec20c4c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 558 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11789caf
Analysis symbol:
Rechecking for solution: 0
Report Id: a151f882-27b7-406d-8d41-3c7eaa202f64
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 557 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12bc
Faulting application start time: 0x01d70914ab339d83
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a151f882-27b7-406d-8d41-3c7eaa202f64
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 556 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a789c03
Analysis symbol:
Rechecking for solution: 0
Report Id: bb235e40-5660-49cf-a15c-4d8918f1afe8
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 555 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b49bd4
Analysis symbol:
Rechecking for solution: 0
Report Id: bb28311a-1729-4fae-b007-18e7c9871ebf
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 554 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x9f8
Faulting application start time: 0x01d70914ab19812c
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: bb235e40-5660-49cf-a15c-4d8918f1afe8
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 553 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10b89b57
Analysis symbol:
Rechecking for solution: 0
Report Id: 8423fcea-a056-410f-a053-454dbfb516e0
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 552 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1008
Faulting application start time: 0x01d70914ab011b3e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 8423fcea-a056-410f-a053-454dbfb516e0
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 551 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b49abb
Analysis symbol:
Rechecking for solution: 0
Report Id: b7e503f4-6ed7-4a06-bae2-4fe648c16944
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 550 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12c89abb
Analysis symbol:
Rechecking for solution: 0
Report Id: 8ea5d041-0a5c-447d-93de-f9bba3a2ba61
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 549 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12cc
Faulting application start time: 0x01d70914aae75d28
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 8ea5d041-0a5c-447d-93de-f9bba3a2ba61
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 548 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_102c9a00
Analysis symbol:
Rechecking for solution: 0
Report Id: 52a35240-d1e4-4d62-a76b-696012ba3c43
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 547 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x368
Faulting application start time: 0x01d70914aacaaf77
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 52a35240-d1e4-4d62-a76b-696012ba3c43
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 546 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b499a2
Analysis symbol:
Rechecking for solution: 0
Report Id: f154331c-318a-4913-aef2-db215bec9d00
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 545 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:20 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13409954
Analysis symbol:
Rechecking for solution: 0
Report Id: 127f5582-9f45-4910-9200-7a3164a4b95f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 544 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x89c
Faulting application start time: 0x01d70914aab07c05
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 127f5582-9f45-4910-9200-7a3164a4b95f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 543 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_100898a8
Analysis symbol:
Rechecking for solution: 0
Report Id: 37614a0d-f623-4482-95de-ec5972853c97
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 542 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4985a
Analysis symbol:
Rechecking for solution: 0
Report Id: 50d46e8b-ee90-4270-9f75-6aa33e2f3603
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 541 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x119c
Faulting application start time: 0x01d70914aa989642
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 37614a0d-f623-4482-95de-ec5972853c97
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 540 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_108c97fc
Analysis symbol:
Rechecking for solution: 0
Report Id: 51ed70ce-7ceb-494b-b8a7-93a2efe64fcd
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 539 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11c4
Faulting application start time: 0x01d70914aa7c3439
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 51ed70ce-7ceb-494b-b8a7-93a2efe64fcd
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 538 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b496e3
Analysis symbol:
Rechecking for solution: 0
Report Id: f68507d7-fb15-4cdb-b07a-ddcdc702586c
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 537 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13709740
Analysis symbol:
Rechecking for solution: 0
Report Id: 797054ad-4b15-4d69-b0f7-cee8eb6137dd
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 536 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x2e4
Faulting application start time: 0x01d70914aa62678b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 797054ad-4b15-4d69-b0f7-cee8eb6137dd
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 535 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10589695
Analysis symbol:
Rechecking for solution: 0
Report Id: 6de73b34-908e-4515-93be-46bd078f6916
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 534 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xa00
Faulting application start time: 0x01d70914aa479366
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 6de73b34-908e-4515-93be-46bd078f6916
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 533 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_076095f8
Analysis symbol:
Rechecking for solution: 0
Report Id: 28bbd0f2-8e8d-47f3-befc-f877e4625655
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 532 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4959b
Analysis symbol:
Rechecking for solution: 0
Report Id: f5079658-9056-4d9e-a4bd-482c17e8c62b
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 531 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x7fc
Faulting application start time: 0x01d70914aa2be109
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 28bbd0f2-8e8d-47f3-befc-f877e4625655
