MessageIdVersionQualifiersLevelTaskOpcodeKeywordsRecordIdProviderNameProviderIdLogNameProcessIdThreadIdMachineNameUserIdTimeCreatedActivityIdRelatedActivityIdContainerLogMatchedQueryIdsBookmarkLevelDisplayNameOpcodeDisplayNameTaskDisplayNameKeywordsDisplayNamesProperties
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required. DETAIL - 1 user registry handles leaked from \Registry\User\S-1-5-21-2621301999-2889145742-3403824237-1001: Process 2428 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-2621301999-2889145742-3403824237-1001\SOFTWARE\Policies\Microsoft\Windows\DataCollection 15300400-9223372036854775808666Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application15042496n-h2-705657-14.cbci-705657-14.localS-1-5-181/28/2021 2:37:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968665Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:37:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T14:36:22Z. Reason: TBL.1638401638440036028797018963968664Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:37:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968663Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:36:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259041 minutes.103703276840036028797018963968662Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:36:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259041)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968661Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:36:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968660Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968659Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968658Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:07:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T14:06:21Z. Reason: TBL.1638401638440036028797018963968657Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:07:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968656Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259071 minutes.103703276840036028797018963968655Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259071)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968654Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968653Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968652Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 2:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968651Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:37:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T13:36:21Z. Reason: TBL.1638401638440036028797018963968650Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:37:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968649Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259101 minutes.103703276840036028797018963968648Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259101)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968647Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968646Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968645Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968644Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:07:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T13:06:21Z. Reason: TBL.1638401638440036028797018963968643Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:07:21 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968642Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259131 minutes.103703276840036028797018963968641Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259131)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968640Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968639Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:06:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968638Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 1:06:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808637Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application3540708n-h2-705657-14.cbci-705657-14.localS-1-5-181/28/2021 12:44:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1fae Analysis symbol: Rechecking for solution: 0 Report Id: 36cb8872-4bfa-4108-8c43-0b3231ddf9c4 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968636Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1df9 Analysis symbol: Rechecking for solution: 0 Report Id: e227bd1c-5521-45d8-8883-34979eba3a2e Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968635Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:04 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1c34 Analysis symbol: Rechecking for solution: 0 Report Id: d4ba5ffc-2df4-497a-bd6f-e35bfdc82c3a Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968634Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1a6f Analysis symbol: Rechecking for solution: 0 Report Id: 7f3cc0ef-5d03-4db8-9f08-b18004172965 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968633Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b18b9 Analysis symbol: Rechecking for solution: 0 Report Id: 52d7c5ff-7eec-4d65-804d-44a952f0944d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968632Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1713 Analysis symbol: Rechecking for solution: 0 Report Id: 12d39d2e-25e1-466e-b7c8-bf63a64990d5 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968631Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:02 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b158d Analysis symbol: Rechecking for solution: 0 Report Id: ffa42e39-9007-4888-b063-4b15905adf1d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968630Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1425 Analysis symbol: Rechecking for solution: 0 Report Id: a226764b-1138-4012-bae1-9952bc3ce1a1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968629Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b12cd Analysis symbol: Rechecking for solution: 0 Report Id: 6a13db54-c1fd-4e38-8800-446f819df098 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968628Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:01 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b1156 Analysis symbol: Rechecking for solution: 0 Report Id: 05916e2c-835c-459a-990d-23a40c9916d9 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968627Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0fd0 Analysis symbol: Rechecking for solution: 0 Report Id: 10315762-8442-48a9-985e-ad1cddb48a1b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968626Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0e3a Analysis symbol: Rechecking for solution: 0 Report Id: fc53ebf8-14d9-4b95-9cac-7dcab4a6769c Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968625Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:40:00 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0c94 Analysis symbol: Rechecking for solution: 0 Report Id: 43e83268-120a-4141-9321-f5607b442e77 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968624Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0ade Analysis symbol: Rechecking for solution: 0 Report Id: 748d21af-a107-4a62-912d-2fdb918dc6d2 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968623Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:59 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0967 Analysis symbol: Rechecking for solution: 0 Report Id: 1c5b0da2-ed4e-49c6-894f-15f34e8a28bf Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968622Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b07f0 Analysis symbol: Rechecking for solution: 0 Report Id: 4433a851-2140-4edf-b58e-0bab2896cb46 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968621Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0679 Analysis symbol: Rechecking for solution: 0 Report Id: 5cf9c3be-7eb5-48af-9402-e84f06ebd173 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968620Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:58 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0512 Analysis symbol: Rechecking for solution: 0 Report Id: e6805b32-c743-4b39-a2f7-4ef8ca105ebd Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968619Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b035c Analysis symbol: Rechecking for solution: 0 Report Id: d305f097-09c4-451c-9b39-5f4e8123f125 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968618Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b01b6 Analysis symbol: Rechecking for solution: 0 Report Id: 0f635c5c-d029-4e3a-ae56-725ddbc09307 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968617Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134b0011 Analysis symbol: Rechecking for solution: 0 Report Id: a6176b28-d697-484b-a305-28356b6413b8 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968616Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134afe5b Analysis symbol: Rechecking for solution: 0 Report Id: 7db7d2c8-59ac-4042-8cd5-09ecc1a1dc1d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968615Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134afce4 Analysis symbol: Rechecking for solution: 0 Report Id: a5aa42a0-b491-4977-9b8a-d835442ae1d4 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968614Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134afb5d Analysis symbol: Rechecking for solution: 0 Report Id: 494c1f97-fb8f-4f59-af1f-af7a626e8a64 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968613Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:55 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134af998 Analysis symbol: Rechecking for solution: 0 Report Id: 872f3f93-58dc-415c-be83-4309197fe5e0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968612Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134af7e3 Analysis symbol: Rechecking for solution: 0 Report Id: 2a3afd7c-02aa-44da-a611-03238cee072b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968611Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:54 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134af63d Analysis symbol: Rechecking for solution: 0 Report Id: f58e6b91-594a-4e98-8faa-bd8f53a98f04 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968610Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134af497 Analysis symbol: Rechecking for solution: 0 Report Id: 7e43774d-e574-40e8-bc48-1c047ac5fdc1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968609Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_134af2d2 Analysis symbol: Rechecking for solution: 0 Report Id: 440df692-3841-47b9-b1d6-7f9030926959 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968608Windows Error ReportingApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968607Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T12:38:22Z. Reason: TBL.1638401638440036028797018963968606Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:39:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968605Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:38:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259159 minutes.103703276840036028797018963968604Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:38:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259159)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968603Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:38:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968602Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:38:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:<none>90001638440036028797018963968601Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:38:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968600Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:38:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968599neutron-ovs-agentApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:37:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968598Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:37:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T12:36:35Z. Reason: TBL.1638401638440036028797018963968597Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:37:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968596nova-computeApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:37:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'CBCI-705657-14\administrator' . 501638440036028797018963968595Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:37:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968594cloudbase-initApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:37:14 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Security policy in the Group policy objects has been applied successfully.1704163844036028797018963968593SceCliApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:52 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808592Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication15041544n-h2-705657-14.cbci-705657-14.localS-1-5-181/28/2021 12:36:51 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968591Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259161 minutes.103703276840036028797018963968590Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259161)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968589Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968588cloudbase-initApplicationn-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968587Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968586Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-14.cbci-705657-14.local1/28/2021 12:36:50 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808585Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication15041572n-h2-705657-14.cbci-705657-14.localS-1-5-181/28/2021 12:36:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808584Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application15041528n-h2-705657-14.cbci-705657-14.localS-1-5-181/28/2021 12:36:49 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808583Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5881752n-h2-705657-14S-1-5-181/28/2021 12:36:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968582Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00n-h2-705657-141/28/2021 12:36:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968581Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:24:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T12:23:27Z. Reason: TBL.1638401638440036028797018963968580Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:24:27 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968579Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:23:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259174 minutes.103703276840036028797018963968578Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:23:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259174)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968577Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:23:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968576Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:23:57 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=wlms.exe90001638440036028797018963968575Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 12:23:56 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808574Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application19322724n-h2-705657-14S-1-5-181/28/2021 12:18:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d978 Analysis symbol: Rechecking for solution: 0 Report Id: ed142a2a-8939-475c-b29c-136dcbc08cdb Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968573Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:43 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d7e2 Analysis symbol: Rechecking for solution: 0 Report Id: e394110d-07db-4137-9ce3-db58f4e4b157 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968572Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d62c Analysis symbol: Rechecking for solution: 0 Report Id: 88d0635c-7521-49e6-a27a-2ca1f671983b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968571Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:42 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d4a6 Analysis symbol: Rechecking for solution: 0 Report Id: 039c56d3-a9ad-4e3e-b498-7c83187817d8 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968570Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d31f Analysis symbol: Rechecking for solution: 0 Report Id: 0fb45f6a-dbce-405d-a663-2100849e7846 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968569Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d179 Analysis symbol: Rechecking for solution: 0 Report Id: d367728b-af27-4a92-8778-7ba1fd7bb246 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968568Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:41 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325d012 Analysis symbol: Rechecking for solution: 0 Report Id: ff1262f4-9347-4825-aa6d-db3ff67e4722 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968567Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325ce4d Analysis symbol: Rechecking for solution: 0 Report Id: 9f8799f5-393e-4d16-8bc9-f8278f50dc3f Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968566Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:40 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325cca7 Analysis symbol: Rechecking for solution: 0 Report Id: b3d0002f-38bf-404f-9005-424d580a2893 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968565Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325caf1 Analysis symbol: Rechecking for solution: 0 Report Id: dd9c875e-95a5-40d5-b198-1e549929aa28 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968564Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325c93c Analysis symbol: Rechecking for solution: 0 Report Id: 5db21206-d273-4fe2-9037-8bee3998a18b Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968563Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:39 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325c796 Analysis symbol: Rechecking for solution: 0 Report Id: 7bc84476-4055-4b6a-9448-afb66448e40d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968562Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325c5f0 