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 530 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bac952d
Analysis symbol:
Rechecking for solution: 0
Report Id: 22b69618-2c40-46ed-9101-2aa846319c42
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 529 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1010
Faulting application start time: 0x01d70914aa10c1ed
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 22b69618-2c40-46ed-9101-2aa846319c42
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 528 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_01689491
Analysis symbol:
Rechecking for solution: 0
Report Id: 700596ea-84f4-45e0-9b67-ae36ffbfe087
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 527 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b49462
Analysis symbol:
Rechecking for solution: 0
Report Id: 885114ac-bb40-4130-91dd-92e48600589e
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 526 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1364
Faulting application start time: 0x01d70914a9f72570
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 700596ea-84f4-45e0-9b67-ae36ffbfe087
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 525 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_120893f5
Analysis symbol:
Rechecking for solution: 0
Report Id: 65d7b652-8ac1-44b9-bccf-0d210f3231c9
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 524 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x548
Faulting application start time: 0x01d70914a9de8204
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 65d7b652-8ac1-44b9-bccf-0d210f3231c9
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 523 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0bf09349
Analysis symbol:
Rechecking for solution: 0
Report Id: d3436751-3d51-419f-a815-62aab4f8efe5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 522 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12ac
Faulting application start time: 0x01d70914a9c5a656
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d3436751-3d51-419f-a815-62aab4f8efe5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 521 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b4929d
Analysis symbol:
Rechecking for solution: 0
Report Id: 9d1de1c3-abd3-4320-885f-bc4c982f7a90
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 520 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e60927e
Analysis symbol:
Rechecking for solution: 0
Report Id: a909009c-f9c2-4a5a-b549-d10a5a850e28
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 519 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x11e0
Faulting application start time: 0x01d70914a9a8c804
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a909009c-f9c2-4a5a-b549-d10a5a850e28
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 518 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_124891e1
Analysis symbol:
Rechecking for solution: 0
Report Id: e67e8772-f0c5-4361-9eec-067c948eae98
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 517 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:18 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x107c
Faulting application start time: 0x01d70914a98df5bc
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e67e8772-f0c5-4361-9eec-067c948eae98
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 516 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13bc9126
Analysis symbol:
Rechecking for solution: 0
Report Id: 91589d0c-95f0-415d-bba6-9c98e5d2e987
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 515 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11b490e7
Analysis symbol:
Rechecking for solution: 0
Report Id: 7cc2303b-cb93-450f-b511-890f02707f45
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 514 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1308
Faulting application start time: 0x01d70914a9704f53
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 91589d0c-95f0-415d-bba6-9c98e5d2e987
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 513 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10f4907a
Analysis symbol:
Rechecking for solution: 0
Report Id: 9f5136ac-1694-4bcc-b430-79712eab4c8b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 512 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x5c0
Faulting application start time: 0x01d70914a955a1f2
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9f5136ac-1694-4bcc-b430-79712eab4c8b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 511 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03508faf
Analysis symbol:
Rechecking for solution: 0
Report Id: bad50054-aff8-4517-8805-7a1171bdd45a
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 510 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x694
Faulting application start time: 0x01d70914a93ad091
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: bad50054-aff8-4517-8805-7a1171bdd45a
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 509 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_043c8f13
Analysis symbol:
Rechecking for solution: 0
Report Id: 9be9e280-eef7-4da1-b542-c053314ae028
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 508 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12b0
Faulting application start time: 0x01d70914a91f069a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9be9e280-eef7-4da1-b542-c053314ae028
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 507 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0d548e76
Analysis symbol:
Rechecking for solution: 0
Report Id: 94d99082-00e6-48c4-ba08-6dfba7c601ae
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 506 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x13f4
Faulting application start time: 0x01d70914a906b3db
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 94d99082-00e6-48c4-ba08-6dfba7c601ae
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 505 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:17 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13988dcb
Analysis symbol:
Rechecking for solution: 0
Report Id: acb49839-1276-48b8-8b39-c1ab57f92d78
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 504 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x688
Faulting application start time: 0x01d70914a8ee491a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: acb49839-1276-48b8-8b39-c1ab57f92d78
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 503 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_118c8d0f