Analysis symbol: Rechecking for solution: 0 Report Id: 9bdd6ce7-04e3-4773-b6eb-14beef0128e1 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968561Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12ddc5d1 Analysis symbol: Rechecking for solution: 0 Report Id: 36cb8872-4bfa-4108-8c43-0b3231ddf9c4 Report Status: 4 Hashed bucket: 100104036028797018963968560Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x434 Faulting application start time: 0x01d6f56e4f5318e6 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 36cb8872-4bfa-4108-8c43-0b3231ddf9c4 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968559Application ErrorApplicationn-h2-705657-141/28/2021 12:08:38 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1301c515 Analysis symbol: Rechecking for solution: 0 Report Id: e227bd1c-5521-45d8-8883-34979eba3a2e Report Status: 4 Hashed bucket: 100104036028797018963968558Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x4d8 Faulting application start time: 0x01d6f56e4f35bbde Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e227bd1c-5521-45d8-8883-34979eba3a2e Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968557Application ErrorApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325c45a Analysis symbol: Rechecking for solution: 0 Report Id: a9505d50-df8c-4203-b9f8-d124d6425808 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968556Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1195c44a Analysis symbol: Rechecking for solution: 0 Report Id: d4ba5ffc-2df4-497a-bd6f-e35bfdc82c3a Report Status: 4 Hashed bucket: 100104036028797018963968555Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x129c Faulting application start time: 0x01d6f56e4f18fd09 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d4ba5ffc-2df4-497a-bd6f-e35bfdc82c3a Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968554Application ErrorApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_10b5c37f Analysis symbol: Rechecking for solution: 0 Report Id: 7f3cc0ef-5d03-4db8-9f08-b18004172965 Report Status: 4 Hashed bucket: 100104036028797018963968553Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe6c Faulting application start time: 0x01d6f56e4ef9234c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7f3cc0ef-5d03-4db8-9f08-b18004172965 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968552Application ErrorApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0cb9c2b4 Analysis symbol: Rechecking for solution: 0 Report Id: 52d7c5ff-7eec-4d65-804d-44a952f0944d Report Status: 4 Hashed bucket: 100104036028797018963968551Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325c266 Analysis symbol: Rechecking for solution: 0 Report Id: 792c5eed-58e1-453e-914f-6f483e178940 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968550Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1380 Faulting application start time: 0x01d6f56e4edb4e9d Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 52d7c5ff-7eec-4d65-804d-44a952f0944d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968549Application ErrorApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1199c1f9 Analysis symbol: Rechecking for solution: 0 Report Id: 12d39d2e-25e1-466e-b7c8-bf63a64990d5 Report Status: 4 Hashed bucket: 100104036028797018963968548Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf74 Faulting application start time: 0x01d6f56e4ebf1fd0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 12d39d2e-25e1-466e-b7c8-bf63a64990d5 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968547Application ErrorApplicationn-h2-705657-141/28/2021 12:08:37 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f59c14d Analysis symbol: Rechecking for solution: 0 Report Id: ffa42e39-9007-4888-b063-4b15905adf1d Report Status: 4 Hashed bucket: 100104036028797018963968546Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xffc Faulting application start time: 0x01d6f56e4ea4e0f4 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ffa42e39-9007-4888-b063-4b15905adf1d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968545Application ErrorApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325c082 Analysis symbol: Rechecking for solution: 0 Report Id: 033d2748-5fbd-4efc-998d-85e4ebb223f5 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968544Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1009c082 Analysis symbol: Rechecking for solution: 0 Report Id: a226764b-1138-4012-bae1-9952bc3ce1a1 Report Status: 4 Hashed bucket: 100104036028797018963968543Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe4c Faulting application start time: 0x01d6f56e4e81d5ef Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a226764b-1138-4012-bae1-9952bc3ce1a1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968542Application ErrorApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1069bfa7 Analysis symbol: Rechecking for solution: 0 Report Id: 6a13db54-c1fd-4e38-8800-446f819df098 Report Status: 4 Hashed bucket: 100104036028797018963968541Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x73c Faulting application start time: 0x01d6f56e4e613f03 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 6a13db54-c1fd-4e38-8800-446f819df098 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968540Application ErrorApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325beeb Analysis symbol: Rechecking for solution: 0 Report Id: f9181ade-9cb4-4834-9b40-22ad29a5b59d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968539Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_070dbeeb Analysis symbol: Rechecking for solution: 0 Report Id: 05916e2c-835c-459a-990d-23a40c9916d9 Report Status: 4 Hashed bucket: 100104036028797018963968538Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1058 Faulting application start time: 0x01d6f56e4e46fc49 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 05916e2c-835c-459a-990d-23a40c9916d9 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968537Application ErrorApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0929be3f Analysis symbol: Rechecking for solution: 0 Report Id: 10315762-8442-48a9-985e-ad1cddb48a1b Report Status: 4 Hashed bucket: 100104036028797018963968536Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xaac Faulting application start time: 0x01d6f56e4e2dbf99 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 10315762-8442-48a9-985e-ad1cddb48a1b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968535Application ErrorApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_133dbda3 Analysis symbol: Rechecking for solution: 0 Report Id: fc53ebf8-14d9-4b95-9cac-7dcab4a6769c Report Status: 4 Hashed bucket: 100104036028797018963968534Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:36 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325bd55 Analysis symbol: Rechecking for solution: 0 Report Id: 04e74493-5675-4b38-9b6e-c995509fed8d Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968533Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf4c Faulting application start time: 0x01d6f56e4e154e1e Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: fc53ebf8-14d9-4b95-9cac-7dcab4a6769c Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968532Application ErrorApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0291bd07 Analysis symbol: Rechecking for solution: 0 Report Id: 43e83268-120a-4141-9321-f5607b442e77 Report Status: 4 Hashed bucket: 100104036028797018963968531Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x118c Faulting application start time: 0x01d6f56e4dfca5c0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 43e83268-120a-4141-9321-f5607b442e77 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968530Application ErrorApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1361bc5b Analysis symbol: Rechecking for solution: 0 Report Id: 748d21af-a107-4a62-912d-2fdb918dc6d2 Report Status: 4 Hashed bucket: 100104036028797018963968529Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc48 Faulting application start time: 0x01d6f56e4de33380 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 748d21af-a107-4a62-912d-2fdb918dc6d2 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968528Application ErrorApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325bbaf Analysis symbol: Rechecking for solution: 0 Report Id: ec680826-5506-44c4-9ce6-9f6377fa9105 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968527Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12b5bba0 Analysis symbol: Rechecking for solution: 0 Report Id: 1c5b0da2-ed4e-49c6-894f-15f34e8a28bf Report Status: 4 Hashed bucket: 100104036028797018963968526Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12f8 Faulting application start time: 0x01d6f56e4dc82420 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 1c5b0da2-ed4e-49c6-894f-15f34e8a28bf Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968525Application ErrorApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0a19baf4 Analysis symbol: Rechecking for solution: 0 Report Id: 4433a851-2140-4edf-b58e-0bab2896cb46 Report Status: 4 Hashed bucket: 100104036028797018963968524Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1320 Faulting application start time: 0x01d6f56e4dad798f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 4433a851-2140-4edf-b58e-0bab2896cb46 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968523Application ErrorApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e21ba48 Analysis symbol: Rechecking for solution: 0 Report Id: 5cf9c3be-7eb5-48af-9402-e84f06ebd173 Report Status: 4 Hashed bucket: 100104036028797018963968522Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12bc Faulting application start time: 0x01d6f56e4d95507a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5cf9c3be-7eb5-48af-9402-e84f06ebd173 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968521Application ErrorApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325b9cb Analysis symbol: Rechecking for solution: 0 Report Id: d1908f34-02f6-4db2-97f9-dd55ad91a507 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968520Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1175b9bb Analysis symbol: Rechecking for solution: 0 Report Id: e6805b32-c743-4b39-a2f7-4ef8ca105ebd Report Status: 4 Hashed bucket: 100104036028797018963968519Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:35 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1014 Faulting application start time: 0x01d6f56e4d7e0a88 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e6805b32-c743-4b39-a2f7-4ef8ca105ebd Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968518Application ErrorApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0061b90f Analysis symbol: Rechecking for solution: 0 Report Id: d305f097-09c4-451c-9b39-5f4e8123f125 Report Status: 4 Hashed bucket: 100104036028797018963968517Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe94 Faulting application start time: 0x01d6f56e4d6308a1 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d305f097-09c4-451c-9b39-5f4e8123f125 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968516Application ErrorApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1221b863 Analysis symbol: Rechecking for solution: 0 Report Id: 0f635c5c-d029-4e3a-ae56-725ddbc09307 Report Status: 4 Hashed bucket: 100104036028797018963968515Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x83c Faulting application start time: 0x01d6f56e4d4981bf Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0f635c5c-d029-4e3a-ae56-725ddbc09307 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968514Application ErrorApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1325b7f6 Analysis symbol: Rechecking for solution: 0 Report Id: 4c4ed07f-a75d-4f1a-bb8d-47b4acd4d7f0 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968513Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e55b7c7 Analysis symbol: Rechecking for solution: 0 Report Id: a6176b28-d697-484b-a305-28356b6413b8 Report Status: 4 Hashed bucket: 100104036028797018963968512Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1204 Faulting application start time: 0x01d6f56e4d316f8f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a6176b28-d697-484b-a305-28356b6413b8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968511Application ErrorApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_09e9b71b Analysis symbol: Rechecking for solution: 0 Report Id: 7db7d2c8-59ac-4042-8cd5-09ecc1a1dc1d Report Status: 4 Hashed bucket: 100104036028797018963968510Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10a0 Faulting application start time: 0x01d6f56e4d1768ad Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7db7d2c8-59ac-4042-8cd5-09ecc1a1dc1d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968509Application ErrorApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f59b67f Analysis symbol: Rechecking for solution: 0 Report Id: a5aa42a0-b491-4977-9b8a-d835442ae1d4 Report Status: 4 Hashed bucket: 100104036028797018963968508Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x126c Faulting application start time: 0x01d6f56e4cfc55e2 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a5aa42a0-b491-4977-9b8a-d835442ae1d4 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968507Application ErrorApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1009b5c4 Analysis symbol: Rechecking for solution: 0 Report Id: 494c1f97-fb8f-4f59-af1f-af7a626e8a64 Report Status: 4 Hashed bucket: 100104036028797018963968506Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:34 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10cc Faulting application start time: 0x01d6f56e4ce29cd0 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 494c1f97-fb8f-4f59-af1f-af7a626e8a64 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968505Application ErrorApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0479b508 Analysis symbol: Rechecking for solution: 0 Report Id: 872f3f93-58dc-415c-be83-4309197fe5e0 Report Status: 4 Hashed bucket: 100104036028797018963968504Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x9c0 Faulting application start time: 0x01d6f56e4cc50152 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 872f3f93-58dc-415c-be83-4309197fe5e0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968503Application ErrorApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e69b44d Analysis symbol: Rechecking for solution: 0 Report Id: 2a3afd7c-02aa-44da-a611-03238cee072b Report Status: 4 Hashed bucket: 100104036028797018963968502Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe90 Faulting application start time: 0x01d6f56e4ca82774 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 2a3afd7c-02aa-44da-a611-03238cee072b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968501Application ErrorApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0581b391 Analysis symbol: Rechecking for solution: 0 Report Id: f58e6b91-594a-4e98-8faa-bd8f53a98f04 Report Status: 4 Hashed bucket: 100104036028797018963968500Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x700 Faulting application start time: 0x01d6f56e4c8cad36 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f58e6b91-594a-4e98-8faa-bd8f53a98f04 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968499Application ErrorApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1281b2e5 Analysis symbol: Rechecking for solution: 0 Report Id: 7e43774d-e574-40e8-bc48-1c047ac5fdc1 Report Status: 4 Hashed bucket: 100104036028797018963968498Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc5c Faulting application start time: 0x01d6f56e4c717f31 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7e43774d-e574-40e8-bc48-1c047ac5fdc1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968497Application ErrorApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0415b239 Analysis symbol: Rechecking for solution: 0 Report Id: 440df692-3841-47b9-b1d6-7f9030926959 Report Status: 4 Hashed bucket: 100104036028797018963968496Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x116c Faulting application start time: 0x01d6f56e4c58256f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 440df692-3841-47b9-b1d6-7f9030926959 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968495Application ErrorApplicationn-h2-705657-141/28/2021 12:08:33 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0845b18d Analysis symbol: Rechecking for solution: 0 Report Id: ed142a2a-8939-475c-b29c-136dcbc08cdb Report Status: 4 Hashed bucket: 100104036028797018963968494Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xf4c Faulting application start time: 0x01d6f56e4c3eff24 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ed142a2a-8939-475c-b29c-136dcbc08cdb Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968493Application ErrorApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket 1574860150864349556, type 5 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportArchive\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1181b0e2 Analysis symbol: Rechecking for solution: 0 Report Id: 0f04d770-b79c-410e-8c84-37333070c354 Report Status: 0 Hashed bucket: 6e7d2ac1006f07a4a5db06f697300974100104036028797018963968492Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_12d9b0f1 Analysis symbol: Rechecking for solution: 0 Report Id: e394110d-07db-4137-9ce3-db58f4e4b157 Report Status: 4 Hashed bucket: 100104036028797018963968491Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xc10 Faulting application start time: 0x01d6f56e4c2602ae Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: e394110d-07db-4137-9ce3-db58f4e4b157 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968490Application ErrorApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1351b055 Analysis symbol: Rechecking for solution: 0 Report Id: 88d0635c-7521-49e6-a27a-2ca1f671983b Report Status: 4 Hashed bucket: 100104036028797018963968489Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x12b8 Faulting application start time: 0x01d6f56e4c0de1b3 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 88d0635c-7521-49e6-a27a-2ca1f671983b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968488Application ErrorApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11f9afa9 Analysis symbol: Rechecking for solution: 0 Report Id: 039c56d3-a9ad-4e3e-b498-7c83187817d8 Report Status: 4 Hashed bucket: 100104036028797018963968487Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x78c Faulting application start time: 0x01d6f56e4bf56341 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 039c56d3-a9ad-4e3e-b498-7c83187817d8 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968486Application ErrorApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_131daf1c Analysis symbol: Rechecking for solution: 0 Report Id: 0fb45f6a-dbce-405d-a663-2100849e7846 Report Status: 4 Hashed bucket: 100104036028797018963968485Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x5b8 Faulting application start time: 0x01d6f56e4bdc3b02 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0fb45f6a-dbce-405d-a663-2100849e7846 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968484Application ErrorApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0b71ae71 Analysis symbol: Rechecking for solution: 0 Report Id: d367728b-af27-4a92-8778-7ba1fd7bb246 Report Status: 4 Hashed bucket: 100104036028797018963968483Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1394 Faulting application start time: 0x01d6f56e4bc378ca Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d367728b-af27-4a92-8778-7ba1fd7bb246 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968482Application ErrorApplicationn-h2-705657-141/28/2021 12:08:32 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0431adc5 Analysis symbol: Rechecking for solution: 0 Report Id: ff1262f4-9347-4825-aa6d-db3ff67e4722 Report Status: 4 Hashed bucket: 100104036028797018963968481Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11e0 Faulting application start time: 0x01d6f56e4ba8e750 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ff1262f4-9347-4825-aa6d-db3ff67e4722 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968480Application ErrorApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13ddad19 Analysis symbol: Rechecking for solution: 0 Report Id: 9f8799f5-393e-4d16-8bc9-f8278f50dc3f Report Status: 4 Hashed bucket: 100104036028797018963968479Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1078 Faulting application start time: 0x01d6f56e4b905187 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9f8799f5-393e-4d16-8bc9-f8278f50dc3f Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968478Application ErrorApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_073dac6d Analysis symbol: Rechecking for solution: 0 Report Id: b3d0002f-38bf-404f-9005-424d580a2893 Report Status: 4 Hashed bucket: 100104036028797018963968477Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1088 Faulting application start time: 0x01d6f56e4b76c3e1 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: b3d0002f-38bf-404f-9005-424d580a2893 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968476Application ErrorApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_13b1abe0 Analysis symbol: Rechecking for solution: 0 Report Id: dd9c875e-95a5-40d5-b198-1e549929aa28 Report Status: 4 Hashed bucket: 100104036028797018963968475Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x11d4 Faulting application start time: 0x01d6f56e4b5e8512 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: dd9c875e-95a5-40d5-b198-1e549929aa28 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968474Application ErrorApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1221ab25 Analysis symbol: Rechecking for solution: 0 Report Id: 5db21206-d273-4fe2-9037-8bee3998a18b Report Status: 4 Hashed bucket: 100104036028797018963968473Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xeb0 Faulting application start time: 0x01d6f56e4b44a131 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 5db21206-d273-4fe2-9037-8bee3998a18b Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968472Application ErrorApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0f19aa89 Analysis symbol: Rechecking for solution: 0 Report Id: 7bc84476-4055-4b6a-9448-afb66448e40d Report Status: 4 Hashed bucket: 100104036028797018963968471Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x4e0 Faulting application start time: 0x01d6f56e4b2d1000 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 7bc84476-4055-4b6a-9448-afb66448e40d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968470Application ErrorApplicationn-h2-705657-141/28/2021 12:08:31 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1231a9ec Analysis symbol: Rechecking for solution: 0 Report Id: 9bdd6ce7-04e3-4773-b6eb-14beef0128e1 Report Status: 4 Hashed bucket: 100104036028797018963968469Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x338 Faulting application start time: 0x01d6f56e4b130b15 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 9bdd6ce7-04e3-4773-b6eb-14beef0128e1 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968468Application ErrorApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0aa9a940 Analysis symbol: Rechecking for solution: 0 Report Id: a9505d50-df8c-4203-b9f8-d124d6425808 Report Status: 4 Hashed bucket: 100104036028797018963968467Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x111c Faulting application start time: 0x01d6f56e4afa211a Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: a9505d50-df8c-4203-b9f8-d124d6425808 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968466Application ErrorApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0e5da895 Analysis symbol: Rechecking for solution: 0 Report Id: 792c5eed-58e1-453e-914f-6f483e178940 Report Status: 4 Hashed bucket: 100104036028797018963968465Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10bc Faulting application start time: 0x01d6f56e4ae286da Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 792c5eed-58e1-453e-914f-6f483e178940 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968464Application ErrorApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_08b9a7f8 Analysis symbol: Rechecking for solution: 0 Report Id: 033d2748-5fbd-4efc-998d-85e4ebb223f5 Report Status: 4 Hashed bucket: 100104036028797018963968463Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x73c Faulting application start time: 0x01d6f56e4ac9868b Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 033d2748-5fbd-4efc-998d-85e4ebb223f5 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968462Application ErrorApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2021?-?01?-?28T12:08:24.758202800Z.100010400-9223372036854775808461Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application50645108n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0989a76c Analysis symbol: Rechecking for solution: 0 Report Id: f9181ade-9cb4-4834-9b40-22ad29a5b59d Report Status: 4 Hashed bucket: 100104036028797018963968460Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0xe38 Faulting application start time: 0x01d6f56e4ab23075 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: f9181ade-9cb4-4834-9b40-22ad29a5b59d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968459Application ErrorApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0c15a6df Analysis symbol: Rechecking for solution: 0 Report Id: 04e74493-5675-4b38-9b6e-c995509fed8d Report Status: 4 Hashed bucket: 100104036028797018963968458Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x1058 Faulting application start time: 0x01d6f56e4a9af56f Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 04e74493-5675-4b38-9b6e-c995509fed8d Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968457Application ErrorApplicationn-h2-705657-141/28/2021 12:08:30 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_1281a614 Analysis symbol: Rechecking for solution: 0 Report Id: ec680826-5506-44c4-9ce6-9f6377fa9105 Report Status: 4 Hashed bucket: 100104036028797018963968456Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x704 Faulting application start time: 0x01d6f56e4a7e3b6c Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: ec680826-5506-44c4-9ce6-9f6377fa9105 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968455Application ErrorApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_0415a568 Analysis symbol: Rechecking for solution: 0 Report Id: d1908f34-02f6-4db2-97f9-dd55ad91a507 Report Status: 4 Hashed bucket: 100104036028797018963968454Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x10e4 Faulting application start time: 0x01d6f56e4a64d2e1 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: d1908f34-02f6-4db2-97f9-dd55ad91a507 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968453Application ErrorApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_11c5a4bc Analysis symbol: Rechecking for solution: 0 Report Id: 4c4ed07f-a75d-4f1a-bb8d-47b4acd4d7f0 Report Status: 4 Hashed bucket: 100104036028797018963968452Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x574 Faulting application start time: 0x01d6f56e4a4b64cd Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 