Analysis symbol:
Rechecking for solution: 0
Report Id: ee3b23bb-46ae-4b5e-a8ca-bd59c4629b67
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 502 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x8e4
Faulting application start time: 0x01d70914a8d17163
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: ee3b23bb-46ae-4b5e-a8ca-bd59c4629b67
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 501 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10448c63
Analysis symbol:
Rechecking for solution: 0
Report Id: e8e11287-fc40-478c-a10e-5b34c112b819
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 500 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x898
Faulting application start time: 0x01d70914a8b91296
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: e8e11287-fc40-478c-a10e-5b34c112b819
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 499 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_03dc8ba8
Analysis symbol:
Rechecking for solution: 0
Report Id: 9e84fa43-9f19-45c6-bacc-bd0ec874da83
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 498 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x13a8
Faulting application start time: 0x01d70914a89ab132
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9e84fa43-9f19-45c6-bacc-bd0ec874da83
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 497 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket 1574860150864349556, type 5
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_02f48aec
Analysis symbol:
Rechecking for solution: 0
Report Id: 0833ee16-9546-438a-a43a-2f875ffff1ad
Report Status: 0
Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974 | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 496 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11408b0b
Analysis symbol:
Rechecking for solution: 0
Report Id: 570b35dd-43a0-46ed-bc13-66fba903aff4
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 495 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x127c
Faulting application start time: 0x01d70914a881e151
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 570b35dd-43a0-46ed-bc13-66fba903aff4
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 494 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0fc08a60
Analysis symbol:
Rechecking for solution: 0
Report Id: d7d5ea9b-79b3-478e-a40f-7b337307c67e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 493 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x214
Faulting application start time: 0x01d70914a8699976
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: d7d5ea9b-79b3-478e-a40f-7b337307c67e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 492 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:16 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_121089c3
Analysis symbol:
Rechecking for solution: 0
Report Id: 65f96503-ec14-410e-8ab5-a7081e91cfb5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 491 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xf00
Faulting application start time: 0x01d70914a84f2fca
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 65f96503-ec14-410e-8ab5-a7081e91cfb5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 490 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ec88917
Analysis symbol:
Rechecking for solution: 0
Report Id: 34cb0f34-07b8-4e07-bd1b-03c3ff11f293
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 489 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x121c
Faulting application start time: 0x01d70914a83688a6
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 34cb0f34-07b8-4e07-bd1b-03c3ff11f293
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 488 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0ba4886c
Analysis symbol:
Rechecking for solution: 0
Report Id: 0cc8f13b-b882-4cd3-92f2-96bdc3fe826c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 487 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x101c
Faulting application start time: 0x01d70914a81b6cdc
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0cc8f13b-b882-4cd3-92f2-96bdc3fe826c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 486 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_048087cf
Analysis symbol:
Rechecking for solution: 0
Report Id: 584704d4-c45e-4b50-b46e-621b5e04ff2f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 485 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xf04
Faulting application start time: 0x01d70914a8034876
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 584704d4-c45e-4b50-b46e-621b5e04ff2f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 484 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_00a08714
Analysis symbol:
Rechecking for solution: 0
Report Id: 7c5d93f3-871e-46b7-a357-a544940b4428
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 483 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x115c
Faulting application start time: 0x01d70914a7ea001d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7c5d93f3-871e-46b7-a357-a544940b4428
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 482 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08f88658
Analysis symbol:
Rechecking for solution: 0
Report Id: a456653f-7047-40cc-92b1-8b496f7f742d
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 481 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x638
Faulting application start time: 0x01d70914a7c78eda
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: a456653f-7047-40cc-92b1-8b496f7f742d
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 480 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0590859d
Analysis symbol:
Rechecking for solution: 0
Report Id: decea742-44de-4095-bcea-f64874c9b7a5
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 479 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xbe0
Faulting application start time: 0x01d70914a7af5f7d
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: decea742-44de-4095-bcea-f64874c9b7a5
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 478 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08788501
Analysis symbol:
Rechecking for solution: 0
Report Id: b7e39e2a-1d76-46ae-b3c8-f2127ff70727
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 477 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xb60
Faulting application start time: 0x01d70914a7979f6f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b7e39e2a-1d76-46ae-b3c8-f2127ff70727
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 476 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_04248455