4c4ed07f-a75d-4f1a-bb8d-47b4acd4d7f0 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968451Application ErrorApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Fault bucket , type 0 Event Name: BEX64 Response: Not available Cab Id: 0 Problem signature: P1: ovs-vswitchd.exe P2: 0.0.0.0 P3: 5f4ce7f4 P4: ovs-vswitchd.exe P5: 0.0.0.0 P6: 5f4ce7f4 P7: 00000000001ed4e4 P8: c0000409 P9: 0000000000000007 P10: Attached files: These files may be available here: C:\ProgramData\Microsoft\Windows\WER\ReportQueue\AppCrash_ovs-vswitchd.exe_d7c14c55585d3323f698ba0f1fe8ca781ea965f_ba3cf286_051da420 Analysis symbol: Rechecking for solution: 0 Report Id: 0f04d770-b79c-410e-8c84-37333070c354 Report Status: 4 Hashed bucket: 100104036028797018963968450Windows Error ReportingApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4536.104204036028797018963968449MsiInstallerApplicationn-h2-705657-14S-1-5-181/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Faulting application name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Faulting module name: ovs-vswitchd.exe, version: 0.0.0.0, time stamp: 0x5f4ce7f4 Exception code: 0xc0000409 Fault offset: 0x00000000001ed4e4 Faulting process id: 0x82c Faulting application start time: 0x01d6f56e4a03ad15 Faulting application path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Faulting module path: c:\Program Files\Cloudbase Solutions\Open vSwitch\bin\ovs-vswitchd.exe Report Id: 0f04d770-b79c-410e-8c84-37333070c354 Faulting package full name: Faulting package-relative application ID: 10000210036028797018963968448Application ErrorApplicationn-h2-705657-141/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorInfoApplication Crashing EventsSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Cloudbase Open vSwitch™ for Windows®. Product Version: 2.12.1. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Installation success or error status: 0.103304036028797018963968447MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Cloudbase Open vSwitch™ for Windows® -- Installation completed successfully.1170704036028797018963968446MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:08:29 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?01?-?28T12:08:24.758202800Z.100000400-9223372036854775808445Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application50641776n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:08:24 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: c:\openstack\tmp\ovs.msi. Client Process Id: 4536.104004036028797018963968444MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:08:22 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=VeriSign Universal Root Certification Authority, OU="(c) 2008 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <3679CA35668772304D30A5FB873B0FA77BB70D54>.409700400-9187343239835811840443Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13361660n-h2-705657-141/28/2021 12:08:17 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root list with effective date: ?Friday, ?January ?15, ?2021 12:42:37 AM.411100400-9187343239835811840442Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=AddTrust External CA Root, OU=AddTrust External TTP Network, O=AddTrust AB, C=SE> Sha1 thumbprint: <02FAF3E291435468607857694DF5E45B68851868>.410900400-9187343239835811840441Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=VeriSign Class 3 Public Primary Certification Authority - G5, OU="(c) 2006 VeriSign, Inc. - For authorized use only", OU=VeriSign Trust Network, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <4EB6D578499B1CCF5F581EAD56BE3D9B6744A5E5>.410900400-9187343239835811840440Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <OU=Class 3 Public Primary Certification Authority, O="VeriSign, Inc.", C=US> Sha1 thumbprint: <742C3192E607E424EB4549542BE1BBC53E6174E2>.410900400-9187343239835811840439Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.410900400-9187343239835811840438Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.410900400-9187343239835811840437Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=Baltimore CyberTrust Root, OU=CyberTrust, O=Baltimore, C=IE> Sha1 thumbprint: <D4DE20D05E66FC53FE1A50882C78DB2852CAE474>.410900400-9187343239835811840436Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto property update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.410900400-9187343239835811840435Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13363088n-h2-705657-141/28/2021 12:05:53 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2021?-?01?-?28T12:00:12.360721600Z.100010400-9223372036854775808434Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application10723196n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4348.104204036028797018963968433MsiInstallerApplicationn-h2-705657-14S-1-5-181/28/2021 12:00:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968432MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Additional Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968431MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:13 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?01?-?28T12:00:12.360721600Z.100000400-9223372036854775808430Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application10724828n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending session 0 started ?2021?-?01?-?28T12:00:11.830327300Z.100010400-9223372036854775808429Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application10723196n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?01?-?28T12:00:11.830327300Z.100000400-9223372036854775808428Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application1072504n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{B175520C-86A2-35A7-8619-86DC379688B9}v11.0.61030\packages\vcRuntimeAdditional_x86\vc_runtimeAdditional_x86.msi. Client Process Id: 4348.104004036028797018963968427MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Ending a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4348.104204036028797018963968426MsiInstallerApplicationn-h2-705657-14S-1-5-181/28/2021 12:00:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer installed the product. Product Name: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030. Product Version: 11.0.61030. Product Language: 1033. Manufacturer: Microsoft Corporation. Installation success or error status: 0.103304036028797018963968425MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Product: Microsoft Visual C++ 2012 x86 Minimum Runtime - 11.0.61030 -- Installation completed successfully.1170704036028797018963968424MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:12 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Beginning a Windows Installer transaction: C:\ProgramData\Package Cache\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}v11.0.61030\packages\vcRuntimeMinimum_x86\vc_runtimeMinimum_x86.msi. Client Process Id: 4348.104004036028797018963968423MsiInstallerApplicationn-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 12:00:11 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Installer reconfigured the product. Product Name: Cloudbase-Init 0.9.12.dev26. Product Version: 0.9.12.0. Product Language: 1033. Manufacturer: Cloudbase Solutions Srl. Reconfiguration success or error status: 0.103504036028797018963968422MsiInstallerApplicationn-h2-705657-14S-1-5-181/28/2021 12:00:03 PMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?01?-?28T11:59:26.989074800Z.100000400-9223372036854775808421Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application11603636n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 11:59:27 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Starting session 0 - ?2021?-?01?-?28T11:59:26.989074800Z.100000400-9223372036854775808420Microsoft-Windows-RestartManager0888e5ef-9b98-4695-979d-e92ce4247224Application11603636n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10011/28/2021 11:59:26 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Performance counters for the WmiApRpl (WmiApRpl) service were loaded successfully. The Record Data in the data section contains the new index values assigned to this service.10000400-9223372036854775808419Microsoft-Windows-LoadPerf122ee297-bb47-41ae-b265-1ca8d1886d40Application38805000n-h2-705657-14S-1-5-181/28/2021 11:59:19 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=GlobalSign Root CA, OU=Root CA, O=GlobalSign nv-sa, C=BE> Sha1 thumbprint: <B1BC968BD4F49D622AA89A81F2150152A41D829C>.409700400-9187343239835811840418Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13361964n-h2-705657-141/28/2021 11:58:46 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968417Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:58:05 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully scheduled Software Protection service for re-start at 2021-01-29T11:57:05Z. Reason: TBL.1638401638440036028797018963968416Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:58:05 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=379cccfb-d4e0-48fe-b0f2-0136097be147;Action=CleanupState;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;Trigger=TimerEvent819704915240036028797018963968415Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:35 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/07/27:11:57:34;LastConsumptionReason=0x4004fc04;LastNotificationId=Cleanup;LicenseState=SL_LICENSING_STATUS_LICENSED;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=379cccfb-d4e0-48fe-b0f2-0136097be147;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968414Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:35 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;Action=AutoActivate;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968413Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Time-based license remaining validity time 259200 minutes.103703276840036028797018963968412Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968411Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 [0x00000000, 1, 0], [(?)( 1 0x00000000)(?)( 2 0x00000000 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)( 9 0x00000000 180 259200)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 )] 100301638440036028797018963968410Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
These policies are being excluded since they are only defined with override-only attribute. Policy Names=(Security-SPP-Reserved-EnableNotificationMode) App Id=55c92734-d682-4d71-983e-d6ec3f16059f Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4103301638440036028797018963968409Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-Reserved-LicenseProperties Priority=100103401638440036028797018963968408Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Validity period has been started. Validity minutes=259200 Grace type=9.103601638440036028797018963968407Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MSA client has been successfully triggered to update the Device License1231101638440036028797018963968406Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successfully acquired genuine ticket for template Id {99d92734-d682-4d71-983e-d6ec3f16059f}1230401638440036028797018963968405Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:32 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine state set to genuine for application Id 55c92734-d682-4d71-983e-d6ec3f16059f1230501638440036028797018963968404Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:32 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection ended. 2048904915240036028797018963968403Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:32 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968402Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:32 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check passed. 2048204915240036028797018963968401Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:31 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Health check initiated. 2048104915240036028797018963968400Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:30 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine validation data collection started. 2048804915240036028797018963968399Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:30 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Genuine information set for application. 0x00000000, 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, SL_ACTIVATION_VALIDATION_IN_PROGRESS. 106703276840036028797018963968398Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PRIVATE} License Id=b05e909e-d619-410b-a2ef-52fdec59f78e100401638440036028797018963968397Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has successfully installed the license. License Title=XrML 2.1 License - {msft:sl/EUL/ACTIVATED/PUBLIC} License Id=6804e996-4f92-445b-bf0c-e91e47f9895b100401638440036028797018963968396Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Acquisition of End User License was successful. Sku Id=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4101301638400036028797018963968395Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root G2, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <DF3C24F9BFD666761B268073FE06D1CC8D4F82A4>.409700400-9187343239835811840394Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13361372n-h2-705657-141/28/2021 11:57:27 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;GraceEndDate=2021/02/07:11:53:24;LastConsumptionReason=0x4004f00c;LastNotificationId=NeverActivated;LicenseState=SL_LICENSING_STATUS_IN_GRACE_PERIOD;PartialProductKey=TVKQ6;ProductKeyType=Retail:TB:Eval;SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4;ruleId=31e71c49-8da7-4a2f-ad92-45d98a1c79ba;uxDifferentiator=TIMEBASED_EVAL823001638440036028797018963968393Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:57:24 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
MSDTC started with the following settings: Security Configuration (OFF = 0 and ON = 1): Allow Remote Administrator = 0, Network Clients = 0, Transaction Manager Communication: Allow Inbound Transactions = 0, Allow Outbound Transactions = 0, Transaction Internet Protocol (TIP) = 0, Enable XA Transactions = 0, Enable SNA LU 6.2 Transactions = 1, MSDTC Communications Security = Mutual Authentication Required, Account = NT AUTHORITY\NetworkService, Firewall Exclusion Detected = 0 Transaction Bridge Installed = 0 Filtering Duplicate Events = 1 420201638442036028797018963968392Microsoft-Windows-MSDTC 25d9e0020-3761-4f36-90c8-38ce6511bd12Application00n-h2-705657-141/28/2021 11:55:58 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationTMSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968391cloudbase-initApplicationn-h2-705657-141/28/2021 11:54:53 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 1 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14398)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968390Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:54:41 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Profile notification of event Create for component {DE3F3560-3032-41B4-B6CF-F703B1B95640} failed, error code is Access is denied. . 15340300-9223372036854775808389Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5882908n-h2-705657-14S-1-5-21-2621301999-2889145742-3403824237-10001/28/2021 11:54:40 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service failed to create default configuration for new user 'N-H2-705657-14\Admin' in response to user profile creation. Error code 0x80070005. Access is denied. .604915220036028797018963968388Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00n-h2-705657-141/28/2021 11:54:40 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkErrorSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
004036028797018963968387cloudbase-initApplicationn-h2-705657-141/28/2021 11:54:01 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkSystem.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Search Service has created default configuration for new user 'N-H2-705657-14\cloudbase-init' . 501638440036028797018963968386Microsoft-Windows-Search-ProfileNotifyfc6f77dd-769a-470e-bcf9-1b6555a118beApplication00n-h2-705657-141/28/2021 11:54:00 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of third-party root certificate:: Subject: <CN=DigiCert Global Root CA, OU=www.digicert.com, O=DigiCert Inc, C=US> Sha1 thumbprint: <A8985D3A65E5E5C4B2D7D66D40C6DD2FB19C5436>.409700400-9187343239835811840385Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication13361660n-h2-705657-141/28/2021 11:53:58 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808384Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5881772n-h2-705657-14S-1-5-181/28/2021 11:53:57 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808383Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication588576n-h2-705657-14S-1-5-181/28/2021 11:53:56 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808382Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5881752n-h2-705657-14S-1-5-181/28/2021 11:53:55 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 )(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14399)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968381Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:53:56 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968380Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:53:56 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Proof of Purchase installed successfully. ACID=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4 PKeyId=771fdd12-cf29-6d27-eb0d-9c7435943845101601638440036028797018963968379Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00n-h2-705657-141/28/2021 11:53:55 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog.462501638440036028797018963968378Microsoft-Windows-EventSystem899daace-4868-4295-afcd-9eb8fb497561Application00n-h2-705657-141/28/2021 11:53:55 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808377Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5321484WIN-5T344G8GM1HS-1-5-181/28/2021 11:53:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The VSS service is shutting down due to shutdown event from the Service Control Manager. 