Analysis symbol:
Rechecking for solution: 0
Report Id: 58e98527-273f-4518-903f-57e9c8c92b21
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 475 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x5d8
Faulting application start time: 0x01d70914a77ec56f
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 58e98527-273f-4518-903f-57e9c8c92b21
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 474 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_007883a9
Analysis symbol:
Rechecking for solution: 0
Report Id: 071051c7-adad-46fb-99a9-992239f398b2
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 473 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x878
Faulting application start time: 0x01d70914a76487be
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 071051c7-adad-46fb-99a9-992239f398b2
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 472 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e4c830d
Analysis symbol:
Rechecking for solution: 0
Report Id: b6669fea-2080-4987-a933-598badd2eb6f
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 471 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x116c
Faulting application start time: 0x01d70914a74acebf
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b6669fea-2080-4987-a933-598badd2eb6f
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 470 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13b08261
Analysis symbol:
Rechecking for solution: 0
Report Id: bb28311a-1729-4fae-b007-18e7c9871ebf
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 469 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x4fc
Faulting application start time: 0x01d70914a732fd38
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: bb28311a-1729-4fae-b007-18e7c9871ebf
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 468 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:14 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134481c4
Analysis symbol:
Rechecking for solution: 0
Report Id: b7e503f4-6ed7-4a06-bae2-4fe648c16944
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 467 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1340
Faulting application start time: 0x01d70914a71aa355
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: b7e503f4-6ed7-4a06-bae2-4fe648c16944
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 466 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_113c8128
Analysis symbol:
Rechecking for solution: 0
Report Id: f154331c-318a-4913-aef2-db215bec9d00
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 465 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1174
Faulting application start time: 0x01d70914a702d2b7
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f154331c-318a-4913-aef2-db215bec9d00
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 464 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e48806d
Analysis symbol:
Rechecking for solution: 0
Report Id: 50d46e8b-ee90-4270-9f75-6aa33e2f3603
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 463 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xa18
Faulting application start time: 0x01d70914a6e76d86
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 50d46e8b-ee90-4270-9f75-6aa33e2f3603
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 462 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13987fd0
Analysis symbol:
Rechecking for solution: 0
Report Id: f68507d7-fb15-4cdb-b07a-ddcdc702586c
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 461 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1098
Faulting application start time: 0x01d70914a6ce4aeb
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f68507d7-fb15-4cdb-b07a-ddcdc702586c
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 460 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?22T12:17:07.023346900Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 459 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 1296 | 4916 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_123c7f25
Analysis symbol:
Rechecking for solution: 0
Report Id: f5079658-9056-4d9e-a4bd-482c17e8c62b
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 458 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x119c
Faulting application start time: 0x01d70914a6b1afe7
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: f5079658-9056-4d9e-a4bd-482c17e8c62b
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 457 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13e07e59
Analysis symbol:
Rechecking for solution: 0
Report Id: 885114ac-bb40-4130-91dd-92e48600589e
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 456 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:13 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0xe84
Faulting application start time: 0x01d70914a694e87a
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 885114ac-bb40-4130-91dd-92e48600589e
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 455 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f447dbd
Analysis symbol:
Rechecking for solution: 0
Report Id: 9d1de1c3-abd3-4320-885f-bc4c982f7a90
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 454 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x12e4
Faulting application start time: 0x01d70914a67ba951
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 9d1de1c3-abd3-4320-885f-bc4c982f7a90
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 453 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13cc7d11
Analysis symbol:
Rechecking for solution: 0
Report Id: 7cc2303b-cb93-450f-b511-890f02707f45
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 452 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1348
Faulting application start time: 0x01d70914a662b69e
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 7cc2303b-cb93-450f-b511-890f02707f45
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 451 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Fault bucket , type 0
Event Name: BEX64
Response: Not available
Cab Id: 0
Problem signature:
P1: ovs-vswitchd.exe
P2: 0.0.0.0
P3: 5f4ce7f4
P4: ovs-vswitchd.exe
P5: 0.0.0.0
P6: 5f4ce7f4
P7: 00000000001ed4e4
P8: c0000409
P9: 0000000000000007
P10:
Attached files:
These files may be available here:
C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0eec7c75
Analysis symbol:
Rechecking for solution: 0
Report Id: 0833ee16-9546-438a-a43a-2f875ffff1ad
Report Status: 4
Hashed bucket: | 1001 | | 0 | 4 | 0 | | 36028797018963968 | 450 | Windows Error Reporting | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4112. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 449 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 448 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 447 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4
Exception code: 0xc0000409
Fault offset: 0x00000000001ed4e4
Faulting process id: 0x1158
Faulting application start time: 0x01d70914a615645b
Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe
Report Id: 0833ee16-9546-438a-a43a-2f875ffff1ad
Faulting package full name:
Faulting package-relative application ID: | 1000 | | 0 | 2 | 100 | | 36028797018963968 | 446 | Application Error | | Application | | | n-h1-760455-4 | | 2/22/2021 12:17:12 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | Info | Application Crashing Events | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?22T12:17:07.023346900Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 445 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 1296 | 2660 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:17:07 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root list with effective date: ?Friday, ?January ?15, ?2021 12:42:37 AM. | 4111 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 444 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 443 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 442 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 441 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 440 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 439 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 438 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 437 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4109 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 436 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1880 | n-h1-760455-4 | | 2/22/2021 12:17:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4112. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 435 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:17:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 434 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1720 | n-h1-760455-4 | | 2/22/2021 12:17:00 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?22T12:08:24.589290500Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 433 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4296 | 2684 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4568. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 432 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:08:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 431 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 430 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:25 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?22T12:08:24.589290500Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 429 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4296 | 1464 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending session 0 started ?2021?-?02?-?22T12:08:23.976815300Z. | 10001 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 428 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4296 | 2684 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?22T12:08:23.976815300Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 427 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 4296 | 2004 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4568. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 426 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4568. | 1042 | | 0 | 4 | 0 | | 36028797018963968 | 425 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:08:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0. | 1033 | | 0 | 4 | 0 | | 36028797018963968 | 424 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully. | 11707 | | 0 | 4 | 0 | | 36028797018963968 | 423 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:24 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4568. | 1040 | | 0 | 4 | 0 | | 36028797018963968 | 422 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:08:23 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0. | 1035 | | 0 | 4 | 0 | | 36028797018963968 | 421 | MsiInstaller | | Application | | | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:08:15 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?22T12:07:35.633363900Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 420 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3856 | 2236 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:07:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Starting session 0 - ?2021?-?02?-?22T12:07:35.631205900Z. | 10000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 419 | Microsoft-Windows-RestartManager | 0888e5ef-9b98-4695-979d-e92ce4247224 | Application | 3856 | 2236 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1001 | 2/22/2021 12:07:35 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 418 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1696 | n-h1-760455-4 | | 2/22/2021 12:06:51 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service. | 1000 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 417 | Microsoft-Windows-LoadPerf | 122ee297-bb47-41ae-b265-1ca8d1886d40 | Application | 2416 | 2420 | n-h1-760455-4 | S-1-5-18 | 2/22/2021 12:04:48 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 416 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully scheduled Software Protection service for re-start at 2021-02-23T12:02:36Z. Reason: TBL. | 16384 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 415 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:36 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 414 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/08/21:12:03:05;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 413 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:06 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 412 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Time-based license remaining validity time 259200 minutes. | 1037 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 411 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 410 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 409 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
These policies are being excluded since they are only defined with override-only attribute.