822504036028797018963968376VSSApplicationWIN-5T344G8GM1H1/28/2021 11:53:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has stopped. 90301638400036028797018963968375Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/28/2021 11:53:28 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Microsoft Hyper-V VSS Writer and ID {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {66841cd4-6ded-4f4b-8f17-fd23f8ddc3de} Writer Name: Microsoft Hyper-V VSS Writer821204036028797018963968374VSSApplicationWIN-5T344G8GM1H1/28/2021 11:52:44 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Successful auto update of disallowed certificate list with effective date: ?Thursday, ?December ?10, ?2020 9:56:46 PM.411200400-9187343239835811840373Microsoft-Windows-CAPI25bbca4a8-b209-48dc-a8c7-b23d3e5216fbApplication16521808WIN-5T344G8GM1H1/28/2021 11:52:40 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service subsystems initialized successfully56172400-9223372036854775808372Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication532680WIN-5T344G8GM1HS-1-5-181/28/2021 11:52:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows Management Instrumentation Service started sucessfully56152400-9223372036854775808371Microsoft-Windows-WMI1edeee53-0afe-4609-b846-d8c0b2075b1fApplication5321560WIN-5T344G8GM1HS-1-5-181/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has started successfully. 15310400-9223372036854775808370Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application5321484WIN-5T344G8GM1HS-1-5-181/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Shadow Copy Optimization Writer and ID {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {4dc3bdd4-ab48-4d07-adb0-3bee2926fd7f} Writer Name: Shadow Copy Optimization Writer821204036028797018963968369VSSApplicationWIN-5T344G8GM1H1/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name ASR Writer and ID {be000cbe-11fe-4426-9c58-531aa6355fc4} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {be000cbe-11fe-4426-9c58-531aa6355fc4} Writer Name: ASR Writer821204036028797018963968368VSSApplicationWIN-5T344G8GM1H1/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name COM+ REGDB Writer and ID {542da469-d3e1-473c-9f4f-7847f01fc64f} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {542da469-d3e1-473c-9f4f-7847f01fc64f} Writer Name: COM+ REGDB Writer821204036028797018963968367VSSApplicationWIN-5T344G8GM1H1/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Volume Shadow Copy Service: Writer with name Registry Writer and ID {afbab4a2-367d-4d15-a586-71dbb18f8485} attempted to subscribe during setup. Operation: Initializing Writer Context: Writer Class Id: {afbab4a2-367d-4d15-a586-71dbb18f8485} Writer Name: Registry Writer821204036028797018963968366VSSApplicationWIN-5T344G8GM1H1/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The EventSystem sub system is suppressing duplicate event log entries for a duration of 86400 seconds. The suppression timeout can be controlled by a REG_DWORD value named SuppressDuplicateDuration under the following registry key: HKLM\Software\Microsoft\EventSystem\EventLog.462501638440036028797018963968365Microsoft-Windows-EventSystem899daace-4868-4295-afcd-9eb8fb497561Application00WIN-JNRO8PMM6DO1/28/2021 11:52:33 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The User Profile Service has stopped. 15320400-9223372036854775808364Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9761228WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:13 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Windows detected your registry file is still in use by other applications or services. The file will be unloaded now. The applications or services that hold your registry file may not function properly afterwards. No user action is required. DETAIL - 9 user registry handles leaked from \Registry\User\S-1-5-21-416071247-492812682-1642729393-500: Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Parents Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore Process 312 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Policies\Microsoft\Windows\CurrentVersion\Internet Settings Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Main Process 3092 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\ActiveSync\Partners Process 764 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\System\GameConfigStore\Children Process 976 (\Device\HarddiskVolume1\Windows\System32\svchost.exe) has opened key \REGISTRY\USER\S-1-5-21-416071247-492812682-1642729393-500\SOFTWARE\Microsoft\Internet Explorer\Security 15300400-9223372036854775808363Microsoft-Windows-User Profiles Service89b1e9f0-5aff-44a6-9b44-0a07a7ce5845Application9763432WIN-5T344G8GM1HS-1-5-181/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationInfoSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The winlogon notification subscriber <SessionEnv> failed a notification event.600103276830036028797018963968362Microsoft-Windows-Winlogondbe9b383-7cf3-4331-91cc-a3cb16a3b538Application00WIN-5T344G8GM1H1/19/2018 9:48:12 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkWarningSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
SLUI.exe was launched with the following command-line parameters: RuleId=984306a1-75fc-4a6b-b3f9-8501ba26a448;Action=NotifyUser;AppId=55c92734-d682-4d71-983e-d6ec3f16059f;NotificationInterval=1440;Trigger=TimerEvent819704915240036028797018963968361Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The rules engine successfully re-evaluated the schedule. Kernel policies: Security-SPP-Action-StateData (REG_SZ) =AppId=55c92734-d682-4d71-983e-d6ec3f16059f;LastNotificationId=RebootRequired;ruleId=984306a1-75fc-4a6b-b3f9-8501ba26a448823001638440036028797018963968360Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004D302, 0, 0], [(?)(?)(?)(?)(?)(?)(?)(?)])(1 )(2 )(3 )] 100301638440036028797018963968359Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Rearm successful for AppId = 55c92734-d682-4d71-983e-d6ec3f16059f, SkuId = (null) - 5 Rearms Remaining.1230601638440036028797018963968358Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has started. 10.0.14393.35190201638400036028797018963968357Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service has completed licensing status check. Application Id=55c92734-d682-4d71-983e-d6ec3f16059f Licensing Status= 1: 9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4, 1, 0 [(0 [0xC004E003, 0, 0], [( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)( 1 0x00000000)(?)( 2 0xC004F00F 0 0 msft:rm/algorithm/hwid/4.0 0x00000000 0)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])(1 )(2 )(3 [0x00000000, 0, 1], [(?)( 1 0x00000000)( 6 0x00000000 10 14400)(?)(?)(?)( 10 0x00000000 msft:rm/algorithm/flags/1.0)(?)])] 100301638440036028797018963968356Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Grace period has been started. Grace days=10 Grace type=6.102501638440036028797018963968355Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Duplicate definition of policy found. Policy name=Security-SPP-WriteWauMarker Priority=500103401638440036028797018963968354Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The hardware has changed.102403276840036028797018963968353Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:10 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Hardware has changed from previous boot. AppId=55c92734-d682-4d71-983e-d6ec3f16059f, SkuId=9dfa8ec0-7665-4b9d-b2cb-bfc2dc37c9f4.104001638440036028797018963968352Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
Initialization status for service objects. C:\windows\system32\sppwinob.dll, msft:spp/windowsfunctionality/agent/7.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/inherited/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/phone/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:rm/algorithm/pkey/detect, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/ActionScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/TaskScheduler/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/statecollector/pkey, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/1.0, 0x00000000, 0x00000000 C:\windows\system32\sppobjs.dll, msft:spp/volume/services/kms/activationinfo/1.0, 0x00000000, 0x00000000 106601638440036028797018963968351Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The Software Protection service is starting. Parameters:caller=Sysprep.exe90001638440036028797018963968350Microsoft-Windows-Security-SPPe23b33b0-c8c9-472c-a5f9-f2bdfea0f156Application00WIN-5T344G8GM1H1/19/2018 9:48:09 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]
The MS DTC service is stopping.411101638441036028797018963968349Microsoft-Windows-MSDTC719be4ed-e9bc-4dd8-a7cf-c85ce8e4975dApplication00WIN-5T344G8GM1H1/19/2018 9:47:34 AMapplicationSystem.UInt32[]System.Diagnostics.Eventing.Reader.EventBookmarkInformationSVCSystem.Collections.ObjectModel.ReadOnlyCollection`1[System.String]System.Collections.Generic.List`1[System.Diagnostics.Eventing.Reader.EventProperty]