Policy Names=(Security-SPP-Reserved-EnableNotificationMode)
App Id=55c92734-d682-4d71-983e-d6ec3f16059f
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1033 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 408 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 407 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Validity period has been started. Validity minutes=259200 Grace type=9. | 1036 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 406 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:05 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MSA client has been successfully triggered to update the Device License | 12311 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 405 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:04 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f} | 12304 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 404 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:04 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f | 12305 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 403 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:04 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection ended.
| 20489 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 402 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:03 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 401 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:03 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check passed.
| 20482 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 400 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:02 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Health check initiated.
| 20481 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 399 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:01 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine validation data collection started.
| 20488 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 398 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:03:00 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS.
| 1067 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 397 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:02:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE}
License Id=3830c1b1-5d54-4ae2-8bac-db83e9cb019e | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 396 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:02:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has successfully installed the license.
License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC}
License Id=f921c215-8c3f-4bbc-acf1-5353cfd17cf7 | 1004 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 395 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:02:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Acquisition of End User License was successful.
Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 | 1013 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 394 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:02:59 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 393 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1712 | n-h1-760455-4 | | 2/22/2021 12:02:57 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/03/04:11:58:55;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 392 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:02:55 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
MSDTC started with the following settings:
Security Configuration (OFF = 0 and ON = 1):
Allow Remote Administrator = 0,
Network Clients = 0,
Transaction Manager Communication:
Allow Inbound Transactions = 0,
Allow Outbound Transactions = 0,
Transaction Internet Protocol (TIP) = 0,
Enable XA Transactions = 0,
Enable SNA LU 6.2 Transactions = 1,
MSDTC Communications Security = Mutual Authentication Required,
Account = NT AUTHORITY\NetworkService,
Firewall Exclusion Detected = 0
Transaction Bridge Installed = 0
Filtering Duplicate Events = 1
| 4202 | 0 | 16384 | 4 | 2 | 0 | 36028797018963968 | 391 | Microsoft-Windows-MSDTC 2 | 5d9e0020-3761-4f36-90c8-38ce6511bd12 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:01:37 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | TM | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 390 | cloudbase-init | | Application | | | n-h1-760455-4 | | 2/22/2021 12:00:33 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 389 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:00:21 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied.
.
| 1534 | 0 | | 3 | 0 | 0 | -9223372036854775808 | 388 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 584 | 2208 | n-h1-760455-4 | S-1-5-21-3810923475-2229294296-1417492202-1000 | 2/22/2021 12:00:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service failed to create default configuration for new user 'N-H1-760455-4\Admin' in response to user profile creation. Error code 0x80070005.
Access is denied.
. | 6 | 0 | 49152 | 2 | 0 | 0 | 36028797018963968 | 387 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 12:00:19 PM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Error | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
| 0 | | 0 | 4 | 0 | | 36028797018963968 | 386 | cloudbase-init | | Application | | | n-h1-760455-4 | | 2/22/2021 11:59:41 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | | | | | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Search Service has created default configuration for new user 'N-H1-760455-4\cloudbase-init' .
| 5 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 385 | Microsoft-Windows-Search-ProfileNotify | fc6f77dd-769a-470e-bcf9-1b6555a118be | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 11:59:39 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>. | 4097 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 384 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1344 | 1380 | n-h1-760455-4 | | 2/22/2021 11:59:38 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 383 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 584 | 544 | n-h1-760455-4 | S-1-5-18 | 2/22/2021 11:59:35 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 382 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 584 | 1108 | n-h1-760455-4 | S-1-5-18 | 2/22/2021 11:59:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 381 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 584 | 1740 | n-h1-760455-4 | S-1-5-18 | 2/22/2021 11:59:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 380 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 11:59:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 379 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 11:59:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Proof of Purchase installed successfully.
ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4
PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845 | 1016 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 378 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 11:59:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 377 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | n-h1-760455-4 | | 2/22/2021 11:59:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 376 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 544 | 1488 | WIN-5T344G8GM1H | S-1-5-18 | 2/22/2021 11:59:03 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has stopped.
| 903 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 375 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 2/22/2021 11:59:03 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de}
Writer Name: Microsoft Hyper-V VSS Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 374 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/22/2021 11:58:14 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM. | 4112 | 0 | 0 | 4 | 0 | 0 | -9187343239835811840 | 373 | Microsoft-Windows-CAPI2 | 5bbca4a8-b209-48dc-a8c7-b23d3e5216fb | Application | 1736 | 1824 | WIN-5T344G8GM1H | | 2/22/2021 11:58:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service subsystems initialized successfully | 5617 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 372 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 544 | 1856 | WIN-5T344G8GM1H | S-1-5-18 | 2/22/2021 11:58:04 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows Management Instrumentation Service started sucessfully | 5615 | 2 | | 4 | 0 | 0 | -9223372036854775808 | 371 | Microsoft-Windows-WMI | 1edeee53-0afe-4609-b846-d8c0b2075b1f | Application | 544 | 1672 | WIN-5T344G8GM1H | S-1-5-18 | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has started successfully.
| 1531 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 370 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 544 | 1488 | WIN-5T344G8GM1H | S-1-5-18 | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f}
Writer Name: Shadow Copy Optimization Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 369 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4}
Writer Name: ASR Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 368 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f}
Writer Name: COM+ REGDB Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 367 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup.
Operation:
Initializing Writer
Context:
Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485}
Writer Name: Registry Writer | 8212 | | 0 | 4 | 0 | | 36028797018963968 | 366 | VSS | | Application | | | WIN-5T344G8GM1H | | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog. | 4625 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 365 | Microsoft-Windows-EventSystem | 899daace-4868-4295-afcd-9eb8fb497561 | Application | 0 | 0 | WIN-GNOMB1A65I6 | | 2/22/2021 11:58:02 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The User Profile Service has stopped.
| 1532 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 364 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 1228 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:13 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required.
DETAIL -
9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500:
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore
Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main
Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners
Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children
Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security
| 1530 | 0 | | 4 | 0 | 0 | -9223372036854775808 | 363 | Microsoft-Windows-User Profiles Service | 89b1e9f0-5aff-44a6-9b44-0a07a7ce5845 | Application | 976 | 3432 | WIN-5T344G8GM1H | S-1-5-18 | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | Info | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The winlogon notification subscriber <SessionEnv> failed a notification event. | 6001 | 0 | 32768 | 3 | 0 | 0 | 36028797018963968 | 362 | Microsoft-Windows-Winlogon | dbe9b383-7cf3-4331-91cc-a3cb16a3b538 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:12 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Warning | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
SLUI.exe was launched with the following command-line parameters:
RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent | 8197 | 0 | 49152 | 4 | 0 | 0 | 36028797018963968 | 361 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The rules engine successfully re-evaluated the schedule.
Kernel policies:
Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448 | 8230 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 360 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 359 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining. | 12306 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 358 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has started.
10.0.14393.351 | 902 | 0 | 16384 | 0 | 0 | 0 | 36028797018963968 | 357 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service has completed licensing status check.
Application Id=55c92734-d682-4d71-983e-d6ec3f16059f
Licensing Status=
1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])]
| 1003 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 356 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Grace period has been started. Grace days=10 Grace type=6. | 1025 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 355 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500 | 1034 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 354 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The hardware has changed. | 1024 | 0 | 32768 | 4 | 0 | 0 | 36028797018963968 | 353 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:10 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Hardware has changed from previous boot.
AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4. | 1040 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 352 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
Initialization status for service objects.
C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000
C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000
| 1066 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 351 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The Software Protection service is starting.
Parameters:caller=Sysprep.exe | 900 | 0 | 16384 | 4 | 0 | 0 | 36028797018963968 | 350 | Microsoft-Windows-Security-SPP | e23b33b0-c8c9-472c-a5f9-f2bdfea0f156 | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:48:09 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |
The MS DTC service is stopping. | 4111 | 0 | 16384 | 4 | 1 | 0 | 36028797018963968 | 349 | Microsoft-Windows-MSDTC | 719be4ed-e9bc-4dd8-a7cf-c85ce8e4975d | Application | 0 | 0 | WIN-5T344G8GM1H | | 1/19/2018 9:47:34 AM | | | application | System.UInt32[] | System.Diagnostics.Eventing.Reader.EventBookmark | Information | | SVC | System.Collections.ObjectModel.ReadOnlyCollection`1[System.String] | System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty] |